Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports quotations, documentation, procurement and module-terminal matching for this legacy field terminal.

8601-FT-NI

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson PAC8000 8601-FT-NI non-incendive field terminal for compatible I/O modules in documented Zone 2 or Class I Division 2 installations.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 8601-FT-NI
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 8601-FT-NI

  • Manufacturer:
    Emerson
  • Part Number:
    8601-FT-NI
  • Product Family:
    PAC Systems
  • Product Type:
    Non-Incendive Field Terminal
  • Stock:
    1
  • Manufacturer:
    Emerson
  • Product family:
    PAC8000
  • Exact model:
    8601-FT-NI
  • Product type:
    Non-incendive field terminal
  • Channel protection:
    Unfused
  • Terminal rating:
    250 Vac maximum
  • Current rating:
    3 A maximum per channel
  • Conductor range:
    0.14–2.5 mm²
  • Installation context:
    Zone 2 / Class I Division 2 per control drawing
  • Weight:
    0.08 kg
  • Estimated shipping dimensions:
    8.8 × 4.1 × 4.2 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Wiring Interface Module Pairing Area Classification Product Applications

Features:

  • Non-incendive construction: Provides a documented field termination option for compatible PAC8000 I/O modules.
  • Unfused channels: Maintains direct field connections without individual terminal fuses.
  • Removable interface: Separates field wiring from the plug-in I/O module for structured maintenance.
Termination role: The assembly connects cabinet field wiring to the electrical channels of a supported module.

Selection identity: NI identifies the non-incendive variant and should remain with the complete model.

Installation boundary: Terminal ratings and area use are governed by the paired module and approved control drawing.

Apter Power supports sourcing of the Emerson 8601-FT-NI Non-Incendive Field Terminal with quotations, technical documentation and configuration review.
Emerson 8601-FT-NI Non-Incendive Field Terminal Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Wire preparation: Conductor and termination methods should follow the terminal limits so field connections remain secure.
  • Unfused path: Protection required by the field circuit must be provided elsewhere in the design.
  • Circuit loading: Connected devices should remain within the electrical limits of both the terminal and its paired module.
  • Service access: Removable termination lets field wiring stay organized while module-side maintenance is performed.
  • Key compatibility: The terminal key must agree with the selected PAC8000 I/O module.
  • Channel mapping: Field terminals follow the module-specific channel assignments and circuit type.
  • Protection choice: The unfused design should be selected only where the circuit plan provides the required protection elsewhere.
  • Replacement check: Recording both module and terminal references prevents visually similar variants from being mixed.
  • Non-incendive option: The NI version supports documented Zone 2 and Class I Division 2 configurations.
  • System approval: Area suitability depends on the complete module-terminal combination and control drawing.
  • Wiring method: Cable, grounding and field-circuit practice must follow the applicable installation document.
  • Site verification: Local classification and approval requirements remain part of the project selection.
  • Process I/O termination: Connects field circuits to supported PAC8000 analog or discrete modules.
  • Zone 2 cabinets: Serves documented non-incendive installations when the complete combination is approved.
  • Class I Division 2 panels: Provides the specified terminal variant for systems built to the relevant control drawing.
  • Legacy maintenance: Restores the installed unfused field interface identified by the exact model.
Description
Field conductors connect to a compatible PAC8000 I/O module through 8601-FT-NI, a non-incendive terminal assembly for installations covered by the associated control documentation. Its removable termination format supports structured cabinet wiring and module service.

The unfused channel paths in 8601-FT-NI retain the direct field connection defined for the selected I/O module. Voltage, current, conductor size and terminal keying still depend on the complete module-terminal combination rather than the terminal name alone.

Area suitability is established by the approved system drawing, connected equipment and site classification. Apter Power can help compare those records with 8601-FT-NI so the quoted terminal matches both the electrical interface and installation basis.
Alternative Names
8601 FT NI 8601-FT-NI 8601FTNI 8601 FT-NI Emerson 8601-FT-NI PAC8000 8601-FT-NI 8601 FT/NI 8601-FT NI
Technical notes
Area-use note: 8601-FT-NI is a non-incendive field terminal, but its name alone does not establish approval for every Zone 2 or Class I Division 2 installation. The paired I/O module, wiring method and control drawing remain decisive. Apter Power can review these references before quotation to support a compliant selection.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can 8601-FT-NI replace a standard PAC8000 terminal in a Zone 2 cabinet?
It is intended for non-incendive applications, but the paired I/O module, terminal key and approved control drawing must support the complete combination.
How do I know whether 8601-FT-NI matches the installed I/O module?
Compare the module data sheet, terminal keying and channel assignment with the cabinet records. Apter Power can review both part numbers before quotation.
What should be checked when field wires do not seat securely in 8601-FT-NI?
Confirm that conductor size and preparation fit the published 0.14–2.5 mm² range, then inspect the terminal condition without forcing an oversized conductor.
Does 8601-FT-NI provide individual channel fuse protection?
This version is unfused. If the circuit requires channel fuses, a supported fused terminal should be selected for the specific I/O module and area classification.
Which documents are useful when 8601-FT-NI is required for a hazardous-area project?
Provide the I/O module reference, area classification, control drawing, field-circuit details and local approval requirements for a configuration review.
What should an RFQ for 8601-FT-NI include to avoid receiving the wrong terminal?
Include the host module, required terminal key, channel wiring, unfused requirement and installation-area documentation.