B&R X20BM11 is a 24 VDC-keyed X20 bus module that provides the base for 24 VDC I/O modules and passes the internal I/O supply through for the X20 System.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for X20BM11
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for X20BM11

  • Manufacturer:
    B&R
  • Part Number:
    X20BM11
  • Product Family:
    B&R X20 System
  • Product Type:
    24 VDC Bus Module
  • Stock:
    1
  • Bus-module keying:
    24 VDC
  • I/O supply nominal voltage:
    24 VDC
  • Permissible contact load:
    10 A
  • Bus power consumption:
    0.13 W
  • Module function:
    Base for 24 VDC X20 I/O modules
  • Module pitch:
    12.5 mm +0.2 mm
  • Mounting orientation:
    Horizontal or vertical
  • Degree of protection:
    IP20
  • Operating temperature:
    -25 to 60 °C horizontal; -25 to 50 °C vertical
  • Storage temperature:
    -40 to 85 °C
  • Operating humidity:
    5 to 95%, non-condensing
  • Dimensions:
    1.42 × 5.2 × 10.96 cm
  • Tariff Code:
    8538900000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Potential Group Compatibility Environment Application
  • Provides the base for standard-width 24 VDC X20 I/O modules
  • Maintains continuity of the internal I/O power supply
  • Uses 24 VDC keying and supports a permissible contact load of 10 amperes

X20BM11 is a B&R 24 vdc bus module designed for the X20 System.

The module supports the electronic module and terminal block and continues the 24 VDC I/O supply to adjacent slices in the same X20 potential group.

Before installation or replacement, verify the complete material number, 24 VDC keying, electronic-module compatibility, terminal-block compatibility, potential-group boundaries, 10 A contact-load limit, neighboring bus-module type, and station layout.

Availability, condition, price, and shipping time for X20BM11 are confirmed during quotation.

B&R X20BM11 24 VDC Bus Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • The internal I/O power supply remains connected through the bus module
  • The module is used inside an existing 24 VDC potential group
  • A power-supply bus module is required when the supply must be interrupted to form a new group
  • The mechanical coding is intended for 24 VDC X20 I/O modules
  • The electronic module and terminal block must use the matching 24 VDC keying
  • Standard-width X20 slices use the documented 12.5 millimeter pitch
  • Horizontal and vertical mounting orientations are supported
  • Operation is specified for non-condensing relative humidity
  • Installation above 2000 meters requires the documented ambient-temperature reduction
  • Building standard 24 VDC X20 I/O slices
  • Continuing the internal I/O supply within an X20 potential group
  • Providing the bus base for compatible 24 VDC electronic and terminal modules
Description
X20BM11 is a B&R 24 vdc bus module for the X20 System automation platform.

It forms the mechanical and electrical base of a standard-width 24 VDC X20 I/O slice while maintaining continuity of the internal I/O power supply across the potential group.

Before installation or replacement, confirm the complete material number, 24 VDC keying, electronic-module compatibility, terminal-block compatibility, potential-group boundaries, 10 A contact-load limit, neighboring bus-module type, and station layout.
Alternative Names
X20BM11 X20 BM 11 X20-BM11 B&R X20BM11 BR X20BM11 B&R X20 BM11
Technical notes
X20BM11 passes the internal 24 VDC I/O supply through and does not start a new potential group; verify module keying, 10 A contact load, neighboring bus modules, terminal block, and complete X20 station layout before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does B&R X20BM11 create a new potential group?
No. Its internal I/O power supply is connected through. Use the officially specified power-supply bus-module arrangement when a new potential group must be created.
How can B&R X20BM11 be distinguished from X20BM01?
X20BM11 continues the internal I/O supply, whereas X20BM01 interrupts the supply to the left and is used as the base for power-supply modules and new potential groups.
Can B&R X20BM11 be used with 240 VAC-keyed X20 modules?
No. X20BM11 is 24 VDC keyed; use the bus module officially specified for the complete electronic-module and terminal-block combination.
What should be checked if modules to the right of B&R X20BM11 lose I/O power?
Inspect the upstream supply module, potential-group boundary, bus contacts, module seating, contact load, neighboring bus modules, and the station power calculation.
Is B&R X20BM11 an electronic I/O module?
No. It is the bus base for a compatible electronic module and terminal block and provides mechanical support plus bus and I/O-supply continuity.
What limits apply when extending a station through B&R X20BM11?
Respect the documented 10 A contact load and complete X20 power budget; do not judge capacity solely from the number of installed slices.
What should be recorded before replacing B&R X20BM11?
Record its exact position, adjacent module catalog numbers, keying, potential-group boundary, upstream supply source, terminal block, and station power calculation.