The Model 7200 proximity sensor system (21504-00-12-10-02) is a precision proximity sensing solution designed specifically for industrial measurement applications.
Get a quick price for 21504-00-12-10-02
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 21504-00-12-10-02

  • Manufacturer:
    Bently Nevada
  • Part Number:
    21504-00-12-10-02
  • Product Family:
    7200 Proximity Transducer Systems
  • Diameter:
    8 mm
  • Configuration type:
    Standard
  • Configuration threads:
    3/8-24 thread
  • Lead armor:
    no
  • Unthreaded Length:
    0.0 inches
  • Overall Case Length:
    1.2 inches
  • Total Length:
    1.0 metre (39 inches).
  • Connector Option:
    With miniature male coaxial connector.
  • Weight:
    0.12 kg
  • Estimated shipping dimensions:
    20.4cm x 22.2cm x 3.7cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.
Description
21504-00-12-10-02 is a configured model within the 7200 Proximity Transducer System, designed for non-contact measurement of shaft vibration, displacement, and position in rotating machinery. The 21504-00-12-10-02 probe is engineered to provide stable and accurate eddy current sensing performance, making it suitable for continuous condition monitoring and machinery protection systems. The 21504-00-12-10-02 follows a standard configuration design, ensuring compatibility with typical industrial monitoring applications and installation requirements.

In physical design, 21504-00-12-10-02 features an 8 mm probe diameter, which is commonly used in proximity measurement applications requiring compact installation and reliable measurement resolution. The 21504-00-12-10-02 is configured with 3/8-24 mounting threads, allowing secure installation into machine casings or mounting brackets. This thread specification ensures stable probe positioning and supports consistent measurement accuracy during equipment operation.

Regarding structural configuration, 21504-00-12-10-02 is manufactured with no lead armor, providing flexibility and ease of routing during installation. The probe is designed with an unthreaded length of 0.0 inches, allowing direct threaded mounting without an extended unthreaded section. The overall case length of 1.2 inches supports compact installation in applications where mounting space is limited, while maintaining structural durability and probe integrity.

In cable and dimensional specifications, 21504-00-12-10-02 includes a total cable length of 1.0 meter (39 inches). The length tolerance for 21504-00-12-10-02 is specified as +0.25 meter and -0.10 meter (+10 inches and -4 inches), ensuring installation flexibility while maintaining system calibration performance. This cable configuration supports proper signal transmission between the probe and associated monitoring or driver systems.

For connectivity, 21504-00-12-10-02 is equipped with a miniature male coaxial connector, allowing secure and reliable electrical connection with compatible extension cables and monitoring equipment. The connector design of 21504-00-12-10-02 supports stable signal transmission and helps maintain measurement accuracy in industrial environments.

Overall, 21504-00-12-10-02 integrates an 8 mm probe diameter, standard configuration design, 3/8-24 mounting threads, compact case structure, defined cable length tolerance, and miniature coaxial connector interface, enabling 21504-00-12-10-02 to deliver dependable proximity measurement performance in rotating machinery monitoring systems.
Alternative Names
21504 00 12 10 02 21504-00-12-10-00 21504-00-12-05-02 21504-00-12-50-02 21504-00-12-90-02
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the 21504-00-12-10-02 relative humidity limit?
The system supports a maximum relative humidity of 95 %, under non-condensing conditions.
What are the operating temperature limits?
The operating temperature range is –51 °C to +100 °C (–60 °F to +212 °F) for the Proximitor, and –34 °C to +177 °C (–30 °F to +350 °F) for the probe and cable assembly.
How does temperature affect the scale factor?
The scale factor typically changes by –3 % at +65 °C (+150 °F) when measured with a 50 mil (1.27 mm) probe gap.