See a real on-site verification case >>
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power can review the RS-232 (DF1) link, DC supply and shared application-transfer port before quotation.

2711-K3A17L1

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2711-K3A17L1 is a PanelView Standard 300 monochrome keypad terminal with RS-232 (DF1) communication and 24 V DC power.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 2711-K3A17L1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2711-K3A17L1

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2711-K3A17L1
  • Product Family:
    PanelView
  • Product Type:
    Standard Operator Terminal
  • Stock:
    1
  • Display Size:
    3 inches
  • Display Type:
    Monochrome transflective LCD with LED backlight
  • Display Area (WxH):
    73 x 42 mm (2.87 x 1.67 in)
  • Resolution:
    128 x 64 pixels
  • Backlight Life:
    100,000 hours (non-replaceable)
  • Input Type:
    Keypad (stainless steel domed membrane)
  • Function Keys:
    8 (F1...F8)
  • Keypad Life:
    2 million actuations
  • Communication Port:
    1 x RS-232 (DF1 protocol) — no printer port
  • Application Memory (Runtime):
    170 KB
  • Nonvolatile Memory:
    240 KB
  • Input Voltage:
    18-32V DC (24V DC nom)
  • Power Consumption:
    10 VA (0.42 A at 24V DC)
  • Heat Dissipation:
    6 W (13 BTU/hr)
  • Operating Temperature:
    0…55 °C (32…131 °F)
  • Storage Temperature:
    -25…70 °C (-13…158 °F)
  • Relative Humidity:
    5…95% non-condensing 0…30 °C
  • Weight:
    0.56 kg
  • Estimated shipping dimensions:
    14x13.5x19.5cm
  • Tariff Code:
    8537101990
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Model Identity System Interface Service Boundaries Applications

Features:

  • PanelView 300 monochrome display
  • Keypad-only operator interface
  • RS-232 (DF1) communication with 24 V DC power
2711-K3A17L1 is a compact PanelView 300 with eight function keys, cursor keys and numeric-entry controls. Its monochrome display presents the application text, controls and graphics assigned to those keys.

The catalog code identifies RS-232 (DF1) controller communication, while the L1 suffix identifies 24 V DC input power. This combination separates the terminal from DeviceNet and DH-485 PanelView 300 variants.

This model has no separate RS-232 printer port. The communication port is also used for application upload and download, so service work must restore both the file-transfer path and the installed DF1 settings.

For Allen-Bradley 2711-K3A17L1 PanelView enquiries, Apter Power can help review the RS-232 (DF1) connection, 24 V DC supply and stored terminal application.
Allen-Bradley 2711-K3A17L1 PanelView 300 Standard Operator Terminal Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • 2711-K3A17L1: PanelView 300 monochrome operator terminal
  • Keypad-only operator input with eight function keys
  • Catalog communication option: RS-232 (DF1)
  • L1 suffix: 24 V DC input power
  • 2711-K3A17L1: The RS-232 port carries the DF1 controller connection
  • The same communication port supports application upload and download
  • No separate RS-232 printer port is provided on this catalog
  • Runtime service must restore both DF1 settings and the application-transfer path
  • 2711-K3A17L1: Do not use the terminal for emergency stops or other safety-critical controls
  • Keep safety-critical personnel and equipment functions on separate hardwired devices
  • Do not substitute a DeviceNet or DH-485 PanelView 300 for this RS-232 (DF1) catalog
  • Match the L1 24 V DC supply requirement before installing a replacement
  • 2711-K3A17L1: Local monochrome operator screens on an installed RS-232 (DF1) system
  • Application-defined commands through eight physical function keys
  • Cursor-based list navigation and numeric or ASCII value entry
  • Stored-application maintenance through the shared communication and transfer port
Description
2711-K3A17L1 is a 3-inch monochrome PanelView 300 with keypad-only operator input, RS-232 (DF1) controller communication and the L1 24 V DC power configuration.

2711-K3A17L1 has no separate RS-232 printer port; the communication port is also used to upload and download application files. That shared path makes port availability and restored DF1 settings central to service planning.

2711-K3A17L1 keeps eight function keys and cursor-based data entry in a compact panel format. Retaining the key assignments with the application backup helps maintenance restore the original operator workflow without assuming a touch interface exists.
Revisions

Revision Part #

Also known as

2711-K3A17L1 Ser A
2711-K3A17L1/A, Series A, Rev A
2711-K3A17L1 Ser B
2711-K3A17L1/B, Series B, Rev B
2711-K3A17L1X
2711-K3A17L1/X, Series X, Rev X
Alternative Names
2711-K3A17LI 2711-K3AI7L 2711K3A17L1 2711K3A17LI 2711K3AI7L1 271I-K3A17L1 271IK3A17L1 27I1-K3A17L1
Technical notes
2711-K3A17L1 is a legacy PanelView Standard terminal. Verify the RS-232 (DF1) interface, 24 V DC supply, installed application, panel dimensions and keypad requirements before service. Do not approve a substitute without documented communication, mechanical and application validation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which port should a technician use to upload an application to 2711-K3A17L1?
Use the RS-232 (DF1) communication port. This catalog does not have a separate printer port, so the same connection handles controller communication and application transfer.
Can a DeviceNet PanelView 300 replace 2711-K3A17L1 without network changes?
No. The current catalog uses RS-232 (DF1); a DeviceNet unit changes the controller interface and is not a like-for-like communications spare.
Can a serial printer remain permanently connected to 2711-K3A17L1?
There is no dedicated printer port on this model. The single communication port is required for DF1 operation and application transfer, so do not plan it as an independent printer connection.
What power source is required when staging 2711-K3A17L1?
Stage the 24 V DC installation identified by the L1 suffix. An AC-powered terminal is a different configuration and should not be wired as a direct replacement.
Can a touch-oriented application be operated unchanged on 2711-K3A17L1?
No. This terminal is keypad only; every required command and data-entry path must be reachable through its physical function, cursor and numeric keys.
After transferring an application, 2711-K3A17L1 no longer exchanges controller data; what should maintenance restore first?
Restore the DF1 cable path and the serial settings used by the installed controller. The shared port may transfer a file successfully yet still need the correct runtime configuration.
How should 2711-K3A17L1 be distinguished from the similar 2711-K3A10L1 during procurement?
Use the communications code: this unit is RS-232 (DF1), while 2711-K3A10L1 is the DeviceNet configuration. Matching only size and DC power is insufficient.