Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides option review, technical records, sourcing support, and compatibility guidance for this configured assembly.

3051DP1A62A1AB4M5B4K8HR5

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson 3051DP1A62A1AB4M5B4K8HR5 is a low-range differential-pressure transmitter with HART, display, and mounting selections for established process loops.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 3051DP1A62A1AB4M5B4K8HR5
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3051DP1A62A1AB4M5B4K8HR5

  • Manufacturer:
    Emerson
  • Part Number:
    3051DP1A62A1AB4M5B4K8HR5
  • Product Family:
    Rosemount
  • Product Type:
    Rosemount Configured Differential Pressure Transmitter
  • Stock:
    1
  • Measurement Reference:
    Differential Pressure
  • Sensor Range:
    Range 1: -25 to +25 inH2O
  • Analog Output:
    4–20 mA HART Revision 5
  • Process Interface:
    traditional 3051DP flange
  • Process-Port Thread:
    1/4-18 NPT on the transmitter flange
  • Flange-Adapter Connection:
    1/2-14 NPT Class 2 when official flange adapters are fitted
  • External Power Supply:
    10.5-42.4 Vdc at the transmitter terminals
  • HART Communication Load:
    250 ohms minimum
  • Permitted AC Noise:
    0.2 V peak-to-peak maximum for communication troubleshooting
  • Configuration Protocol:
    HART using a compatible Field Communicator or host
  • Configurable Range Values:
    Lower and upper range values can be reranged within the sensor limits
  • Transfer Function:
    Linear or square-root selection for the traditional 4-20 mA output
  • Damping:
    Software-configurable damping for the primary variable
  • Engineering Units:
    Pressure engineering units are configurable through the HART interface
  • Loop Test:
    Fixed analog-output loop test is available for commissioning
  • Analog Output Trim:
    Digital-to-analog output trim is supported
  • Zero Trim:
    Single-point zero offset trim is supported after final mounting
  • Sensor Trim:
    Two-point lower and upper sensor trim is supported
  • Factory Trim Recall:
    Factory sensor trim can be recalled on 4-20 mA output units
  • Write Protection:
    Security setting prevents changes to transmitter configuration
  • Multidrop Addressing:
    HART multidrop addressing follows the installed device revision and host configuration
  • Diagnostic Indication:
    Sensor, electronics, configuration, pressure-limit, temperature-limit, saturation, and loop-test conditions are reported
  • Installation Requirement:
    All four flange bolts must be installed and tightened before pressure is applied
  • Impulse-Piping Requirement:
    High- and low-side impulse legs must preserve correct routing, equal head, and process isolation
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Communication Configuration Certifications

Features:

  • The complete option string preserves a defined combination of sensing, mechanical, display, and communication choices.
  • Saving the tag, damping, range values, trim history, and alarm direction prevents configuration loss during replacement.
  • Cable entries and covers must remain sealed after display access or communicator work.
The current record covers a fully configured differential-pressure transmitter with display and mounting selections, and omitted choices are not inferred from nearby family codes.

The operating application is sensitive differential-pressure duties in established process loops. The option package supports local indication and HART Revision 5 access while retaining the specified hazardous-location approval.

Replacement planning must reconcile every suffix, the installed bracket, display orientation, flange hardware, HART host support, and approval label. Record the approval marking, bracket orientation, electrical entry, and calibrated range before removal.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson Rosemount 3051DP1A62A1AB4M5B4K8HR5: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Monitors small process-pressure differences where impulse-line balance and zero stability are controlled by the installation.
  • Supports low differential flow measurement with a correctly selected primary element and host-side characterization.
  • Serves hydrostatic level loops that require the original mounting, display, and certified enclosure arrangement to be retained.
  • The configured output carries the process variable to the receiving channel while service data remains available to a compatible maintenance host.
  • Digital access is used for commissioning checks without replacing the primary control-loop measurement.
  • Protocol revision and loop conditions are verified before sensitive differential-pressure service is returned to operation.
  • The saved setup records tag, engineering units, damping, range values, and alarm direction.
  • A valid applied reference is required before zero or sensor trim is accepted.
  • Configuration restoration follows hardware identity checks for this configured low-span DP assembly.
  • The actual nameplate approval identifies the hazardous-location use permitted for the supplied assembly.
  • Installation follows the control drawing associated with that approval code.
  • Certified cable entries and closure hardware are preserved around this configured low-span DP assembly.
Description
3051DP1A62A1AB4M5B4K8HR5 identifies a Rosemount 3051 assembly built as a fully configured differential-pressure transmitter with display and mounting selections. Unlisted option choices are not inferred from nearby catalog numbers.

Its operating scope covers sensitive differential-pressure duties in established process loops. It supplies a differential-pressure variable while retaining digital access for commissioning and maintenance.

A supply comparison must cover every suffix, the installed bracket, display orientation, flange hardware, HART host support, and approval label. Resolve any difference before the unit is released for installation.
Alternative Names
3051DP1A62A1AB4M5B4K8HR5 3051DP-1A62A1AB4M5B4K8HR5 3051DP 1A62A1AB4M5B4K8HR5 Rosemount 3051DP1A62A1AB4M5B4K8HR5 Emerson 3051DP1A62A1AB4M5B4K8HR5 EMR 3051DP1A62A1AB4M5B4K8HR5 Emerson Rosemount 3051DP1A62A1AB4M5B4K8HR5 Rosemount 3051DP1A62A1AB4M5B4K8HR5 Differential Pressure Transmitter
Technical notes
3051DP1A62A1AB4M5B4K8HR5 requires both impulse legs to be isolated, bled, and equalized before restoring the saved HART Revision 5 range and alarm direction.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must the complete suffix sequence be retained for 3051DP1A62A1AB4M5B4K8HR5?
The suffixes identify configuration choices that affect mechanics, indication, communication, and approvals; omitting one can change the supplied assembly.
What host-side HART detail can block a like-for-like change to 3051DP1A62A1AB4M5B4K8HR5?
Confirm that the existing host and maintenance tools support the configured HART revision and preserve the required analog-loop behavior.
Which differential-pressure duty is appropriate for 3051DP1A62A1AB4M5B4K8HR5?
It suits low differential-pressure service only after the manifold, impulse piping, process media, and calibrated operating window are verified.
What project data lets Apter assess configured availability for 3051DP1A62A1AB4M5B4K8HR5?
Provide the full ordering string, nameplate photographs, required condition, quantity, destination, and the project delivery window.
Can the suffix set on 3051DP1A62A1AB4M5B4K8HR5 be shortened when ordering a replacement?
No suffix may be dropped for convenience; compare every encoded option with the installed unit and the project documentation.
What manual set is needed to restore the saved setup of 3051DP1A62A1AB4M5B4K8HR5?
Retain the relevant Rosemount reference manual, option tables, loop drawing, calibration sheet, and exported device setup.

Product Browsing History