Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can provide IC754VSI06MTD quotation assistance, pricing information, and access to the applicable official General Electric technical documentation.

IC754VSI06MTD

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC754VSI06MTD is a QuickPanel View Intermediate 6-Inch Monochrome Touch Operator Interface that pairs a 5.7-inch display with CIMPLICITY Machine Edition View Intermediate for factory-floor HMI tasks.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC754VSI06MTD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC754VSI06MTD

  • Manufacturer:
    General Electric
  • Part Number:
    IC754VSI06MTD
  • Product Family:
    GE QuickPanel
  • Product Type:
    QuickPanel View Intermediate 6-Inch Monochrome Touch Operator Interface
  • Stock:
    1
  • Display Type:
    6-inch monochrome FSTN
  • Viewable Size:
    5.75 in (14.6 cm) diagonal
  • Display Resolution:
    320 x 240 pixels
  • Gray Levels:
    256
  • Touchscreen:
    12-bit resistive, 320 x 240 calibrated cells
  • Processor:
    Intel XScale PXA255, 300 MHz
  • Operating System:
    Microsoft Windows CE.NET
  • DRAM:
    32 MB, expandable to 64 MB or 96 MB total
  • Flash Memory:
    32 MB
  • Retentive Memory:
    512 KB battery-backed SRAM
  • Ethernet:
    IEEE 802.3 10/100BaseT, RJ45
  • Serial Port:
    COM1 EIA232C/EIA485, DB25S, 300 to 115200 bps
  • CompactFlash:
    One Type 2 slot
  • Expansion Bus:
    One slot
  • Input Voltage:
    10.8 to 30 VDC
  • Real Power:
    12 W
  • Operating Temperature:
    -10 to 60 °C (14 to 140 °F)
  • Operating Humidity:
    10% to 85%, non-condensing
  • Storage Temperature:
    -20 to 70 °C (-4 to 158 °F)
  • Panel Rating:
    NEMA 4, 4X, and 12 when panel mounted; IP65 equivalent
  • Operational Shock:
    IEC 68-2-27, 15 g for 11 ms
  • Operational Vibration:
    IEC 68-2-6, 10 to 57 Hz displacement and 57 to 500 Hz acceleration
  • Backup Battery:
    CR2032, 3 V, 190 mAh lithium
  • Agency Qualifications:
    UL 508/C-UL, UL 1604/C-UL Class I Division 2 Groups A-D, UL 50, ATEX Group II Category 3, CE
  • Weight:
    2.5 lbs (1.16 kg)
  • Estimated shipping dimensions:
    158 x 126 x 70 mm
  • Tariff Code:
    8537109170
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Connectivity Environment Diagnostics Installation

Features:

  • Combines a monochrome touch interface with CIMPLICITY Machine Edition View Intermediate.
  • Captures historical trend data while the visualization application is running.
  • Supports online language selection and shared tags across Machine Edition applications.
The 5.75-inch display uses passive FSTN construction, 256 gray levels, and a 320 x 240 pixel image area coupled to a calibrated resistive touch surface.

QuickDesigner projects can be migrated into the Machine Edition environment, while the supplied animation-object library shortens development of operator screens for machine functions.

The compact 6-inch format can operate as a stand-alone factory-floor interface or participate in a networked control environment without changing its panel-mounted operator role.

General Electric IC754VSI06MTD QuickPanel View Intermediate 6-Inch Monochrome Touch Operator Interface is available for Apter Power quotation and official-documentation support.
General Electric IC754VSI06MTD QuickPanel View Intermediate 6-Inch Monochrome Touch Operator Interface Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

IC754VSI06MTD Network and Peripheral Interfaces

  • Ethernet access: The auto-negotiating RJ45 port supports Windows CE networking and custom-application communication over IEEE 802.3.
  • Cable selection: A direct connection to a PC uses a crossover cable, while a connection through a LAN hub uses a straight-through cable.
  • Serial operation: COM1 can operate as an EIA232C or EIA485 bidirectional channel for direct, dial-up, or application-created connections.
  • EIA485 wiring: Twisted-pair cable is required, and the supplied termination is enabled at the final network node by linking pins 9 and 10.
  • Fieldbus expansion: Supported options include IC754GEN001 for Genius, IC754DVNS01 for DeviceNet Slave, and IC754PBS01 for PROFIBUS Slave communication.

