Features:
- The M10 x 1 stainless-steel case carries an unarmored 8 mm probe tip.
- A 1.0 m standard cable terminates at a protected miniature ClickLoc coaxial connector.
- The configured probe forms the sensing end of a 3300 XL proportional gap-voltage measurement chain.
The 00 unthreaded-length code and 08 overall-case code establish a metric body with no plain shank and an 80 mm case.
Probe resistance for the 1.0 m lead is specified at 7.59 ±0.50 ohms from the center conductor to the outer conductor.
The option 01 connection combines standard probe cable with a ClickLoc connector protector rather than FluidLoc or armor.
The Bently Nevada 330103-00-08-10-01-00 3300 XL 8 mm Proximity Probe may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330103-00-08-10-01-00 3300 XL 8 mm Proximity Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Metric Case and Sensing End
- Metric thread: The 330103 body uses an M10 x 1 mounting thread without protective armor.
- Case geometry: Option 08 establishes an 80 mm overall case around the 8 mm tip.
- Unthreaded section: Option 00 specifies a 0 mm plain length ahead of the threaded case.
- Pressure seal: A Viton O-ring separates pressure at the probe tip from the case side.
One-Metre Standard Lead
- Lead selection: Code 10 sets the total probe cable length to 1.0 m.
- Cable construction: Option 01 uses the standard 75-ohm coaxial probe cable.
- Connector lock: The miniature coaxial ClickLoc joint is tightened finger-tight.
- Protector role: A connector protector covers the cable joint after the probe and extension lead are joined.
From Target Gap to Monitor Voltage
- Target interaction: The probe tip senses a conductive surface without physical contact.
- Signal transfer: The 1.0 m lead carries the probe response to the Proximitor Sensor electronics.
- Voltage conversion: The complete 1 m system scales gap movement at 7.87 V/mm within its linear range.
- Monitor connection: Shielded field wiring continues from the Proximitor Sensor to the monitoring channel.
Thread, Gap, and Temperature Checks
- Thread engagement: The M10 x 1 case should not engage more than 15 mm of internal thread.
- Radial gap: The documented nominal setup is approximately 1.27 mm from the target at -9 V DC.
- Temperature: Standard probe operation and storage extend from -52 to +177 deg C.
- Seal exposure: Temperatures below -34 deg C can shorten pressure-seal life even though the electrical temperature range extends lower.