Features:
- 7200 Series 5 mm probe: The compact sensing element supports non-contact measurement in restricted machine locations.
- Legacy mounting geometry: The 1/4-28 UNF body and 2.8 inch case fit the documented 7200 bracket.
- One-metre unarmored lead: The miniature coaxial termination requires a protected route to the matching extension cable.
Mounting decision: Confirm thread, case reach and target clearance before disturbing the original bracket setting.
System decision: Match the probe with the documented 7200 extension-cable and 5 mm Proximitor electrical length.
Signal decision: Set the static gap and verify monitor scale before using the channel for position or vibration.
Apter Power supports Bently Nevada 21500-00-28-10-02 with technical documentation, quotations and legacy 7200 system review.
Bently Nevada 21500-00-28-10-02 7200 Series 5 mm Proximity Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Thread: The 1/4-28 UNF body fits compact legacy adjustment brackets.
- Case length: The 2.8 inch case defines the available insertion reach.
- Tip section: Zero unthreaded length places the mounting thread close to the sensing end.
- Cable construction: The 1.0 m lead has no armor and should be restrained away from abrasion and heat.
- Probe lead: The 1.0 m unarmored lead forms the first section of the calibrated electrical path.
- Extension cable: Use the compatible 7200 cable to complete the required system length.
- 5 mm electronics: Connect the chain to the Proximitor unit specified for the 7200 5 mm probe family.
- Coaxial connector: Keep the miniature male interface clean, dry and fully engaged.
- Static position: Adjust the probe until conditioned output is centered within its useful linear range.
- Scale check: Review target alloy, total electrical length and 5 mm electronics before changing calibration.
- Unstable signal: Inspect mount rigidity, connector cleanliness, cable strain and grounding.
- Mechanical runout: Compare slow-roll waveform with the target surface before attributing motion to the shaft.
- Compact bearing points: Measure shaft-relative movement where installation space is limited.
- Thrust position: Track axial displacement with a suitable small-target arrangement.
- Legacy 5 mm channels: Maintain an installed 7200 measurement architecture without changing probe geometry.
- Machine diagnostics: Provide proximity data for runout assessment, trending and alarm functions.