IC754VSI06MTD Service Environment

  • Monochrome temperature range: Operation is specified from -10 to 60 °C, with storage from -20 to 70 °C.
  • Moisture limits: Both operating and storage humidity are limited to 10% to 85% non-condensing conditions.
  • Panel protection: The front assembly reaches NEMA 4, 4X, and 12 performance when mounted in a comparably rated panel or enclosure.
  • Mechanical endurance: Qualification includes IEC 68-2-6 operational vibration and IEC 68-2-27 shock testing.
  • Hazardous locations: ATEX use requires installation in an IP66-rated panel, while UL 1604 covers Class I, Division 2 Groups A-D locations.

IC754VSI06MTD Status and Protective Functions

  • Power indication: The left front LED is green with power applied and changes to amber if the display backlight fails.
  • Programmable indication: The second front LED can be controlled by the application in green, red, or amber.
  • Battery warning: Windows CE places a Battery Very Low Or Missing icon in the taskbar when the internal backup battery requires attention.
  • Serial protection: The COM1 auxiliary supply on pin 14 is protected by a field-replaceable 1 A fast-blow fuse.
  • Startup control: Only DIP switch 2 is user-adjustable for forcing startup applications; the remaining switches are reserved for factory functions.

IC754VSI06MTD Panel Integration Requirements

  • Panel opening: The enclosure passes through a 156 x 123.5 mm cutout with the specified positive tolerances.
  • Panel thickness: The mounting arrangement accepts panels from 1.6 to 5 mm thick.
  • Bracket loading: The four mounting-bracket screws are tightened within the 0.3 to 0.5 N·m torque range.
  • Seal integrity: The bezel gasket must remain seated and undamaged to preserve the front-panel liquid and dust seal.
  • Expansion access: Remove power and use electrostatic precautions before opening the rear cover to install memory or communication expansion hardware.
Description
IC754VSI06MTD uses the Intel XScale PXA255 processor and Windows CE.NET to provide a compact operator-interface computer for embedded visualization projects. The architecture gives application developers a familiar Windows environment while retaining the dedicated form factor of the QuickPanel View platform.

Memory resources in IC754VSI06MTD are divided by purpose: DRAM executes the operating system and applications, non-volatile flash retains the operating image and user programs, and battery-backed SRAM provides a separate area for critical retained data.

The flash subsystem in IC754VSI06MTD behaves as a virtual hard drive. A user-accessible Flash Storage area holds long-term application files, while the remaining flash capacity is reserved for the operating system and persistent platform data.

IC754VSI06MTD also includes Windows CE utilities for storage management, system information, file handling, and network access. Its software environment supports custom applications and third-party components alongside the installed QuickPanel visualization runtime.
Alternative Names
IC754 VSI06 MTD IC754-VSI06-MTD IC754VSI06-MTD IC754 VSI06MTD GE IC754VSI06MTD GE Fanuc IC754VSI06MTD General Electric IC754VSI06MTD IC754VSIO6MTD
Technical notes
The IC754VSI06MTD cannot pass through its panel cutout while a CompactFlash card, communication cable, or power plug remains attached.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can touch-point drift be corrected on IC754VSI06MTD?
Open Stylus in the IC754VSI06MTD Control Panel, use the Calibration tab to run Recalibrate, confirm the crosshair sequence, and run Backup so the new calibration survives a power cycle.
Why are Windows CE settings lost after IC754VSI06MTD is powered down?
IC754VSI06MTD stores registry and desktop changes only after the Backup utility is run. Complete Backup after configuration changes and wait for it to finish before removing power.
Can IC754VSI06MTD install a revised Machine Edition project from CompactFlash?
Yes. Insert a CompactFlash card containing a valid updated project into IC754VSI06MTD and reboot; accept the installation prompt, then remove the card after the project is installed.
What should be adjusted when an IC754VSI06MTD application reports insufficient memory?
On IC754VSI06MTD, open System Properties and rebalance the DRAM slider between program and storage memory. Avoid setting either area so low that applications cannot start or files cannot be saved.
Why does HTTP file transfer fail between IC754VSI06MTD and another computer?
The IC754VSI06MTD HTTP utility requires web servers at both endpoints that support the PUT method. Verify that capability and use the documented HTTPUTIL COPY or DELETE syntax.
Why can IC754VSI06MTD Pocket Internet Explorer lose access after changing to a dial-up connection?
If IC754VSI06MTD previously used a fixed Ethernet address, clear that address, disconnect the Ethernet cable, reboot, and reconnect so the dial-up provider can assign the required IP address.
How should IC754VSI06MTD be shut down without losing recent configuration changes?
Close running programs on IC754VSI06MTD, wait for file operations to finish, run Backup for registry and desktop changes, and remove power only after Backup completes.

Product Browsing History