/ 4.9
1001 reviews | Need a Specific Revision?
The Honeywell EX‑DGM506 is an industrial‑grade explosion‑protected gas pressure monitor designed for reliable gas overpressure detection in hazardous environments where flammable gases are present.
Get a quick price for EX-DGM506
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for EX-DGM506

  • Manufacturer:
    Honeywell
  • Part Number:
    EX-DGM506
  • Product Family:
    Honeywell DCS
  • Accuracy:
    1 %
  • Port Size:
    G 1/2, G 1/4
  • Mounting Style:
    Panel Mount
  • Operating Supply Voltage:
    250 VAC
  • Maximum Operating Temperature:
    + 60 C°
  • Minimum Operating Temperature:
    - 20 C°
  • Operating Supply Current:
    3 A
  • Weight:
    0.38 kg
  • Estimated shipping dimensions:
    12.2x10.7x3cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications
 

Features:

  • Interface Between the Gas Supply System and Burner Control Unit
  • Combines Capability of Gas Pressure Monitoring with ATEX Certified Safety Shutdown
  • Operates in Conjunction with the EX-DGM Series and Standard Honeywell Burner Management Systems
The EX-DGM506 operates as the ATEX Certified Gas Pressure Monitor in a burner management system, providing reliable gas pressure monitoring and safety shutdown for gas-fired equipment within the system. It continuously converts incoming gas pressure signals (15-60 mbar) to regulated electrical switch outputs and distributes this safety status through the control circuit to support steady state operation of all burner control and flame safeguard functions. Seamless pressure monitoring is standard with the EX-DGM506, however using an optional Service Function Configuration will provide additional diagnostic capabilities and maintenance flexibility in demanding industrial environments. The EX-DGM506 has made improvements in several areas over previous gas pressure switch designs in addition to incorporating universal 15-60 mbar pressure range capability with DIN EN 1854 and ATEX 2014/34/EU certification within the Honeywell FEMA product family.

The EX-DGM506 provides essential gas pressure monitoring functions common to the entire burner control system, and is a critical component of the safety interlock path, directly affecting the proper, normal operation of the overall combustion system. One EX-DGM506 pressure monitor is required per gas supply line depending on the desired safety integrity level and system configuration. The EX-DGM506 occupies a dedicated mounting position on the gas train and is always located upstream of the main gas valve (the dedicated pressure monitoring point, the primary safety shutdown interface).

For Dual Redundant Gas Pressure Monitoring applications, the Burner Management System requires a second EX-DGM506 pressure monitor installed in the redundant gas supply line. In addition to standard single monitor operation, the redundant configuration also performs automatic cross-verification for critical combustion safety applications. The dual pressure monitor configuration executes comparison using the internal safety logic specified in the burner control options. Using this method, the redundant gas pressure system continually monitors the health of both pressure channels. If the system detects that the primary EX-DGM506 is no longer providing stable pressure indication (outside configured 15-60 mbar/tolerance levels), it will automatically initiate safety shutdown and place an event in the Burner Management System Fault Log.

The EX-DGM506 Rated Gas Pressure Monitor may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
 
Honeywell EX-DGM506 ATEX Certified Gas Pressure Monitor Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
 Honeywell EX-DGM506 ATEX Certified Gas Pressure Monitor Specs

General

  • Manufacturer Honeywell
  • Model EX-DGM506
  • Condition New Original ready stock
  • Product Family EX-DGM506-S,EX-DGM516,EX-DGM516-S
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Description
It is part of Honeywell’s Ex‑DGM series of pressure monitors and is specifically calibrated for rising pressure, making it suitable for safety‑critical applications such as gas burner controls, fuel gas systems, and combustion equipment in industrial facilities.

Built to meet stringent safety and performance standards, the EX‑DGM506 features ATEX and IECEx explosion protection ratings, robust die‑cast aluminum housing with IP65 ingress protection, and rugged stainless‑steel sensor materials that deliver dependable operation even in harsh environments with wide temperature variations. It monitors relative overpressure and provides a fixed differential switching response within the specified operating range.

The pressure monitor supports both G1/4" internal and G1/2" external pressure connections, and its electrical interface includes a terminal connection suitable for integration into control panels or safety systems. 

With a pressure adjustment range of 15–60 mbar, a switching differential of approximately 7–11 mbar, and a maximum pressure rating of up to 5 bar, the EX‑DGM506 delivers accurate, repeatable gas pressure monitoring essential for protecting industrial gas systems and ensuring operational safety.

Alternative Names
EX-DGM506-S EX-DGM516 EX-DGM516-S
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the operating pressure range of the EX-DGM506?
The EX-DGM506 is designed to monitor low-pressure gas systems with an adjustable pressure range of 15–60 mbar, providing precise overpressure detection.
What type of environment is the EX-DGM506 suitable for?
It is certified for explosion‑proof operation (ATEX and IECEx), making it suitable for hazardous areas with flammable gases.
What connections and electrical ratings does the EX-DGM506 support?
The device features G1/4" internal and G1/2" external pressure ports, an IP65 protection rating, and supports both AC and DC switching loads, enabling flexible integration into industrial gas monitoring and safety systems.