Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power ensures your legacy Honeywell systems remain mission-critical by providing reliable, verified access to the obsolete MU-TPIX12 module.

MU-TPIX12 51304084-100

/ 4.9
1001 reviews | Need a Specific Revision?
The Honeywell MU-TPIX12 51304084-100 is a 8-channel Pulse Input Field Termination Assembly designed for robust signal acquisition in critical process control environments.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for MU-TPIX12 51304084-100
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MU-TPIX12 51304084-100

  • Manufacturer:
    Honeywell
  • Part Number:
    MU-TPIX12 51304084-100
  • Product Family:
    Honeywell DCS
  • Product Type:
    Pulse Input Field Termination Assembly
  • Stock:
    1
  • Input Channels:
    8 Independent Pulse / Frequency Channels
  • Signal Input Types:
    Sine Wave (Magnetic Pickups), Square Wave (Active Encoders)
  • Rated Supply Voltage:
    24 Vdc (± 10%)
  • Current Consumption:
    136 mA Maximum @ 24 Vdc
  • Terminal Connection Type:
    Screw Compression Terminal Blocks
  • Physical Board Dimension:
    Size B (12-Inch Standard Carrier Slot)
  • Operating Temperature:
    0°C to 60°C (32°F to 140°F)
  • Storage Temperature:
    -40°C to 85°C (-40°F to 185°F)
  • Relative Humidity Limits:
    5% to 95% RH (Non-condensing)
  • Weight:
    0.72 kg
  • Estimated shipping dimensions:
    30.7x12x6.8cm
  • Tariff Code:
    8537109090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Performance & Efficiency Safety & Compliance

Features:

  • High-Fidelity Signal Conditioning & Processing
  • Heavy-Duty Industrial Compression Wiring Interface
  • Native Integration with Legacy HPM Architectures
The Honeywell MU-TPIX12 51304084-100 utilizes dedicated input electronics that stabilize incoming frequencies, suppressing pulse jitter and harmonic distortion. This precise conditioning allows the DCS to execute highly accurate flow totalization and turbine speed metrics, keeping error margins near zero.

Equipped with high-torque compression terminals, the Honeywell MU-TPIX12 51304084-100 maintains long-term structural connection integrity under severe mechanical vibrations. This gas-tight termination method eliminates oxidation-driven contact resistance, preventing intermittent signal failures.

The Honeywell MU-TPIX12 51304084-100 natively fits existing Size B mounting slots, guaranteeing instant communication with TDC 3000 and Experion PKS setups. This plug-and-play profile means engineers can execute live repairs without modifying existing control software or field wiring paths.

The MU-TPIX12 51304084-100 Honeywell Pulse Input Field Termination Assembly may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell MU-TPIX12 51304084-100 Pulse Input Field Termination Assembly Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Honeywell MU-TPIX12 51304084-100 Pulse Input Field Termination Assembly

General

  • Manufacturer Honeywell
  • Model MU-TPIX12 51304084-100
  • Condition New Original ready stock
  • Product Family MU-FOED02 51197564-200,MU-TSDM02 51303932-277,MU-TAOX02 51304476-125
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Mass Flow Integration: Connects directly to high-precision fiscal metering skids to process alternating frequency signals from liquid and gas custody transfer systems.
  • Petrochemical Refining Processing: Translates raw turbine rotations into exact volumetric flow rates within high-velocity oil and gas blending loops.
  • Chemical Batching Control: Monitors low-flow and high-frequency pulse meters to ensure exact stoichiometric ratios during chemical dosing procedures.
  • Water Distribution Overwatches: Monitors continuous pulse counts across large-diameter water transport mains for municipal or heavy industrial utility plants.
  • High-Frequency Thresholds: Capable of reading fast pulse rates with extreme edge-detection accuracy, avoiding pulse-skipping during sudden acceleration.
  • Symmetrical Wave Conditioning: Translates distorted or attenuated field waves into perfectly shaped square waves for reliable digital counter processing.
  • Low Current Draw: Pulls a maximum of 136 mA at 24 Vdc, preventing localized hot-spots inside unventilated control enclosures.
  • Passive Radiative Cooling: Built without cooling fans or active elements, reducing internal failure points and maximizing overall module life expectancy.
  • Class I Division 2 Certified: Approved for deployment inside hazardous zones where flammable gases or volatile vapors may occasionally occur.
  • Failsafe Isolation Barriers: Provides dependable galvanic and opto-isolation vectors to prevent high-voltage field spikes from tracking back into control rooms.
  • Extended Storage Boundaries: Operates flawlessly up to 60°C and withstands prolonged storage down to -40°C without component degradation.
  • Non-Condensing Humidity Shielding: Designed with high-performance tracking distances on the PCB to prevent surface tracking in damp 95% RH field conditions.
Description
The Honeywell MU-TPIX12 51304084-100 acts as the critical physical and electrical interface between field-mounted pulse-generating devices and the High-Performance Process Manager (HPM) subsystem. By accepting high-frequency inputs from turbine meters, magnetic pickups, tachometers, and optical encoders, this termination assembly ensures that raw field data is cleanly routed to the processing layer. Its advanced hardware layout is explicitly optimized to eliminate signal degradation, ensuring absolute data fidelity for heavy industrial automation.

