Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

DDS02.1-W100-D

/ 4.9
1001 reviews | Need a Specific Revision?
Bosch Rexroth DDS02.1-W100-D is a 100 A DIAX02 drive-controller basic unit with internal cabinet-air cooling and digital servo feedback.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for DDS02.1-W100-D
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DDS02.1-W100-D

  • Manufacturer:
    Rexroth
  • Part Number:
    DDS02.1-W100-D
  • Product Family:
    Rexroth
  • Product Type:
    DIAX02 Drive Controller Basic Unit
  • Stock:
    1
  • Controller line / design:
    DDS02 / design 1
  • DC bus voltage:
    300 VDC ±15%
  • Maximum peak current:
    100 A
  • Peak / continuous combination:
    100 A / 40 A
  • Alternative current combination:
    60 A / 60 A
  • Motor feedback:
    Digital Servo Feedback only (D)
  • Protection:
    IP20
  • Operating ambient:
    0 to +45°C; reduced data up to +55°C
  • Storage temperature:
    -30 to +85°C
  • Dimensions:
    10.5 × 39.0 × 32.5 cm
  • Weight:
    7.5 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Configuration Build Motor & Feedback DC Bus Startup Application
  • Treat DDS02.1-W100-D as the basic unit of a configured DIAX02 controller
  • Match the D feedback version, plug-in modules, software module and firmware
  • Verify supply-unit, DC-bus, current and cabinet-cooling compatibility before replacement

Bosch Rexroth DDS02.1-W100-D is a 100 A DIAX02 drive-controller basic unit with internal cabinet-air cooling and digital servo feedback.

Bosch Rexroth DDS02.1-W100-D is a 100 A DIAX02 drive-controller basic unit with internal cabinet-air cooling and digital servo feedback. DDS02.1-W100-D identifies the unconfigured basic unit; command communication, plug-in modules, software module and firmware must be matched separately to the installed drive.

Before installation or replacement, verify the complete nameplate, compatible companion hardware, wiring or network design, saved configuration and commissioning plan.

Availability, condition, price, and shipping time for DDS02.1-W100-D are confirmed during quotation.

Bosch Rexroth DDS02.1-W100-D DIAX02 Drive Controller Basic Unit Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Inventory every installed command and auxiliary plug-in module
  • Match the software module and firmware to the approved machine record
  • Preserve module slot order and configured function before removal
  • Use the D version only with documented digital servo feedback
  • Confirm motor/controller selection and current limits for the axis
  • Verify feedback cable, shielding and connector assignment before enable
  • Confirm the compatible DIAX02 supply unit and 300 VDC bus
  • Inspect cabinet airflow and required mounting clearances
  • Restore parameters and prove controlled motion under an approved procedure
  • Machine-tool and textile-machine axes
  • Printing and packaging machinery
  • Robotics and material-handling machines
Description
DDS02.1-W100-D is the 100 A DIAX02 drive-controller basic unit with internal cabinet-air cooling and digital servo feedback.

The D feedback version, command interface, plug-in modules, software module and firmware must match the original configured axis.

Before replacement, record both type plates, installed module positions, supply unit, motor and feedback data, firmware and the approved parameter set.
Alternative Names
DDS02.1-W100-D DDS 02.1-W100-D DDS02 1 W100 D DDS021W100D Bosch Rexroth DDS02.1-W100-D Rexroth Indramat DDS02.1-W100-D Indramat DDS02.1-W100-D DIAX02 DDS02.1-W100-D
Technical notes
DDS02.1-W100-D is a DIAX02 basic unit, not a complete configured controller. The digital-feedback version, installed plug-in modules, software module, firmware and compatible supply unit must all match the original machine.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is DDS02.1-W100-D a complete configured drive controller?
No. It is the basic unit; the command communication module, auxiliary plug-in modules, software module and firmware must match the original configured controller.
Which motors can DDS02.1-W100-D use without changing the feedback design?
Only motors and feedback paths approved for the digital-servo-feedback D version should be used; a resolver-feedback unit is not a direct substitute.
Can DDS02.1-W100-D replace another DDS current or cooling version?
Not automatically. Verify the complete type code, supply unit, DC bus, current requirement, cooling method, cabinet layout and motor/controller selection data.
What must be saved before removing DDS02.1-W100-D?
Record the complete basic-unit and configuration plates, all installed module types and slots, software module, firmware, motor data, parameters, cables and active diagnostics.
Why can DDS02.1-W100-D trip after a mechanically correct replacement?
Typical causes include a mismatched software module or firmware, wrong motor-feedback version, incorrect plug-in module order, missing parameters, DC-bus faults or cooling problems.
How should the cabinet cooling for DDS02.1-W100-D be checked?
Confirm unobstructed internal cabinet airflow, specified clearances, ambient temperature, heat dissipation and fan or filter condition before applying load.
How should DDS02.1-W100-D be commissioned after installation?
Verify the configured module set and feedback, restore approved parameters, check DC-bus and control supplies, then prove enable, direction, limits and controlled motion at low risk.

Product Browsing History