Features:
- Four-channel simultaneous vibration data acquisition supporting accelerometer, velocity, displacement, and voltage sensors.
- High spectral resolution up to 12,800 lines with a maximum frequency range (Fmax) of up to 80 kHz.
- Intrinsically safe design rated for ATEX/IECEx Zone 0/20 and CSA Class 1 / Div 1 hazardous environments.
This item represents the standard SCOUT240-IS intrinsically safe portable data acquisition module (Hardware ID: 109M2380) equipped with a custom 7.4 V rechargeable battery pack, dual LEMO sensor inputs, and a tachometer interface.
Designed for machinery condition monitoring in hazardous locations, the unit wirelessly pairs via Bluetooth to an industrial handheld device running the S1 Collector app and syncs seamlessly with System 1 software for route execution, spectrum analysis, and advanced diagnostics.
Ensure sensor connections use the supplied CH2-4 breakout cable for 4-channel measurements, use safety breakaway neck straps during operation, and complete battery charging within non-hazardous ambient temperatures (0°C to 25°C).
The SCOUT240-IS Portable Data Collector is available for shipment with original factory-level specifications guaranteed by the manufacturer (OEM).
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- On-route and off-route vibration data collection and machine condition monitoring in industrial plant environments.
- Two-plane dynamic rotor balancing and field vibration diagnostics on rotating machinery.
- Modal impact testing and structural resonance analysis using optional instrumented hammers and cross-channel FRF export.
- Operating temperature range from -20°C to 60°C (-4°F to 140°F), with a maximum of 50°C (122°F) in Ex hazardous areas.
- Recommended ambient temperature range for battery charging is strictly between 0°C and 25°C (32°F to 77°F).
- Short-term storage tolerance up to 95% relative humidity and long-term storage capability at up to 35°C (95°F) with 85% RH.
- Equipped with a custom 7.4 V, 3920 mAh Lithium-Ion battery pack offering typical 10-hour continuous on-route operating time.
- Features high-speed 24-bit analog-to-digital conversion with Harmonic Distortion levels typical below -70 dB.
- Internal automatic charge control fully recharges the battery pack in approximately 3 hours at a 2 A nominal rate.
- Configurable sensor excitation delivering 0 mA or 2.2 mA at 24 V max to power IEPE/ICP-type accelerometers.
- User-selectable spectral window shapes including Hanning and Rectangular with overlap options up to 87.5%.
- Supports flexible averaging methods including Linear, Exponential, and Peak Hold with up to 128 average selections.