Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

82365-01

/ 4.9
1001 reviews | Need a Specific Revision?
The Bently Nevada 82365-01 is a dual epoxy-sealed relay designed to convert alarm signals from 3300 Series monitors into physical contact outputs. It provides reliable triggering for shutdown circuits or alarm indicators in industrial temperature monitoring systems.
Get a quick price for 82365-01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 82365-01

  • Manufacturer:
    Bently Nevada
  • Part Number:
    82365-01
  • Product Family:
    3300 System
  • Contact type:
    2 independent single-pole double-throw (SPDT) relays.
  • Sealing method:
    Epoxy-sealed
  • Contact capacity (resistive load):
    5A @ 120 VAC (50/60 Hz) / 5A @ 24 VDC
  • Operating Temperature:
    0°C to +65°C (+32°F to +150°F).
  • Storage Temperature:
    -40°C to +85°C (-40°F to +185°F).
  • Relative Humidity:
    To 95%, non-condensing.
  • Weight:
    0.34 kg
  • Estimated shipping dimensions:
    5x9.8x22.8cm
  • Tariff Code:
    6602000090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Efficiency Certifications Applications

Features:

  • Dual Epoxy-Sealed SPDT Relays Provide Reliable Alarm Signal Conversion.
  • Capable Of Handling 5 A Resistive Loads At 120 VAC Or 24 VDC For Industrial Devices.
  • Designed For Rear-Rack Installation With High Humidity And Temperature Tolerance.
The Bently Nevada 82365-01 relay enhances the 3300 Series monitoring system by converting electronic alarm signals into actionable physical outputs. This ensures that machinery receives timely warnings or shutdowns to prevent damage.

Its epoxy-sealed construction protects against moisture and dust, guaranteeing consistent performance in industrial environments. The dual independent relays allow separate outputs for alarms or shutdown circuits, providing design flexibility.

By integrating seamlessly with the 3300/30 and 3300/35 monitors, the module supports predictive maintenance strategies. Operators benefit from reliable, multi-channel alarm management, reduced downtime, and improved overall safety.

The 82365-01 Bently Nevada Dual Epoxy Relays may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 82365-01 Dual Epoxy Relays Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 82365-01 Dual Epoxy Relays Specs

General

  • Manufacturer GE / Bently Nevada
  • Model 82365-01
  • Condition New Original ready stock
  • Product Family 84141-01,84140-01,84137-01
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • High-Reliability Sealing: Epoxy resin encapsulation effectively isolates contacts from moisture, corrosive gases, and industrial dust, ensuring no oxidation in harsh environments.
  • Low-Delay Response: Extremely short relay operating time (typically in the millisecond range) ensures rapid triggering of downstream protection circuits when monitored values ​​exceed limits.
  • Contact Durability: Designed to support tens of thousands of electrical operation cycles, exhibiting extremely low contact resistance at rated current, reducing heat-related losses.
  • Flexible Configuration: Supports normally open (NO) or normally closed (NC) logic and can be configured for "normally energized" operation to achieve fail-safe functionality.
  • CSA/NRTL/C: Compliant with North American electrical safety standards, allowing operation in Class 1, Division 2 hazardous areas.
  • CE Certification: Compliant with EU Low Voltage Directive (LVD) and Electromagnetic Compatibility (EMC) specifications.
  • IEEE/ANSI Surge Testing: Complies with relevant surge and pulse interference standards, ensuring the stability of the control loop.
  • Sealing Rating: Due to epoxy encapsulation, its vibration resistance and corrosion resistance meet MIL-SPEC or related industrial-grade sealing requirements.
  • Emergency Stop Interlock (ESD): When the 3300 monitor detects machine vibration or temperature reaching the "Danger" level, this module triggers the stop loop.
  • Remote Alarm Notification: Transmits alarm signals to the digital input terminals of the central control room (DCS/PLC) or directly drives on-site audible and visual alarms.
  • Auxiliary Equipment Switching: Automatically starts the backup cooling pump or fan using relay contacts when a main pump failure or excessive temperature rise is detected.
  • Logic Interlock: Works with other control systems to achieve permissive start logic verification before starting large rotating machinery.
Description
The 82365-01 Dual Epoxy Relay is engineered for use with the Bently Nevada 3300 Series monitoring system, including the 3300/30 six-channel TC monitor and the 3300/35 RTD monitor. Mounted at the rear of the monitoring rack, it receives alarm signals from the monitor and activates independent SPDT contacts to control external devices.

Each relay is epoxy-sealed, ensuring robust protection against dust, moisture, and other environmental factors. The relays handle resistive loads up to 5 A at 120 VAC (50/60 Hz) or 5 A at 24 VDC, providing reliable actuation of shutdown circuits, alarm lights, or other control mechanisms.

Designed for industrial conditions, the 82365-01 operates within 0°C to +65°C and can be stored safely between -40°C and +85°C. With a relative humidity tolerance of up to 95% non-condensing, the module maintains dependable performance in environments where moisture or humidity may vary.

By integrating seamlessly with the 3300/30 and 3300/35 monitors, the module ensures timely response to temperature excursions. This enhances machinery protection, reduces risk of failure, and supports preventive maintenance strategies.

The dual-channel configuration allows independent control of two separate alarm outputs, offering flexibility in system design. Its installation at the rear rack location optimizes wiring and simplifies access during maintenance or system upgrades.
Alternative Names
82367-01 82368-01 81544-01 82365-02 81545-01
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many contacts does each relay provide?
Each module contains two independent SPDT relays.
Can these contacts be used for different control purposes simultaneously?
Yes, one relay can activate a shutdown circuit while the other triggers an alarm light, offering flexible system integration.
Why is epoxy sealing used for this relay?
Epoxy sealing protects the relay from dust, moisture, and other environmental contaminants.
How does the 82365-01 relay interact with the 3300/30 or 3300/35 monitors?
It receives alarm signals from the monitor and actuates its SPDT contacts to trigger external devices.