Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power can provide 341-702-100 1DXC 03 for intron-d exchange control board replacement and installed-system maintenance; confirm the complete configuration and delivery requirements before ordering.

341-702-100 1DXC 03

/ 4.9
1001 reviews | Need a Specific Revision?
341-702-100 1DXC 03 is a INDUSTRONIC INTRON-D Exchange Control Board for intron-d exchange control board replacement and installed-system maintenance.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for 341-702-100 1DXC 03
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 341-702-100 1DXC 03

  • Manufacturer:
    INDUSTRONIC
  • Part Number:
    341-702-100 1DXC 03
  • Product Family:
    INDUSTRONIC
  • Product Type:
    INTRON-D Exchange Control Board
  • Stock:
    1
  • Hardware function:
    INTRON-D Exchange Control Board
  • Control platform:
    GE Mark VI / Mark VIe control
  • Interface scope:
    Board- or module-specific interfaces for the GE Mark VI / Mark VIe control installation
  • Primary application:
    INTRON-D Exchange Control Board replacement and installed-system maintenance
  • Hardware identity:
    341-702-100 1DXC 03
  • Replacement basis:
    Exact hardware and installed configuration match
  • Commissioning checks:
    Power, grounding, wiring, diagnostics and channel response
  • Documentation basis:
    OEM-authored family reference plus installed nameplate
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Hardware Data Compatibility Commissioning Installation Check

Product overview:

  • INTRON-D Exchange Control Board
  • GE Mark VI / Mark VIe control
  • INTRON-D Exchange Control Board replacement and installed-system maintenance

341-702-100 1DXC 03 provides board- or module-specific interfaces for the ge mark vi / mark vie control installation.

Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.

Apter Power can provide 341-702-100 1DXC 03 for quotation and technical review.

Hardware data:

  • Exact identity: 341-702-100 1DXC 03
  • Function: INTRON-D Exchange Control Board
  • Platform: GE Mark VI / Mark VIe control

Board- or module-specific interfaces for the GE Mark VI / Mark VIe control installation

Compatibility review:

  • Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
  • Compare connectors, terminal assignments and configured options
  • Use an engineered migration when revisions are not interchangeable

341-702-100 1DXC 03 should be matched to the complete installed control assembly.

Commissioning checks:

  • Verify power and protective isolation
  • Confirm grounding, shielding and field wiring
  • Test diagnostics and functional response

Record baseline results for 341-702-100 1DXC 03 before returning the machine to service.

Installation check:

  • Photograph the original hardware and settings
  • Follow site lockout/tagout and ESD controls
  • Inspect connectors, torque and ventilation

Do not energize 341-702-100 1DXC 03 until wiring and configuration reviews are complete.

Description

341-702-100 1DXC 03 is a INDUSTRONIC INTRON-D Exchange Control Board associated with the GE Mark VI / Mark VIe control platform. Its documented role is intron-d exchange control board replacement and installed-system maintenance, with board- or module-specific interfaces for the ge mark vi / mark vie control installation.

341-702-100 1DXC 03 must be treated as one complete hardware and configuration reference. The board or module, terminal arrangement, firmware and connected control hardware must match the installed cabinet drawings; a similar family code does not establish electrical or functional interchangeability.

Before installing 341-702-100 1DXC 03, isolate power, photograph the existing nameplate and connectors, record rack position and jumper settings, compare terminal assignments, and verify power, grounding, field wiring and diagnostics during commissioning.

Alternative Names
341-702-100 1DXC 03 3417021001DXC03 341 702 100 1DXC 03 INDUSTRONIC 341-702-100 1DXC 03 341-702-100 1DXC 03 INTRON-D Exchange Control Board 341-702-100 1DXC 03 replacement module 341-702-100 1DXC 03 spare part 341-702-100 1DXC 03 datasheet
Technical notes
341-702-100 1DXC 03 is the exact intron-d exchange control board reference for the GE Mark VI / Mark VIe control installation. Confirm the exact nameplate, hardware revision, firmware, rack or cabinet position, terminal assignments and connected equipment.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which installed details must match before replacing 341-702-100 1DXC 03?
Match the complete 341-702-100 1DXC 03 nameplate, hardware revision, firmware, rack or cabinet position, connectors and terminal assignments.
How should the interface for 341-702-100 1DXC 03 be verified?
Use the system drawings to verify board- or module-specific interfaces for the ge mark vi / mark vie control installation, including signal type, polarity, reference potential and grounding.
What should be checked before applying power to 341-702-100 1DXC 03?
Confirm supply voltage, protective devices, connector keying, jumper positions, field isolation and cabinet grounding before energizing.
How is 341-702-100 1DXC 03 commissioned after installation?
Check the intron-d exchange control board replacement and installed-system maintenance function channel by channel and compare diagnostics, feedback and commanded states with the original configuration.
Can a similar family board replace 341-702-100 1DXC 03?
Not by part-family similarity alone. Electrical interfaces, firmware, revision, options and configured function must be reviewed as one replacement package.
What manual should be used for 341-702-100 1DXC 03?
Use the product-specific Apter Power datasheet together with the latest applicable OEM system manual and the installed cabinet drawings.
What information is needed for a quotation for 341-702-100 1DXC 03?
Provide clear front and rear nameplate photos, complete suffixes, quantity, installed platform, failure symptoms and delivery destination.
How should a stored spare for 341-702-100 1DXC 03 be evaluated?
Inspect packaging and connectors, review storage history, verify firmware and revision, and perform controlled bench or cabinet tests before return to service.