Built to withstand severe operational environments, the Honeywell MU-TPIX12 51304084-100 features robust compression-type terminal blocks that ensure gastight, vibration-resistant wiring connections. This mechanical reliability drastically lowers the risks of intermittent open circuits caused by structural harmonics, which are common in petrochemical and power generation facilities. Additionally, the board's embedded passive filtering circuitry mitigates the impact of electromagnetic interference (EMI) and radio frequency interference (RFI) before the signal reaches the controller.

To maximize facility uptime, the Honeywell MU-TPIX12 51304084-100 incorporates specialized per-channel isolation and integrated loop topology features that facilitate seamless pass-through diagnostics. When paired with the appropriate Pulse Input Input/Output Processor (IOP), it allows plant engineers to swiftly trace electrical faults or sensor failures without disrupting adjacent control loops. This targeted troubleshooting capability shortens Mean Time to Repair (MTTR) and protects complex process lines from unplanned shutdowns.

As a crucial lifecycle extension component, the Honeywell MU-TPIX12 51304084-100 mounts seamlessly into standard Size B HPM cabinet layouts, allowing for effortless hot-swapping or drop-in replacements during routine turnaround turnarounds. This compatibility allows plant operators to sustain or expand their legacy automation infrastructure without committing to capital-intensive, full-scale system migrations. It represents a highly cost-effective path to maintaining superior operational efficiency and strict loop regulation across long-term asset lifecycles.
Alternative Names
MU-TPIX12 51304084-100 MU-TP1X12 51304084-100 MU-TPIX2 5I304084-I00 MU-TPIX12 513O4O84-1OO MU-TAOX02 51304476-125 MU-FOED02 51197564-200 MU-TSDM02 51303932-277
Technical notes
The Honeywell MU-TPIX12 51304084-100 is specifically designed for integration with High-Performance Process Manager (HPM) assemblies, requiring strict adherence to the specified 24 Vdc power distribution requirements. Engineers must ensure that the Honeywell MU-TPIX12 51304084-100 is correctly mounted in Size B enclosures and configured for the specific pulse signal characteristics (sinusoidal or square wave) of the connected field devices to prevent counting errors.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What specific field signal types can the HONEYWELL MU-TPIX12 51304084-100 accept, and how is the signal type selected?
The HONEYWELL MU-TPIX12 51304084-100 accepts both low-level sinusoidal waves (such as those from passive magnetic pickups) and active square-wave pulses (from powered encoders or proximity switches). Signal selection is accomplished via physical hardware jumpers located on the board surface, which alter the amplification gain and trigger thresholds to match the specific electrical characteristics of your field instrument.
How does the wiring topography of the HONEYWELL MU-TPIX12 51304084-100 connect to the primary DCS controller hardware?
The HONEYWELL MU-TPIX12 51304084-100 connects to the main High-Performance Process Manager (HPM) cabinet architecture using standard multi-conductor field interface cables. Field instrumentation wires land directly on its 8-channel compression terminals, while the conditioned pulse trains are routed via a dedicated connector to the corresponding Pulse Input Input/Output Processor (IOP) card, such as the MU-PPIX02 module.
Can the HONEYWELL MU-TPIX12 51304084-100 pass granular loop diagnostic data back to Experion PKS software architectures?
While the HONEYWELL MU-TPIX12 51304084-100 is a passive termination assembly, it fully supports the pass-through monitoring protocols managed by the upstream IOP. It permits the control system to detect open-circuit field wiring, power losses, and out-of-range input frequencies, surfacing clear system alerts within the Experion PKS or TDC 3000 operator environment.
Is it possible to configure a redundant hot-backup circuit utilizing the HONEYWELL MU-TPIX12 51304084-100 assembly?
No, the HONEYWELL MU-TPIX12 51304084-100 is strictly designed for non-redundant, simplex configurations where 8 channels map to a single pulse processor. For loops requiring critical dual-redundancy paths, alternative Honeywell High-Level or specialized redundant FTA architectures must be specified in the system drawings.
Under what environmental and temperature limitations can the HONEYWELL MU-TPIX12 51304084-100 be safely operated?
The HONEYWELL MU-TPIX12 51304084-100 is certified to run within an operating temperature envelope of 0°C to 60°C (32°F to 140°F) with a non-condensing relative humidity range of 5% to 95%. If the module is deployed in corrosive atmospheres or outdoors, it must be housed inside an environmentally sealed, climate-controlled Type 4X or IP66 enclosure.