Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can assist with F35 030 11 sourcing, official files, and review of installed HIMatrix channel and network requirements.

F35 030 11

/ 4.9
1001 reviews | Need a Specific Revision?
HIMA F35 030 11 is a compact HIMatrix safety controller combining analog and digital inputs, safety outputs, counters, and Ethernet communication.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for F35 030 11
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for F35 030 11

  • Manufacturer:
    HIMA
  • Part Number:
    F35 030 11
  • Product Family:
    HIMA HIMatrix system
  • Product Type:
    HIMatrix F35 Safety Controller
  • Stock:
    1
  • Digital Inputs:
    24
  • Analog Inputs:
    8
  • Digital Outputs:
    8
  • Counters:
    2 channels; up to 100 kHz
  • Ethernet:
    4 ports
  • Engineering:
    SILworX
  • Operating Temperature:
    0 to 60 °C
  • Protection:
    IP20
  • Estimated shipping dimensions:
    25.7 x 11.4 x 8.3 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals I/O Operation Networking Diagnostics Applications

Features:

  • 24 digital inputs and eight analog inputs
  • Eight safety-related digital outputs
  • Four Ethernet ports and two 100 kHz counters
F35 030 11 places mixed signal acquisition and safety output control in a single compact station.

Local line supervision and event recording help maintenance teams trace field-circuit changes before disturbing the controller hardware.

Selection depends on the required channel mix, safeethernet layout, reaction time, and the SILworX project already approved for the installation.

The HIMA F35 030 11 HIMatrix F35 Safety Controller is available for quotation, official documentation, and configuration support from Apter Power.
HIMA F35 030 11 HIMatrix F35 Safety Controller Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Mixed channels in the compact controller

  • Digital inputs: F35 030 11 provides 24 digital input points for safety contacts, switches, and monitored field states.
  • Analog inputs: Eight analog channels allow the compact controller to acquire continuous process measurements without a separate analog rack.
  • Safety outputs: Eight digital outputs deliver the commanded safe-state actions defined in the SILworX application.
  • Fast counting: Two 100 kHz counter inputs support pulse and frequency-related functions that cannot be handled as ordinary digital signals.
  • Line supervision: Documented line-monitoring functions help distinguish wiring faults from a normal field-state change.

Four-port safety network

  • Ethernet switch: Four integrated 100Base-TX ports let F35 030 11 connect multiple HIMatrix network segments without an external switch at the controller.
  • SafeEthernet: Safety-related data is exchanged with approved HIMA stations through the SafeEthernet protocol.
  • Modbus TCP: Standard Modbus TCP communication can expose selected non-safety data to compatible supervisory equipment.
  • OPC integration: Supported OPC services provide an additional route for process values, alarms, and engineering information.
  • Topology control: Addressing, cycle time, permitted traffic, and physical path separation are validated as part of the safety project.

Channel and communication diagnostics

  • Input supervision: The controller reports configured input and line conditions so a wiring problem can be separated from a process demand.
  • Output feedback: Output diagnostics reveal channel faults that could prevent the commanded de-energized or energized response.
  • Network state: Ethernet and SafeEthernet status information helps identify link, addressing, and peer-communication problems.
  • Event review: Time-related diagnostic records support reconstruction of an operating sequence before the module is reset or replaced.
  • Proof-test boundary: Built-in indications guide troubleshooting but do not replace the proof tests defined for the safety instrumented function.

Projects using F35 030 11

  • Emergency shutdown: Compact ESD stations use the mixed local I/O for shutdown initiators, permissives, and final-element commands.
  • Burner protection: Burner and boiler packages can combine flame-related inputs, sequencing signals, and trip outputs in one controller.
  • Machine safeguarding: Machine projects use the fast counters and safety channels for interlocks, speed-related checks, and emergency stops.
  • Process packages: Skids and distributed process units use F35 030 11 where analog measurement and safety logic must remain close to the equipment.
Description
Combining compact logic processing with mixed field I/O, the HIMA F35 030 11 is a HIMatrix F35 safety controller for localized safety functions. Its F35 03 architecture brings together 24 digital inputs, eight analog inputs, eight digital outputs, two high-speed counters, and four Ethernet interfaces.

Field-circuit supervision in F35 030 11 uses input and output line monitoring, while safeethernet, Modbus, and OPC exchange safety and process information with approved system components. Event recording retains time-stamped operating changes for diagnostic review.

By placing distributed safety logic, network access, and mixed I/O in one compact control-cabinet enclosure, F35 030 11 supports applications that do not require a separate modular rack.
Alternative Names
HIMA F35 030 11 F3503011 F35-030-11 F35 03 0 11 HIMatrix F35 030 11 F35 03011 F35 03 Controller HIMA F3503011
Technical notes
F35 030 11 combines mixed safety I/O, line monitoring, event recording, counters, and Ethernet services in one compact controller.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should mixed field signals be assigned on F35 030 11?
F35 030 11 provides 24 digital inputs, eight analog inputs, and eight digital outputs; allocate channels from the approved safety application and preserve the documented terminal assignments.
Which network services are available on F35 030 11?
F35 030 11 uses four Ethernet ports and supports documented safeethernet, Modbus, and OPC communication within a validated HIMatrix architecture.
How can wiring faults be detected with F35 030 11?
F35 030 11 supports configurable line monitoring on relevant input and output circuits, so open-circuit and short-circuit diagnostics can be incorporated into the safety logic.
Which project records should be reviewed before an F35 030 11 hardware change?
Before replacing F35 030 11, compare the safety project, SILworX version, communication settings, terminal wiring, proof-test requirements, and approved firmware state.
When are the counters on F35 030 11 useful?
The two 100 kHz counters on F35 030 11 can handle documented pulse or frequency signals when the selected input circuitry and safety project support that function.
How should F35 030 11 be installed in a cabinet?
Install F35 030 11 in the documented orientation with adequate ventilation, 24 VDC protection, separation of safety wiring, and access for Ethernet and terminal service.
Which projects suit F35 030 11?
F35 030 11 suits compact emergency-shutdown, burner-management, machine-safety, and process-interlock projects that require mixed local I/O and safety networking.