Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports 369B1842G5004 documentation, compatibility review and quotation.

369B1842G5004

/ 4.9
1001 reviews | Need a Specific Revision?
GE Vernova 369B1842G5004 is the MHO50 Nexus eight-channel mA/V analog-output module with HART capability for industrial process-control panels.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 369B1842G5004
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 369B1842G5004

  • Manufacturer:
    General Electric
  • Part Number:
    369B1842G5004
  • Product Family:
    GE Intelligent Platforms
  • Product Type:
    MHO50 Nexus 8-Channel HART Analog Output Module
  • Stock:
    1
  • Product Family:
    Nexus OnCore Control System
  • Nexus Model:
    MHO50
  • Catalogue Number:
    369B1842G5004
  • Channels:
    8
  • Signal Type:
    mA/V analog output
  • Communication:
    HART
  • Input Voltage:
    24 VDC
  • Input Power:
    6.7 W
  • Mounting:
    Panel mounted in end-use enclosure
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Connectivity Control Certifications

Features:

  • Provides eight mA/V analog-output channels in the Nexus platform.
  • Supports HART communication on the documented MHO50 output function.
  • Operates from a 24 VDC supply with 6.7 W rated input power.
The current ordering configuration is 369B1842G5004, mapped by GE Vernova to the MHO50 Nexus analog-output module.

It processes controller commands and drives eight analog output channels for industrial process-control and data-acquisition functions.

Verify the matching Nexus base, output signal selection, 24 VDC source and enclosure certification before installation.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for GE Vernova 369B1842G5004: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Drives eight analog actuator or final-control signals in a Nexus process-control panel.
  • Supports HART-enabled analog output loops where the MHO50 channel design is specified.
  • Provides intelligent output processing for documented Nexus industrial-control assemblies.
  • HART capability is integrated with the documented eight-channel analog-output function.
  • The module communicates with other Nexus control modules inside the panel-mounted system.
  • Field-loop connection must follow the signal type and channel wiring assigned to the MHO50 base.
  • Eight mA/V channels deliver controller output commands to connected field circuits.
  • The on-module processor supports intelligent processing of commanded output data.
  • Each channel must be configured for the output range used by the connected final element.
  • The cited certificate covers MHO50 as a panel-mounted industrial process-control module.
  • Hazardous-area installation requires an ATEX-certified enclosure with at least IP54 protection.
  • The end-use enclosure must be tool secured and grounded according to the certificate conditions.
Description
369B1842G5004 is the GE Vernova catalogue number for the MHO50 Nexus analog-output module. The certified configuration provides eight mA/V output channels with HART capability.

The module contains the common Nexus processor subsystem and an output-specific acquisition circuit for intelligent data processing. Its documented supply is 24 VDC with 6.7 W input power.

Install it only in the specified panel and enclosure arrangement, then match the base, channel signal type and application configuration. Hazardous-location use requires the certificate conditions, grounding and protected enclosure to be satisfied.
Alternative Names
369B1842G5004 GE Vernova 369B1842G5004 369B1842 G5004 369B1842-G5004 369B1842G 5004 369B1842G-5004 GE Vernova Nexus OnCore Control System 369B1842G5004 GE Vernova MHO50 Nexus 8-Channel HART Analog Output Module
Technical notes
Install 369B1842G5004 in the certified tool-secured enclosure with required ingress protection, and disconnect the module only after power removal or area safety confirmation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which functional identity must be preserved when specifying 369B1842G5004?
The complete catalogue number must remain associated with the MHO50 eight-channel HART analog-output function and its certified 24 VDC Nexus module construction.
How should HART field-device compatibility be evaluated for a 369B1842G5004 installation?
Review the complete loop design, field-device HART requirements, load, cabinet interface and host-system configuration rather than relying on protocol support alone.
Which control-panel duty best matches the 369B1842G5004 output architecture?
It is suited to a Nexus panel that must command multiple analog final elements while retaining HART communication on the documented output channels.
What project details make a 369B1842G5004 sourcing check actionable?
Provide the complete catalogue number, MHO50 designation, installed enclosure or certification requirement, required quantity, destination and requested delivery date.
Can another 369B1842 group number be treated as the same module as 369B1842G5004?
No; the full G5004 catalogue number defines the ordered module variant, and another group number requires a documented equivalence review.
Which manufacturer certificates should accompany a hazardous-area inquiry for 369B1842G5004?
Request the applicable GE Vernova OnCore declaration 157M7002 and ATEX certificate 157M0728, then confirm the end-use enclosure conditions for the project.