Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Configuration verification required
    Apter Power can provide IS200EDEXG1AFA for ex2100 de-excitation board replacement and installed-system maintenance; confirm the complete configuration and delivery requirements before ordering.

IS200EDEXG1AFA

/ 4.9
1001 reviews | Need a Specific Revision?
IS200EDEXG1AFA is a GE Vernova EX2100 De-Excitation Board for ex2100 de-excitation board replacement and installed-system maintenance.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for IS200EDEXG1AFA
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IS200EDEXG1AFA

  • Manufacturer:
    General Electric
  • Part Number:
    IS200EDEXG1AFA
  • Product Family:
    GE Mark VI Gas Turbine Control
  • Product Type:
    EX2100 De-Excitation Board
  • Stock:
    1
  • Hardware function:
    EX2100 De-Excitation Board
  • Control platform:
    GE EX2100 excitation control
  • Interface scope:
    Board- or module-specific interfaces for the GE EX2100 excitation control installation
  • Primary application:
    EX2100 De-Excitation Board replacement and installed-system maintenance
  • Hardware identity:
    IS200EDEXG1AFA
  • Replacement basis:
    Exact hardware and installed configuration match
  • Commissioning checks:
    Power, grounding, wiring, diagnostics and channel response
  • Documentation basis:
    OEM-authored family reference plus installed nameplate
  • Weight:
    0.25 kg
  • Estimated shipping dimensions:
    22.8x15.2x3.5cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Hardware Data Compatibility Commissioning Installation Check

Product overview:

  • EX2100 De-Excitation Board
  • GE EX2100 excitation control
  • EX2100 De-Excitation Board replacement and installed-system maintenance

IS200EDEXG1AFA provides board- or module-specific interfaces for the ge ex2100 excitation control installation.

Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.

Apter Power can provide IS200EDEXG1AFA for quotation and technical review.

Hardware data:

  • Exact identity: IS200EDEXG1AFA
  • Function: EX2100 De-Excitation Board
  • Platform: GE EX2100 excitation control

Board- or module-specific interfaces for the GE EX2100 excitation control installation

Compatibility review:

  • Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
  • Compare connectors, terminal assignments and configured options
  • Use an engineered migration when revisions are not interchangeable

IS200EDEXG1AFA should be matched to the complete installed control assembly.

Commissioning checks:

  • Verify power and protective isolation
  • Confirm grounding, shielding and field wiring
  • Test diagnostics and functional response

Record baseline results for IS200EDEXG1AFA before returning the machine to service.

Installation check:

  • Photograph the original hardware and settings
  • Follow site lockout/tagout and ESD controls
  • Inspect connectors, torque and ventilation

Do not energize IS200EDEXG1AFA until wiring and configuration reviews are complete.

Description

IS200EDEXG1AFA is a GE Vernova EX2100 De-Excitation Board associated with the GE EX2100 excitation control platform. Its documented role is ex2100 de-excitation board replacement and installed-system maintenance, with board- or module-specific interfaces for the ge ex2100 excitation control installation.

IS200EDEXG1AFA must be treated as one complete hardware and configuration reference. The board or module, terminal arrangement, firmware and connected control hardware must match the installed cabinet drawings; a similar family code does not establish electrical or functional interchangeability.

Before installing IS200EDEXG1AFA, isolate power, photograph the existing nameplate and connectors, record rack position and jumper settings, compare terminal assignments, and verify power, grounding, field wiring and diagnostics during commissioning.

Revisions

Revision Part #

Also known as

IS200EDEXG1AEA
IS200EDEXG1A-EA, Series -EA, Rev -EA
Alternative Names
IS200EDEXG1AFA GE Vernova IS200EDEXG1AFA IS200EDEXG1AFA EX2100 De-Excitation Board IS200EDEXG1AFA replacement module IS200EDEXG1AFA spare part IS200EDEXG1AFA datasheet IS200EDEXG1AFA industrial control component 7 IS200EDEXG1AFA industrial control component 8
Technical notes
IS200EDEXG1AFA is the exact ex2100 de-excitation board reference for the GE EX2100 excitation control installation. Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which installed details must match before replacing IS200EDEXG1AFA?
Match the complete IS200EDEXG1AFA nameplate, hardware revision, firmware, rack or cabinet position, connectors and terminal assignments.
How should the interface for IS200EDEXG1AFA be verified?
Use the system drawings to verify board- or module-specific interfaces for the ge ex2100 excitation control installation, including signal type, polarity, reference potential and grounding.
What should be checked before applying power to IS200EDEXG1AFA?
Confirm supply voltage, protective devices, connector keying, jumper positions, field isolation and cabinet grounding before energizing.
How is IS200EDEXG1AFA commissioned after installation?
Check the ex2100 de-excitation board replacement and installed-system maintenance function channel by channel and compare diagnostics, feedback and commanded states with the original configuration.
Can a similar family board replace IS200EDEXG1AFA?
Not by part-family similarity alone. Electrical interfaces, firmware, revision, options and configured function must be reviewed as one replacement package.
What manual should be used for IS200EDEXG1AFA?
Use the product-specific Apter Power datasheet together with the latest applicable OEM system manual and the installed cabinet drawings.
What information is needed for a quotation for IS200EDEXG1AFA?
Provide clear front and rear nameplate photos, complete suffixes, quantity, installed platform, failure symptoms and delivery destination.
How should a stored spare for IS200EDEXG1AFA be evaluated?
Inspect packaging and connectors, review storage history, verify firmware and revision, and perform controlled bench or cabinet tests before return to service.