Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    For FC-DO-1624 requirements, Apter Power can provide current pricing and sourcing assistance for the required quantity and delivery schedule.

FC-DO-1624

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell FC-DO-1624 is a 16-channel 24 v dc digital output module for high-density DC field-device switching.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for FC-DO-1624
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FC-DO-1624

  • Manufacturer:
    Honeywell
  • Part Number:
    FC-DO-1624
  • Product Family:
    Honeywell FSC Series
  • Product Type:
    16-Channel 24 V DC Digital Output Module
  • Stock:
    1
  • Construction:
    Conformal-coated FC construction
  • Channel capacity:
    16 digital output channels
  • Signal or power data:
    24 V DC field loads
  • Matched hardware:
    Safety Manager non-safe I/O rack
  • Application:
    high-density DC field-device switching
  • Diagnostic focus:
    field supply, load grouping and short circuits
  • Installation checks:
    Power, grounding, terminal allocation and end-to-end functional test
  • Compatibility basis:
    Exact model, hardware revision, firmware and approved project configuration
  • Tariff Code:
    85389000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Signal Data Diagnostics Compatibility Installation Check

Features:

  • 16 digital output channels
  • 24 v dc field loads
  • Matched with Safety Manager non-safe I/O rack
FC-DO-1624 provides high-density DC field-device switching in a Honeywell Safety Manager installation.

Its conformal-coated fc construction and the documented 24 V DC field loads must match the cabinet and field design.

Verify field supply, load grouping and short circuits and the complete connected path before the equipment is released to operation.

The Honeywell FC-DO-1624 16-Channel 24 V DC Digital Output Module is available for quotation and technical support from Apter Power.
Verified resources for FC-DO-1624:

Signal Data:

  • 16 digital output channels
  • 24 V DC field loads
  • System role: high-density DC field-device switching
Use the documented FC-DO-1624 electrical limits when calculating the complete connected circuit.

Diagnostics:

  • Field supply, load grouping and short circuits
  • Check channel and system alarms
  • Document normal and fault-state results
Resolve all FC-DO-1624 wiring, power, communication and system diagnostics before release to operation.

Compatibility:

  • Matched hardware: Safety Manager non-safe I/O rack
  • Construction: Conformal-coated FC construction
  • Confirm firmware and hardware revision
Match FC-DO-1624 to the approved cabinet, cable, termination and field-device arrangement.

Installation Check:

  • Verify power, polarity and grounding
  • Confirm terminal allocation and cable identification
  • Prove the complete end-to-end function
Record the final configuration and all functional-test results after installing FC-DO-1624.
Description
Honeywell FC-DO-1624 16-Channel 24 V DC Digital Output Module is designed for high-density DC field-device switching within the Honeywell Safety Manager platform. Its documented configuration uses 16 digital output channels and 24 V DC field loads.

The FC-DO-1624 must be matched with Safety Manager non-safe I/O rack and the approved cabinet, cable, termination and firmware arrangement. The conformal-coated fc construction must also agree with the environmental qualification and the installed project hardware.

Before commissioning FC-DO-1624, verify field supply, load grouping and short circuits, terminal allocation, power and grounding, then prove the complete field path from the connected device to the control application. Record the hardware revision and all as-left test results.
Alternative Names
FC-DO-1624 FC DO 1624 FCDO1624 Honeywell FC-DO-1624 Honeywell FC DO 1624 Honeywell FCDO1624 FC-DO-1624 16-Channel 24 V DC Digital Output Module Honeywell Safety Manager FC-DO-1624
Technical notes
FC-DO-1624 is the conformal-coated fc construction 16-channel 24 v dc digital output module for high-density DC field-device switching. Verify field supply, load grouping and short circuits and the matched system hardware before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What field signal or power arrangement is documented for FC-DO-1624?
FC-DO-1624 is documented for 24 V DC field loads; verify the actual field circuit and site limits before connection.
How much channel or system capacity does FC-DO-1624 provide?
The documented capacity is 16 digital output channels. Channel allocation must match the project drawings and application database.
Which hardware should be paired with FC-DO-1624?
Use Safety Manager non-safe I/O rack and confirm connector, cable, firmware and chassis compatibility against the installed system.
Which diagnostics should be checked on FC-DO-1624?
Review field supply, load grouping and short circuits, clear unexplained alarms and prove each affected signal or power path.
What commissioning test is required for FC-DO-1624?
Check power and grounding, verify terminal allocation, simulate normal and fault states, and record the application response.
Can a different FS, FC or related construction replace FC-DO-1624?
Only after the conformal-coated fc construction, hardware revision, environmental qualification and project approval are confirmed.
What must be reviewed before replacing FC-DO-1624?
Compare the exact nameplate, Safety Manager non-safe I/O rack, cabinet layout, firmware release, field wiring and safety validation requirements.
What information is needed to quote FC-DO-1624?
Provide the full model, nameplate revision, connected hardware, signal or load details, required construction, quantity and destination.

Product Browsing History