The Bently Nevada 109548-01 P1407030-00100 is a high-performance 3300XL NSv Proximity Probe designed for non-contact vibration and displacement monitoring of critical rotating machinery.
Discover how Apter Power helps customers source hard-to-find automation parts,overcome delivery challenges and keep production moving.VIEW OUR SUCCESS STORIES >>
Technical specifications for 109548-01 P1407030-00100
Manufacturer:
Bently Nevada
Part Number:
109548-01 P1407030-00100
Product Family:
NSV Probe
Measuring Range:
0 to 2 mm (0 to 80 mils)
Linear Range:
0.25 mm to 1.5 mm (10 to 60 mils)
Sensitivity:
7.87 mV/mil (3.937 mV/μm) per volt
Frequency Response:
0 to 10 kHz
Power Supply (DC Voltage):
-22 V to -26 V
Weight:
0.14 kg
Estimated shipping dimensions:
1.4x1.1x111cm
Tariff Code:
8537101190
Country of origin:
USA
Place of shipment:
Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.
Description
The Bently Nevada 109548-01 P1407030-00100 is an integral component of the 3300XL NSv monitoring series, specifically engineered for precise, non-contact measurement of vibration and displacement in high-speed rotating machinery. As an eddy-current proximity probe, the 109548-01 P1407030-00100 operates on the principle of electromagnetic induction, where a high-frequency alternating current in the probe coil generates a magnetic field.
When this field interacts with a conductive target (typically the machine shaft), eddy currents are induced, changing the coil's impedance.The performance of the 109548-01 P1407030-00100 is defined by its exceptional technical specifications. It features a broad measuring range of 0 to 2 mm (80 mils), with a specified linear range of 0.25 mm to 1.5 mm (10 to 60 mils) for high-precision measurements.
Its sensitivity is rated at 7.87 mV/mil (3.937 mV/μm) per volt of excitation. To withstand harsh industrial environments, the 109548-01 P1407030-00100 probe body is rated for an operating temperature range of -35°C to +177°C, while its PTFE-sheathed cable can endure temperatures from -51°C to +177°C.
Installation of the 109548-01 P1407030-00100 is designed for reliability. The probe, with a standard length of 3 meters (approx. 9.8 feet) and a diameter of 5 mm, is typically mounted near equipment bearings or other rotating components where vibration is most significant.
The mounting hole must match the 5 mm diameter to ensure stability. A critical installation parameter is the gap setting; the distance between the probe tip and the target must be adjusted to fall within the probe's 0.25 mm to 1.5 mm linear range to ensure optimal sensitivity and measurement accuracy.
We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
Trust Guaranteed
Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
Expertise
Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.
FAQS
The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What are the key operating ranges for the Bently Nevada 109548-01 P1407030-00100 proximity probe, and why is the linear range critical?
The Bently Nevada 109548-01 P1407030-00100 has a full measuring range of 0 to 2 mm (80 mils). Its specified linear range of 0.25 mm to 1.5 mm (10 to 60 mils) is the gap distance over which the probe's output voltage is guaranteed to have a precise, linear relationship with the actual physical displacement. Operating the 109548-01 P1407030-00100 within this linear range is critical to ensure high-precision measurement and accurate data for machinery protection and condition monitoring algorithms.
What environmental conditions can the 109548-01 P1407030-00100 withstand, and what material ensures cable durability?
The 109548-01 P1407030-00100 is built for harsh environments. The probe body operates from -35°C to +177°C, and its cable from -51°C to +177°C. The cable features a Polytetrafluoroethylene (PTFE) jacket, which provides exceptional resistance to chemicals, oils, and abrasion. This, combined with the wide temperature rating, ensures the long-term reliability of the 109548-01 P1407030-00100 in demanding applications like power generation and oil & gas.
How is the 109548-01 P1407030-00100 powered, and what is its signal frequency response capability?
The 109548-01 P1407030-00100 proximity probe requires a -22 V to -26 V DC power supply from its compatible 3300 NSv series driver. Its electrical output has a frequency response of 0 to 10 kHz. This broad bandwidth allows the 109548-01 P1407030-00100 to accurately measure both slow-changing relative position (e.g., shaft float) and high-frequency vibration components, making it suitable for comprehensive machinery diagnostics.
What is a crucial mechanical consideration during the installation of the 109548-01 P1407030-00100?
A vital mechanical installation step for the 109548-01 P1407030-00100 is setting the correct air gap. The distance between the probe's tip and the target surface must be established within its linear range of 0.25 mm to 1.5 mm (10 to 60 mils) during initial commissioning. An incorrect gap—either too large or too small—will place the 109548-01 P1407030-00100 outside its linear operating zone, leading to inaccurate readings, reduced sensitivity, and potential false alarms in the monitoring system.