Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

T8013

/ 4.9
1001 reviews | Need a Specific Revision?
The ICS TRIPLEX T8013 is a Sequence Of Events (SOE) and Process Historian (PH) collector software package designed to log, record, and review critical system data from Trusted systems.
Get a quick price for T8013
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for T8013

  • Manufacturer:
    ICS Triplex
  • Part Number:
    T8013
  • Product Family:
    (TMR) Processor
  • Product Type:
    SOE & Process Historian Collector Package
  • Timestamp Resolution:
    True 1 ms
  • Scan Time Dependency:
    Resolution maintained regardless of program (application) scan time
  • Log Capacity (Communications Interface):
    4,000 entries (scrolling buffer)
  • Log Capacity (Processor):
    1,000 most recent entries
  • Data Overwrite Behavior:
    Old data overwritten after 4,000 entries in communications module
  • Data Loss Prevention:
    No data loss if collector remains connected and actively gathering
  • Required Hardware:
    Communications interface module
  • Distribution Medium:
    Supplied on a single disk
  • Weight:
    0.05 kg
  • Estimated shipping dimensions:
    14.2 cm x 12.5 cm x 1.0 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Communication & Connectivity Environmental Ratings

Features:

  • Serves as the Data Acquisition Link Between the Trusted Controller Communications Interface and Engineering Workstation
  • Unifies Discrete Sequence Of Events Timestamping with Analog Process Historian Variable Recording
  • Coordinates with Trusted I/O Modules and System Processor Architecture for Millisecond-Resolution Data Capture
The T8013 operates as the Sequence Of Events & Process Historian Collector Package in a Trusted system environment, generating time-stamped logs of all discrete state changes and recording analog variables for comprehensive operational monitoring. It continuously collects data from the controller via the communications interface module, utilizing either the serial or Ethernet ports on the rear panel to establish the data transmission pathway (the front serial port cannot be used for this purpose). Seamless data acquisition is standard with the T8013, and initiating multiple SOE and PH displays will enable concurrent gathering of information from multiple Trusted systems without interruption. The T8013 achieves true 1ms timestamp resolution directly from the I/O modules regardless of application scan time, representing a significant advancement in temporal accuracy over conventional processor-dependent logging methods.

The T8013 provides essential data collection functions critical to the entire Trusted system monitoring architecture, and is a vital component of the analytical pathway, directly supporting accurate incident reconstruction and proper operational review of the overall control system. One T8013 disk is required per installation, with the software package operating from the engineering workstation rather than occupying physical rack slots. The T8013 is always deployed in conjunction with the Trusted communications interface module, which manages the 4,000-entry log buffer while the processor retains the most recent 1,000 entries.

For concurrent multi-system monitoring applications, the Trusted system architecture supports multiple T8013 SOE and PH displays initiated from the engineering workstation. In addition to standard single-system data collection, this multi-display configuration also performs simultaneous gathering of discrete events and analog variables from several Trusted controllers. The T8013 collection mechanism executes data acquisition using the true 1ms timestamping resolution provided by the Trusted I/O module internal circuitry. Using this method, the system continually monitors and logs all discrete changes of state—such as faults, field trips, and output actions—and analog process variables. If the communications interface module detects that the log has reached its 4,000-entry capacity, it will automatically overwrite older data in the scrolling buffer while the processor maintains the most recent 1,000 entries, ensuring no data loss occurs provided the T8013 collector remains connected and actively gathering.

The T8013 ICS TRIPLEX SOE & Process Historian Collector Package may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS TRIPLEX T8013 SOE & Process Historian Collector Package Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ICS TRIPLEX T8013 SOE & Process Historian Collector Package Specs

