Features:
- Sixteen three-wire RTD channels are acquired through one VME processing board.
- Normal and fast scan choices support different temperature-response and noise-rejection needs.
- Automatic fault isolation removes an out-of-range loop without suppressing the remaining channels.
The two eight-channel groups in IS200VRTDH1D can be tuned independently for their installed sensor population, allowing one rack position to support temperature loops with different gain and timing requirements.
A 14-bit conversion path preserves useful temperature resolution while the Mark VI software applies the selected RTD curve and system limits to each configured input.
Maintenance teams can use the board diagnostics to separate an abnormal field circuit from healthy neighboring measurements and to control whether a repaired point returns automatically or manually.
For legacy Mark VI temperature-monitoring projects, Apter Power can source and support General Electric IS200VRTDH1D RTD Input Board beyond the manufacturer lifecycle.
General Electric IS200VRTDH1D RTD Input Board Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
IS200VRTDH1D Channel Configuration
- RTD selection: Assign the applicable platinum, copper, nickel, or ohms mode to every used input.
- Sampling choice: Select filtered normal scanning or 25 Hz fast scanning according to the required response and interference environment.
- Group gain: Configure each eight-channel group for normal, higher-accuracy, or copper-RTD gain where the sensor range permits.
- System limits: Enable and define software alarm limits independently from the board hardware out-of-range checks.
IS200VRTDH1D RTD Signal Processing
- VCO conversion: The conditioned RTD input is converted into a counted-frequency representation for digital processing.
- Grouped acquisition: Excitation and signal paths are sampled in two independent groups of eight inputs.
- Software linearization: Supported RTD resistance curves are converted into temperature engineering values in the Mark VI processing chain.
- Noise rejection: Normal scanning can be synchronized to the selected 50 or 60 Hz power-system filter.
IS200VRTDH1D Fault Diagnosis
- Open or short circuit: An input outside the hardware limits points to a field-loop, terminal, or sensor condition that requires isolation.
- Scan removal: A failed loop is removed from acquisition so it does not adversely affect the other temperature channels.
- Recovery path: Auto Reset can restore a repaired point after the specified interval, while manual reinstatement remains available.
- Common-cause review: Simultaneous errors across a group should trigger inspection of shared termination, cable shielding, and group settings.
IS200VRTDH1D Product Applications
- Turbine bearing temperatures: Acquires three-wire RTD measurements assigned to bearing and rotating-equipment temperature monitoring.
- Generator auxiliaries: Brings applicable equipment temperature loops into the Mark VI controller when the project I/O schedule assigns VRTD channels.
- Steam-turbine supervision: Supports the temperature-monitoring portion of the documented Mark VI governor and protection architecture.
- Condition alarms: Supplies digitized temperature values for application logic that compares operating conditions with configured limits.