3051TA1A

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson 3051TA1A is an in-line absolute-pressure transmitter with a sealed reference for absolute-pressure and vacuum-related process measurement.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 3051TA1A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3051TA1A

  • Manufacturer:
    Emerson
  • Part Number:
    3051TA1A
  • Product Family:
    Rosemount
  • Product Type:
    Rosemount In-Line Absolute Pressure Transmitter
  • Stock:
    1
  • Measurement Reference:
    Absolute pressure
  • Sensor Range Code:
    1
  • Minimum Calibrated Span:
    0.30 psi (20.68 mbar)
  • Upper Sensor Limit:
    +30 psi (+2.06 bar)
  • Lower Sensor Limit:
    0 psia (0 bar absolute)
  • Reference Accuracy:
    +/-0.04% of span under stated reference conditions
  • Long-Term Stability:
    +/-0.2% of URL for 10 years under stated conditions
  • Total Response Time:
    100 ms nominal
  • Mounting-Position Effect:
    Zero shift up to +/-2.5 inH2O (6.22 mbar), calibratable; no span effect
  • Overpressure Limit:
    750 psi (51.7 bar)
  • Burst Pressure:
    11016 psi (759.5 bar) for ranges 0-4
  • Silicone-Fill Process Temperature:
    -40 to +121 degrees C (-40 to +250 degrees F)
  • Inert-Fill Process Temperature:
    -30 to +121 degrees C (-22 to +250 degrees F)
  • Process Connection Options:
    1/2-14 NPT female or G1/2 A DIN 16288 male for range 1-4, as selected by the completed code
  • Electrical Entries:
    1/2-14 NPT, G1/2, or M20 x 1.5 according to the completed housing code
  • Base Transmitter Weight:
    3.0 lb (1.4 kg) without options
  • Analog Output:
    Two-wire 4-20 mA
  • Digital Communication:
    HART digital signal superimposed on the analog output
  • Transfer Function:
    User-selectable linear or square-root output
  • External Power Supply:
    10.5-42.4 Vdc with no load
  • HART Communication Load:
    250 ohms minimum
  • Maximum Loop Resistance:
    43.5 x (power-supply voltage - 10.5) ohms
  • Update Rate:
    22 updates per second
  • Dead Time:
    45 ms nominal
  • Ambient Temperature:
    -40 to +85 degrees C (-40 to +185 degrees F)
  • Storage Temperature:
    -46 to +110 degrees C (-50 to +230 degrees F)
  • Humidity Limit:
    0-100% relative humidity
  • Turn-On Time:
    Less than 2 seconds for HART output
  • Software Damping:
    0-60 seconds, user-selectable for one time constant
  • Volumetric Displacement:
    Less than 0.005 in3 (0.08 cm3)
  • Vibration Effect:
    Less than +/-0.1% of URL under the IEC 60770-1 high-vibration test
  • Power-Supply Effect:
    Less than +/-0.005% of calibrated span per volt
  • Electromagnetic Compatibility:
    Meets EN 61326 industrial requirements and NAMUR NE 21
  • Supported Process Media:
    Liquid, gas, and vapor service
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Interoperability Configuration & Programming Compliance

Features:

  • The sealed reference allows pressure to be measured independently of local atmospheric variation.
  • A valid absolute-pressure reference and leak-tight process connection are essential when checking zero or calibration.
  • Temperature changes and vacuum-side installation practices must remain within the completed sensor and fill-fluid limits.
This order identifies an in-line absolute-pressure transmitter with a sealed measurement reference; the physical nameplate governs the exact assembly supplied.

Its assigned work is absolute-pressure and vacuum-related process measurement. Range 1 provides absolute-pressure measurement from a sealed vacuum reference rather than local atmosphere.

Before installation, verify the process connection, wetted materials, sensor fill, housing, output, vacuum service, indication, and approvals. Use a suitable absolute reference when validating calibration or low-pressure performance.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson Rosemount 3051TA1A: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Measures absolute pressure in vacuum vessels or process systems where atmospheric-reference variation is unacceptable.
  • Supports vapor-pressure or low-absolute-pressure monitoring with a leak-tight in-line process connection.
  • Provides absolute-pressure input for control calculations that require a sealed rather than vented reference.
  • Host communication is proven without changing the primary measurement behavior of the loop.
  • Process hardware integration is verified through drawings, part records, and seal compatibility.
  • A functional test confirms interoperability throughout absolute and vacuum-related measurement.
  • The asset record preserves range values, engineering units, damping, trim status, and failure behavior.
  • Programming begins from a verified hardware identity and an approved reference condition.
  • Changed parameters are validated at the host before this in-line absolute-pressure configuration returns to automatic control.
  • The supplied approval suffix determines the applicable protection method and installation conditions.
  • Pressure components remain within the material and rating scope accepted by the project.
  • Conformance review includes the actual process connection, sensor fill, vacuum practice, and approvals evidence.
Description
3051TA1A is an in-line absolute-pressure transmitter with a sealed measurement reference in the Rosemount 3051 range. The complete nameplate is the controlling record for the supplied assembly.

The installed duty is absolute-pressure and vacuum-related process measurement. It provides the absolute process variable needed by control and monitoring applications that cannot use a vented gauge reference.

Before replacement, confirm the process connection, wetted materials, sensor fill, housing, output, vacuum service, indication, and approvals. Record the final comparison in the maintenance documentation.
Alternative Names
3051TA1A 3051TA-1A 3051TA 1A Rosemount 3051TA1A Emerson 3051TA1A EMR 3051TA1A Emerson Rosemount 3051TA1A Rosemount 3051TA1A In-Line Absolute Pressure Transmitter
Technical notes
3051TA1A calibration requires a valid absolute-pressure reference; atmospheric venting is not a zero reference, and the Range 1 process connection must be confirmed.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must 3051TA1A be calibrated against an absolute-pressure reference?
Its sealed measurement reference requires a known absolute standard; an ordinary vented gauge source cannot establish the correct reference.
Which vacuum-side installation concern matters for 3051TA1A?
Confirm leak-tight process connection, compatible wetted materials, vacuum practice, sensor orientation, and the receiving loop.
In which absolute-pressure duty would 3051TA1A be selected?
Select it for absolute or vacuum-related duty where the control calculation cannot rely on local atmospheric pressure.
What calibration scope should accompany a request for 3051TA1A?
Provide the calibration scope, target units, condition, quantity, destination, delivery requirement, and complete nameplate.
Why is a gauge transmitter not a functional replacement for 3051TA1A?
A gauge transmitter uses a different pressure reference and is not functionally equivalent without redesigning the measurement.
Which data-sheet section confirms the measurement reference for 3051TA1A?
Review the Rosemount 3051T data sheet and reference manual sections for absolute measurement, mounting, and calibration.

Product Browsing History