Features:
- Loop-powered two-wire thrust transmitter with a ±0.6 mm (±25 mil) full-scale range.
- Option 01 specifies 35 mm DIN-rail clips; bulkhead screws are associated with option 02.
- During a Not OK condition, the output decreases to below 3.6 mA within 100 microseconds.
The 991-06-XX-01-05 MOD:164113-01 converts axial displacement from a compatible 3300 NSv proximity transducer system into a 4–20 mA proportional current signal. PROX OUT and COM connections are provided for diagnostic access.
The XX segment denotes a modified system-length configuration. The exact probe and extension-cable combination for MOD 164113-01 must be verified from MOD-specific documentation or the unit nameplate rather than inferred from standard 5 m or 7 m options.
Current OEM lifecycle classification is not stated in the available Bently Nevada documentation. Availability is confirmed during quotation.
Bently Nevada 991-06-XX-01-05 MOD:164113-01 Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bently Nevada 991-06-XX-01-05 MOD:164113-01 Thrust Transmitter Specs
General
- Manufacturer Bently Nevada
- Model 991-06-XX-01-05 MOD:164113-01
- Condition New Original ready stock
- Product Family 991 Thrust Transmitter, 3300 NSv Proximity Transducer System
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Option 01 specifies 35 mm DIN-rail clips for this transmitter configuration.
- Bulkhead mounting screws correspond to option 02 and should not be assumed for the 01 configuration.
- Confirm panel space, wiring access, and the full option code before replacing the installed transmitter.
- Provides a 4–20 mA proportional current output for the measured thrust position.
- PROX OUT and COM connections provide access to dynamic vibration and gap-voltage signals for diagnostics.
- After a Not OK condition is detected, the output decreases to below 3.6 mA within 100 microseconds.
- Option 06 specifies the ±0.6 mm (±25 mil) full-scale measurement range.
- XX denotes a modified system-length configuration; verify MOD 164113-01 from MOD-specific documentation or the nameplate.
- Compare the complete model, MOD number, mounting option, approvals, probe, and extension-cable configuration before ordering.