9753-110

/ 4.9
1001 reviews | Need a Specific Revision?
Invensys TRICONEX 9753-110 is a 16-point external termination panel for compatible Tricon pulse-input, pulse-totalizer, and analog-voltage-input modules.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 9753-110
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 9753-110

  • Manufacturer:
    Invensys
  • Part Number:
    9753-110
  • Product Family:
    Triconex
  • Product Type:
    Pulse / pulse-totalizer / analog-voltage input external termination panel
  • Stock:
    1
  • Panel type:
    Basic external termination panel
  • Pulse input capacity:
    8 points with 3510 or 3511
  • Pulse-totalizer capacity:
    16 points with 3515; two panels per 32-point module
  • Analog voltage input capacity:
    16 points; supported ranges depend on the connected module
  • Compatible modules:
    3510, 3511, 3515, 3700, 3700A, 3701, 3703E, 3721
  • Interface cable:
    4000103-510
  • ETA part number:
    3000400-510
  • Dimensions:
    7.62 × 10.795 × 12.7 cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Module Matching Pulse Wiring Installation Application
  • Supports selected Tricon pulse-input, pulse-totalizer, and analog-voltage-input modules
  • Provides 16 field points, with function and usable count determined by the connected module
  • Uses documented cable 4000103-510 and interface assembly 3000400-510

The Invensys TRICONEX 9753-110 is a basic external termination panel that brings selected Tricon input-module signals to field screw terminals.

Its role changes with the connected module: eight pulse-input points with 3510 or 3511, sixteen pulse-totalizer points with 3515, or sixteen analog-voltage-input points with supported 3700-series modules.

Confirm the installed I/O module, signal type, panel count, point labels, sensor output, shielding, unused-point treatment, interface cable, and approved drawing before reconnecting field conductors.

Availability, condition, price, and shipping time for Invensys TRICONEX 9753-110 are confirmed during quotation.

Invensys TRICONEX 9753-110 External Termination Panel Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Use 3510 or 3511 for the documented eight-point pulse-input arrangement
  • Use two panels for all thirty-two points of a 3515 pulse-totalizer module
  • Match analog-voltage service to 3700, 3700A, 3701, 3703E, or 3721 requirements
  • Use a compatible push-pull sensor output for 3515 pulse-totalizer service
  • Use individually shielded twisted pairs for runs longer than 15 m
  • Apply the documented unused-point shorting and termination-resistor practices
  • Confirm the 1–16 and 17–32 labels before landing field conductors
  • Verify interface cable 4000103-510 and ETA 3000400-510 against the installed hardware
  • Keep shield grounding and signal returns consistent with the approved loop drawing
  • Turbine and rotating-equipment speed or pulse monitoring
  • Flow, batch, and event totalization using compatible pulse sensors
  • Tricon analog-voltage input termination for supervised process signals
Description
The Invensys TRICONEX 9753-110 is a basic 16-point external termination panel for selected Tricon pulse-input, pulse-totalizer-input, and analog-voltage-input modules. It provides the field screw terminals and interface-cable connection required to route signals to the I/O module.

For pulse inputs, TRICONEX 9753-110 supports eight points with 3510 or 3511. For pulse-totalizer service, it supports sixteen points with 3515 and requires two panels for the module's 32 points. It can also terminate voltage inputs for 3700, 3700A, 3701, 3703E, and 3721.

Selection must follow the installed module and application. Confirm point labels, the interface cable, unused-point treatment, sensor output type, shield practice, and any termination-resistor requirement before reconnecting field wiring.
Alternative Names
TRICONEX 9753-110 Triconex 9753-110 Invensys TRICONEX 9753-110 Invensys Triconex 9753-110 9753 110
Technical notes
TRICONEX 9753-110 supports distinct pulse, totalizer, and voltage-input uses; confirm the connected module, point labels, cable, unused-point treatment, and sensor wiring.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can a buyer confirm whether TRICONEX 9753-110 is being used for pulse counting or analog-voltage input?
Identify the connected Tricon I/O module and the field-device signal. TRICONEX 9753-110 is a shared termination platform; the installed module, not the panel alone, determines whether the circuit is pulse input, pulse totalizer, or analog voltage.
Does an order for TRICONEX 9753-110 automatically include the interface cable and interface assembly?
Do not assume so. The manufacturer cross-reference identifies cable 4000103-510 and ETA 3000400-510, but the quotation must state which items are supplied. Request photographs or packing-list confirmation when replacing an installed set.
Why might one TRICONEX 9753-110 panel leave half of a 3515 module without field terminals?
TRICONEX 9753-110 provides sixteen pulse-totalizer points, while 3515 has thirty-two points. A complete 3515 installation therefore uses two matched panels with the correct 1–16 and 17–32 labeling.
Why should unused TRICONEX 9753-110 pulse-input points be shorted as directed by the manufacturer?
Floating unused inputs can collect electrical noise and create misleading activity. Apply the documented shorting practice only to unused channels and verify the point assignment before installation.
What field-sensor output should be checked before using TRICONEX 9753-110 with a 3515 pulse-totalizer module?
Confirm a compatible push-pull sensor output. The manufacturer also calls for individually shielded twisted pairs on longer runs; mechanical contacts are not suitable for this pulse-totalizer input arrangement.
What should be checked when TRICONEX 9753-110 produces unstable or missing pulse counts?
Check sensor power, polarity, push-pull output behavior, shield grounding, cable routing, terminal tightness, and the documented termination resistor. Then compare the configured input threshold and frequency with the field device.
Can TRICONEX 9753-110 be moved from a 3703E installation to a 32-point analog-input module without rewiring review?
No. Module point count, range configuration, panel quantity, labels, and cable routing can change. Reconcile the receiving module, both label sets, the loop drawings, and all field conductors before reuse.