- External access permits probe adjustment or replacement without dismantling the machine case
- Type 4X and IP66 housing protects the installed probe connection in industrial environments
- API 670 housing configuration supports externally mounted proximity measurements on rotating machinery
31000-16-05-00-079-03-02 provides a protected and externally accessible mounting point for a proximity probe installed through the machine casing.
The housing allows maintenance personnel to inspect, gap, or replace the probe from outside the machine while helping protect the adjustment mechanism and cable connection from the surrounding environment.
This configured assembly includes the installed probe and its short lead. The matching extension cable, Proximitor Sensor, monitoring channel, and any required intrinsic-safety hardware remain separate parts of the measurement system.
Availability, condition, price, and shipping time for 31000-16-05-00-079-03-02 are confirmed during quotation.
Bently Nevada 31000-16-05-00-079-03-02 Proximity Probe Housing Assembly Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The housing permits probe-gap adjustment from outside the machine
- The probe can be replaced without disassembling the machine casing
- Conduit and cable routing must preserve access to the housing cover
- Conductive glass-reinforced PPS provides corrosion resistance
- The assembled housing is rated Type 4X and IP66
- The enclosure is not an explosion-proof housing
- The 7.9 in penetration is below the 12 in sleeve-support threshold when no standoff is used
- The 0.5 m probe lead permits up to 15.5 in combined standoff and penetration
- Probe-label visibility outside the sleeve is not maintained at the 7.9 in penetration
- Radial shaft-vibration measurement through a machine case attached to the bearing structure
- Keyphasor or speed-reference measurement requiring external probe access
- Protected probe installation where gap adjustment or probe replacement must be performed without dismantling the machine