IC754CSF15CTD

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC754CSF15CTD is a fully loaded 15-inch QuickPanel Control color touch panel for integrated HMI and local control applications.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC754CSF15CTD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC754CSF15CTD

  • Manufacturer:
    General Electric
  • Part Number:
    IC754CSF15CTD
  • Product Family:
    GE QuickPanel
  • Product Type:
    QuickPanel Control Fully Loaded 15-Inch Color Touch Panel
  • Stock:
    1
  • Display:
    15-inch color TFT
  • Resolution:
    1024 x 768 pixels
  • Display Colors:
    65,536
  • Display Luminance:
    500 nits
  • Touchscreen:
    12-bit resistive, 1024 x 768 calibrated cells
  • Processor:
    Intel XScale PXA255, 400 MHz
  • Operating System:
    Microsoft Windows CE
  • DRAM:
    64 MB
  • Flash Memory:
    64 MB
  • Retentive Memory:
    512 KB battery-backed SRAM
  • Ethernet:
    Two IEEE 802.3 10/100BaseTX ports
  • Serial Ports:
    COM1 EIA232C/EIA485 and COM2 EIA232C
  • USB:
    USB 1.1 host support
  • CompactFlash:
    One Type I/II slot
  • Fieldbus Expansion:
    One slot
  • Input Voltage:
    9.6 to 28.8 VDC
  • Power Consumption:
    48 W
  • Operating Temperature:
    0 to 50 °C
  • Storage Temperature:
    -20 to 60 °C
  • Panel Rating:
    NEMA 4 and 4X; IP66 equivalent
  • Backup Battery:
    BR2032, 3 V, 190 mAh
  • Weight:
    10.3 lbs (4.67 kg)
  • Estimated shipping dimensions:
    377.3 x 304.0 x 70.7 mm
  • Tariff Code:
    8537109170
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Panel Operation Network Paths Data Handling Service Checks

Features:

  • Runs visualization and embedded control functions on a single fully loaded 15-inch platform.
  • Offers a bright 1024 x 768 color touch surface for detailed factory-floor operation.
  • Connects through two Ethernet channels, two serial channels, USB, CompactFlash, and an expansion bus.
The Control variant is designed for local or distributed machine control where the operator interface and the logic project share one engineered device.

Machine Edition provides the project framework, while Windows CE supplies the system controls used for network setup, storage management, clock adjustment, and maintenance utilities.

The 15-inch enclosure uses perimeter clamps and a sealed front assembly; the installed cabinet must still control heat, contamination, wiring clearance, and access to the rear service components.

General Electric IC754CSF15CTD QuickPanel Control Fully Loaded 15-Inch Color Touch Panel is available for Apter Power quotation and official-documentation support.
General Electric IC754CSF15CTD QuickPanel Control Fully Loaded 15-Inch Color Touch Panel Manuals, Datasheets, Links

IC754CSF15CTD Operator Functions

  • XGA workspace: The 1024 x 768 screen supports detailed process displays and navigation.
  • Touch input: The full resistive surface is calibrated to the display cell grid.
  • Brightness: The Display control adjusts luminance for the operator environment.
  • Soft keyboard: Windows CE provides an on-screen input panel when text entry is required.

IC754CSF15CTD Communication Routing

  • LAN1 and LAN2: Two independent Ethernet ports can separate machine and supervisory traffic.
  • COM1: The primary serial channel supports EIA232C or EIA485.
  • COM2: A second EIA232C port serves another serial device or service connection.
  • Fieldbus: The expansion slot adds a supported industrial-network interface.

IC754CSF15CTD Runtime Data Storage

  • Flash files: Applications and the operating image remain without external power.
  • Working memory: DRAM holds executing programs and temporary objects.
  • Retained area: BBSRAM preserves selected information while the battery is healthy.
  • Removable media: CF and USB storage support project copies and service files.

IC754CSF15CTD Maintenance Sequence

  • Project backup: Secure the current application before hardware removal.
  • Network record: Document both LAN addresses and any serial configuration.
  • Battery state: Check the low-battery indication before relying on retained storage.
  • Expansion record: Identify the installed fieldbus module and its cable arrangement.
Description
The dual Ethernet and dual serial arrangement on IC754CSF15CTD separates plant, controller, and service connections. A rear fieldbus position further extends the control role, while the 9.6 to 28.8 VDC input accommodates typical 24 V industrial supplies.

IC754CSF15CTD is a fully loaded member of the 15-inch QuickPanel Control platform identified in GFK-2402D. It combines a large operator display with embedded control capability for machines that benefit from a single visualization and logic device.

Runtime resources in IC754CSF15CTD include 64 MB of DRAM, 64 MB of flash, and 512 KB of battery-backed SRAM. CompactFlash and USB storage can be used for controlled project movement, logs, or approved external files.

The front of IC754CSF15CTD uses a 15-inch TFT panel with 1024 x 768 resolution, 65,536 colors, and 500-nit luminance. A calibrated resistive touch surface covers the full image area and supports normal operation without a physical keyboard.
Alternative Names
IC754 CSF15 CTD IC754-CSF15-CTD IC754 CSF-15CTD GE Fanuc IC754CSF15CTD GE Intelligent Platforms IC754CSF15CTD QuickPanel Control IC754CSF15CTD 1C754CSF15CTD IC754CSFISCTD
Technical notes
The IC754CSF15CTD FTP server supports standard FTP and explicit FTPS; it does not support SFTP or implicit FTPS connections.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should an IC754CSF15CTD replacement project be prepared?
Back up the IC754CSF15CTD Machine Edition application, retained files, network settings, serial parameters, and fieldbus configuration before disconnecting the original panel.
Why does IC754CSF15CTD lose only one network connection?
LAN1 and LAN2 on IC754CSF15CTD are configured independently; inspect the failed port address, route, cable, link LEDs, and duplicate-IP conditions.
What should be checked when IC754CSF15CTD retained values reset?
Review the IC754CSF15CTD battery warning, SRAM use, application data path, and the maintenance history of the BR2032 backup cell.
How can IC754CSF15CTD text be entered without an external keyboard?
Open the Windows CE Soft Input Panel on IC754CSF15CTD, move it clear of the active field, and use the touch surface for text entry.
Why might a CompactFlash card be inaccessible on IC754CSF15CTD?
Check IC754CSF15CTD card seating, supported voltage and type, free capacity, file-system condition, and whether the card was removed during a write.
What should be recorded before servicing an IC754CSF15CTD fieldbus option?
Record the IC754CSF15CTD module type, network address, cable orientation, termination, and project assignment before power is isolated.
How can IC754CSF15CTD overheating risk be reduced?
Keep IC754CSF15CTD within the documented ambient range, provide enclosure airflow, separate heat sources, and avoid blocking rear ventilation or cable space.