Features:
- Serves as the Input Interface for RTD, Thermocouple, and Millivolt Signals in FLEX Ex Systems
- Integrates Multi-Type Sensor Compatibility with Four Built-In Diagnostic Alarms
- Functions Alongside the FLEX Ex I/O System and Compatible ControlLogix/CompactLogix Platforms
The 1797-IRT8 operates as the FLEX Ex RTD/Thermocouple/mV Input Module within a FLEX Ex distributed I/O rack, providing reliable analog signal acquisition from diverse temperature and voltage sources. It continuously processes incoming signals from 8 independent input channels, converting RTD resistance values, thermocouple EMF voltages, and direct millivolt inputs into digital data for transmission through the FLEX Ex communication adapter to the host controller. Seamless integration with standard FLEX Ex power and communication modules is standard with the 1797-IRT8, and its intrinsic safety design allows direct connection to sensors installed in hazardous area locations (Zone 0, 1, or 2) without requiring additional safety barriers. The 1797-IRT8 incorporates comprehensive diagnostics and alarm generation capabilities that represent significant improvements over conventional analog input designs.
The 1797-IRT8 provides essential temperature and voltage measurement functions common to process control and monitoring applications, and is a critical component of the data acquisition path, directly affecting the accuracy and reliability of the overall control system. One 1797-IRT8 module occupies a single slot in the FLEX Ex rack and supports up to eight field device connections. The module is configured using RSNetWorx for DeviceNet or Studio 5000 software, allowing flexible scaling, alarm setpoints, and channel-specific parameterization.
For comprehensive process monitoring, the 1797-IRT8 generates four distinct alarm conditions to ensure signal integrity and system safety. In addition to standard input signal processing, the module performs continuous diagnostic monitoring across all active channels. The 1797-IRT8 executes alarm detection using internal circuitry specified in the module firmware. Using this method, the diagnostic system continually monitors the health of each input channel. If the module detects that an input signal is outside the configured measurement range (below minimum or above maximum valid values), it will automatically generate an Underrange or Overrange alarm and update the module status accordingly.
The 1797-IRT8 Allen-Bradley FLEX Ex RTD/Thermocouple/mV Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Allen-Bradley 1797-IRT8 FLEX Ex RTD/Thermocouple/mV Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Allen-Bradley 1797-IRT8 FLEX Ex RTD/Thermocouple/mV Module Specs
General
- Manufacturer Allen-Bradley
- Model 1797-IRT8
- Condition New Original ready stock
- Product Family 1797-TB3 ,1797-TB3S ,1797-OE8
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Hazardous Area Temperature Monitoring: Specifically designed for locations where explosive gases, vapors, or dust may be present (ATEX Zone 1/2).
- Precision Process Sensing: Used with a variety of high-accuracy sensors, including thermocouples (Types J, K, T, etc.), RTDs (Pt100, Pt200), and general millivolt sources.
- Refining & Chemical Processing: Ideal for monitoring vessel temperatures or chemical reactions where intrinsic safety is mandatory.
- Marine & Offshore Applications: Often used in harsh industrial settings, supported by certifications like marine-GL.
- Network Integration: Primary connectivity is via ControlNet Ex networks for high-speed, scheduled data transfer between the module and a programmable controller.
- Bus Interface: The module connects to the system via the Flexbus using an intrinsically safe terminal base like the 1797-TB3 or 1797-TB3S.
- I/O Transfer: Uses Block Transfer Read (BTR) and Block Transfer Write (BTW) instructions within ladder logic to exchange configuration and measurement data with the PLC.
- Wiring Support: Supports 2-, 3-, or 4-wire RTD configurations and uses 12 AWG stranded cables for field connections.
- High-Speed Sampling: Features a fast 8-millisecond settling time and 16-bit resolution for precise process control.
- Configurable Filtering: Offers selectable digital firmware filters (ranging from 600 Hz to 0.2 Hz) to balance noise reduction against response speed.
- Built-in Diagnostics: Provides status monitoring for critical faults, including: Open Wire Detection: Identifies broken sensor connections.
- Overrange/Underrange: Monitors if signals exceed the 0–485 Ω or -40 to +100 mV limits.
- CJC Faults: Detects issues with Cold Junction Compensation, essential for accurate thermocouple readings.
- Visual Indicators: Equipped with 8 red fault LEDs for individual channel monitoring and 1 green module power LED.