Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    SP-MRUN01 remains documented as the per-meter-run license for ControlEdge RTU electronic flow-metering applications.

SP-MRUN01

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell SP-MRUN01 is a controledge rtu meter run license for the ControlEdge engineering environment.
In Stock
Ships by Sunday, November 1
Fast Shipping Available
Get a quick price for SP-MRUN01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SP-MRUN01

  • Manufacturer:
    Honeywell
  • Part Number:
    SP-MRUN01
  • Product Family:
    Honeywell FSC Series
  • Product Type:
    ControlEdge RTU Meter Run License
  • Stock:
    1
  • License basis:
    One license per meter run per RTU
  • Metering function:
    Electronic flow metering for gas and liquid
  • Non-redundant capacity:
    Maximum 4 meter runs
  • Redundant capacity:
    Maximum 12 meter runs
  • Data-log protocols:
    Enron Modbus responder and DNP3
  • Gas metering reference:
    API MPMS 21.1
  • Liquid metering reference:
    API MPMS 21.2
  • Regulatory reference:
    AER Directive 17
  • Tariff Code:
    85234920
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals License Data Compatibility Deployment Installation Check
Product overview:
  • One controller-resident license for each meter run
  • Gas and liquid electronic flow metering
  • Four non-redundant or twelve redundant meter runs maximum
Honeywell SP-MRUN01 licenses one electronic flow-metering run on one ControlEdge RTU. The entitlement is allocated per meter run, so an RTU configured with four runs requires four SP-MRUN01 licenses.

ControlEdge RTU supports gas and liquid metering together, with documented limits of four runs on a non-redundant controller and twelve runs on a redundant controller. Logged metering data can be exposed through Enron Modbus responder or DNP3 according to the engineered system design.

Before ordering SP-MRUN01, confirm the exact number of runs, controller redundancy, measurement standard and data-retrieval protocol. Each run should be validated against its transducers, calculation method, archive interval and custody-transfer procedure before service.
Verified resources for SP-MRUN01:
License Data:
  • Allocation: one license per run per RTU
  • Non-redundant limit: four runs
  • Redundant limit: twelve runs
Use the documented SP-MRUN01 entitlement or release data when planning the engineering environment.
Compatibility:
  • Match the license count to configured runs
  • Confirm controller redundancy and firmware
  • Select the required metering standard
Compatibility for SP-MRUN01 depends on the exact software release, controller firmware and validated project revision.
Deployment:
  • Allocate a license to each run
  • Configure metering and archive parameters
  • Map Enron Modbus or DNP3 access
Deploy SP-MRUN01 under controlled engineering access and retain the installation and entitlement records.
Installation Check:
  • Count licensed and configured runs
  • Validate live and calculated values
  • Test log retrieval and time stamping
Complete release, project and communication checks before SP-MRUN01 is used on a production system.
Description
SP-MRUN01 ControlEdge RTU Meter Run License licenses one electronic flow-metering run on one ControlEdge RTU. The entitlement is allocated per meter run, so an RTU configured with four runs requires four SP-MRUN01 licenses.

ControlEdge RTU supports gas and liquid metering together, with documented limits of four runs on a non-redundant controller and twelve runs on a redundant controller. Logged metering data can be exposed through Enron Modbus responder or DNP3 according to the engineered system design.

Before ordering SP-MRUN01, confirm the exact number of runs, controller redundancy, measurement standard and data-retrieval protocol. Each run should be validated against its transducers, calculation method, archive interval and custody-transfer procedure before service.
Alternative Names
SP-MRUN01 SP MRUN01 SPMRUN01 Honeywell SP-MRUN01 Honeywell SP MRUN01 Honeywell SPMRUN01 ControlEdge SP-MRUN01 SP-MRUN01 ControlEdge RTU Meter Run License
Technical notes
SP-MRUN01 is allocated once for each meter run configured on a ControlEdge RTU. Check the run count, redundancy architecture and metering standard before licensing and commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many SP-MRUN01 licenses are required?
Allocate one license for every meter run configured on each RTU.
What is the non-redundant meter-run limit?
A non-redundant ControlEdge RTU supports a maximum of four meter runs.
What is the redundant meter-run limit?
A redundant ControlEdge RTU supports a maximum of twelve meter runs.
Can gas and liquid runs operate together?
Yes. Honeywell documents that gas and liquid meter runs can execute together.
How can metering logs be retrieved?
The documented interfaces include Enron Modbus responder over serial or Ethernet and DNP3 over Ethernet.
Which metering standards are referenced?
The specification references API MPMS 21.1 for gas, API MPMS 21.2 for liquid and AER Directive 17.
What must be tested before commissioning a run?
Validate transducer inputs, calculation settings, archive intervals, time synchronization and log retrieval.
What information is needed to quote SP-MRUN01?
Provide the run count, controller redundancy, standards, firmware release, quantity and destination.

Product Browsing History