General

  • Manufacturer ICS TRIPLEX
  • Model T8013
  • Condition New Original ready stock
  • Product Family T8015,T8017,T8019
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Sequence of Events (SOE) Logging: Generates millisecond-accurate, time-stamped logs of all system faults, safety trips, interlocks, and digital output actions.
  • Trip & Root-Cause Analysis: Reconstructs precise timelines leading up to emergency plant shutdowns (ESD) to diagnose the triggering event.
  • Process Variable Archiving: Uses the Process Historian component to continually log and trend continuous analogue variables like pressure, temperature, and flow.
  • System Diagnostic Monitoring: Archives internal safety controller hardware statuses and diagnostic indicators for predictive maintenance.
  • Regulatory Compliance Reporting: Acts as an unalterable, long-term historical database to satisfy industrial safety compliance audits.
  • Interface Hardware: Connects directly with modules like the Trusted Communications Interface (T8151B/C) or the Trusted Gateway Module (T8170).
  • Network Connectivity: Uses standard Dual Ethernet (10/100BaseT) pathways over TCP/IP networks to extract collected data buffers from the controller.
  • Industrial Protocols: Utilizes native Modbus Master/Slave protocols and specialized Sequence of Events over Modbus extensions to handle massive high-speed event streams.
  • Data Integration: Feeds collected historical data into standard desktop and enterprise environments through integrated IEC 61131 Toolset dictionaries and standard Windows data export tools (e.g., Clipboard, text file generation, and direct Excel pasting).
  • Host Platform: Typically deployed on industrial-grade servers or Engineering Workstations (EWS) installed in climate-controlled control rooms.
  • Controller-Side Resilience: The field data it collects relies on the underlying Trusted TMR Controller, which is rated for industrial deployment across a standard operating temperature of -10°C to 50°C and non-condensing relative humidity ranges.
  • Interference Tolerances: Requires network architecture designed to resist Radio Frequency Interference (RFI) to prevent packet drops during high-density emergency event burst collection.
Description
The ICS TRIPLEX T8013, designated as the Sequence Of Events & Process Historian Collector Package (SOE & Process Historian), is specifically engineered to address the critical requirement for high-fidelity event logging and historical analog data recording within industrial Trusted control systems. This T8013 software package solves the fundamental challenge of capturing discrete state changes—such as faults, field trips, and output actions—alongside continuous analog process variables, enabling precise post-event analysis and operational accountability through reliable, time-stamped data collection.

The T8013 package delivers two core programs on a single disk. The Sequence Of Events (SOE) collector generates a comprehensive, time-stamped log of all discrete changes of state recorded by the system, encompassing faults, field trips, and output actions. Complementing this, the Process Historian (PH) program provides dedicated facilities to log and record analog variables. A defining technical characteristic of the T8013 is that timestamps originate directly from the I/O modules rather than the main processor, achieving true 1ms resolution independent of application scan time. The system architecture supports concurrent operation of multiple SOE and PH displays, enabling simultaneous data gathering from multiple Trusted systems. Log data operates on a scrolling basis with a capacity of up to 4,000 entries maintained within the communications interface module, while the processor retains the most recent 1,000 entries, ensuring no data loss occurs provided the collector remains connected and actively gathering within these defined capacity boundaries.

The T8013 is applied within industrial control environments employing Trusted system platforms, where precise reconstruction of discrete events and historical trending of analog variables are required for operational integrity and analytical review. Primary application scenarios include system fault diagnosis requiring millisecond-accurate event sequencing, documentation of safety-related state changes for compliance and audit purposes, post-incident analytical review of field trips and controller output actions, and continuous process variable monitoring deployed across single or multiple interconnected Trusted control systems.
Alternative Names
T8013 T8O13 T80I3 T8OI3 T8017 T8019
Technical notes
The T8013 package provides two primary functionalities supplied on a single disk: the SOE collector program and the PH program. The SOE collector program generates a highly accurate, time-stamped log of all discrete changes of state recorded by the system, such as system faults, field trips, and output actions. Simultaneously, the PH program provides the necessary facility to log and record analog variables.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does the T8013 achieve accurate event recording?
A major advantage of the T8013 package is that time stamps are generated directly by the I/O modules instead of the main processor. This architecture provides true 1-millisecond resolution and ensures that event accuracy is not affected by application scan times.
How do users operate the T8013 software?
After launching the software, users access a dedicated dialog interface that allows them to open either the SOE window or the PH log. The software also supports multiple simultaneous displays, enabling operators to collect and monitor data from several Trusted systems at the same time.
What industrial problem does the T8013 solve?
The T8013 package addresses the challenge of precise event tracking and analog data logging in safety-critical environments. It helps prevent data loss and eliminates inaccuracies in millisecond-level event recording during complex industrial incidents.
How does the T8013 prevent data loss?
The software uses a scrolling log architecture. The main processor stores the latest 1,000 entries, while the communications interface module can retain up to 4,000 entries before older records are overwritten. When the T8013 collector remains actively connected, data can be gathered continuously within this hardware limit.

Product Browsing History