Features:
- Performance configuration with a 933 MHz processor and 256 MB of memory.
- Read/write CD-ROM media in an unbundled Windows 2000 station.
- Compact 12.1-inch TFT touchscreen for cabinet-mounted operator access.
The 800 x 600 front display presents 256K colors and uses a five-wire resistive touch surface linked internally to COM4.
Its front controls provide soft-keyboard access, task switching, right-mouse emulation, hot-key operation, and brightness adjustment without an external keypad.
A 330 x 268 mm panel outline and two shared ISA/PCI positions suit compact enclosures that still require local expansion.
Apter Power can assist with quotation requests and official documentation for the General Electric IC5002TBW0000 12.1-Inch Performance Unbundled Intelligence Panel PC.
General Electric IC5002TBW0000 12.1-Inch Performance Unbundled Intelligence Panel PC Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
IC5002TBW0000 Front-Panel Interaction
- Touch interface: The five-wire resistive surface is internally assigned to COM4.
- Control keys: Five front functions provide soft keyboard, task change, hot-key, right-click, and brightness access.
- Pointer use: The touchscreen and a PS/2 mouse can operate at the same time.
- Calibration: The ELO utility aligns pointer movement with the touched screen position.
IC5002TBW0000 Read/Write Media Handling
- Drive type: The performance order configuration includes a read/write CD-ROM drive.
- Utility software: Writing files requires the supplied CD-writer utility and its operating instructions.
- Driver media: The SBC driver disc contains chipset, graphics, and support files.
- Removal: Optical media should be removed before the documented restart steps.
IC5002TBW0000 Ethernet Commissioning
- Adapters: Two independent 10/100BaseT RJ45 interfaces are available.
- Addressing: Windows 2000 setup supports fixed TCP/IP addressing or DHCP.
- DHCP condition: The station must be attached to a DHCP-enabled network when that mode is selected.
- Workgroup data: Commissioning includes the required workgroup or domain information.
IC5002TBW0000 Thermal Installation
- Panel opening: The 12.1-inch chassis uses the documented cabinet cutout and mounting hardware.
- Air space: Cooling requires open space at the top, bottom, and sides of the enclosure.
- Card heat: Installed expansion cards must remain within the 20 W total added load.
- Ambient limit: The surrounding cabinet temperature must stay within the 0 to 40 deg C operating range.