Within a SIMATIC TDC processor station, Siemens 6DD1610-0AH6 is an MC510 program memory module that stores the operating system and CFC-configured CPU program.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6DD1610-0AH6
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6DD1610-0AH6

  • Manufacturer:
    Siemens
  • Part Number:
    6DD1610-0AH6
  • Product Family:
    SIMATIC TDC
  • Product Type:
    SIMATIC TDC MC510 Program Memory Module
  • Stock:
    1
  • Module Designation:
    MC510
  • Memory Technology:
    FEPROM with EEPROM parameter memory
  • Flash Capacity:
    8 MB
  • EEPROM Capacity:
    8 KB
  • Supported Processor Modules:
    CPU550 and CPU551
  • Stored Content:
    Operating system and CFC-configured processor program
  • Offline Loading:
    PCMCIA programming adapter in the engineering PC
  • Online Loading:
    Serial communication to the installed CPU module
  • Weight:
    0.0661 lbs (0.03 kg)
  • Estimated shipping dimensions:
    5.4x8.56x0.33cm
  • Tariff Code:
    85235110
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Memory Layout Processor Pairing Loading Paths Transfer Checks

Features:

  • MC510 combines an 8 MB FEPROM program area with 8 KB EEPROM.
  • The card stores both the processor operating system and its CFC project.
  • CPU550 and CPU551 modules use the documented MC510 execution.
The removable program memory keeps processor software separate from the CPU hardware.

Offline and online loading provide two paths for transferring the same target project.

Card identity, processor assignment and project revision must remain together.

The Siemens 6DD1610-0AH6 SIMATIC TDC MC510 Program Memory Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6DD1610-0AH6 SIMATIC TDC MC510 Memory Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Separating executable storage from parameter retention

  • FEPROM area: Eight megabytes hold the operating system and processor program.
  • EEPROM area: Eight kilobytes retain the documented parameter data.
  • Nonvolatile role: The saved project remains on the removable card without CPU power.
  • Capacity check: The CFC project size must fit the MC510 execution.

Assigning the MC510 to the intended SIMATIC TDC CPU

  • CPU550: The processor accepts MC510 as an additional program-memory component.
  • CPU551: The later processor is also listed with the MC510 card.
  • Slot interface: The card enters the program-memory submodule slot on the CPU.
  • Station record: The processor and slot assignment identify which program belongs on the card.

Choosing an offline or installed-card programming route

  • Offline method: A PCMCIA programming adapter writes the removed memory module.
  • Online method: A serial engineering link loads the card while it remains in the CPU.
  • Project target: Both methods must address the processor program assigned in CFC.
  • Verification: Read-back and station checks confirm that the intended project was written.

Keeping program media and station configuration synchronized

  • Card label: Record the complete 6DD1610-0AH6 identity before transfer.
  • Project revision: Match the CFC source and operating-system level to the saved image.
  • CPU destination: Confirm that the destination is the documented CPU550 or CPU551.
  • Startup review: Verify processor state and station communication after loading.
Description
In a SIMATIC TDC multiprocessor station, Siemens 6DD1610-0AH6 is the MC510 program memory module used by CPU550 and CPU551 processors. It preserves the operating system and the processor program created with the hardware configuration and CFC engineering tools.

The nonvolatile memory arrangement in 6DD1610-0AH6 combines an 8 MB FEPROM program area with an 8 KB EEPROM parameter area. The CPU reads the stored execution image from this removable module, so capacity and MC510 identity must match the project assigned to that processor slot.

Programming of 6DD1610-0AH6 can follow two distinct paths: the module can be loaded offline through a PCMCIA programming adapter, or it can be loaded online while installed in the CPU through the documented serial engineering connection. The chosen path changes how the project reaches the card but not the program assigned to the target processor.

Before moving 6DD1610-0AH6 between CPU modules, the saved CFC configuration, operating-system level and station assignment must be identified together. A readable memory card alone does not confirm that its program belongs to the destination CPU or the correct SIMATIC TDC station.
Alternative Names
6DD16100AH6 6DD1 610-0AH6 6DD1610 0AH6 Siemens 6DD1 610-0AH6 6DD1-610-0AH6 6DD1610-0AHG 6DDI610-0AH6 6DD1610 OAH6
Technical notes
Selection of Siemens 6DD1610-0AH6 requires the MC510 designation, 8 MB FEPROM capacity and a CPU550 or CPU551 processor that accepts this program-memory module.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is stored on Siemens 6DD1610-0AH6?
Siemens 6DD1610-0AH6 stores the SIMATIC TDC processor operating system together with the CFC-configured user program and associated parameter data.
Which processors accept 6DD1610-0AH6?
The documented processor pairing for 6DD1610-0AH6 is CPU550 and CPU551; another CPU requires separate compatibility evidence.
Can 6DD1610-0AH6 be programmed outside the SIMATIC TDC CPU?
Yes. 6DD1610-0AH6 can be written offline with the documented PCMCIA programming adapter, while online loading uses the serial link to the installed CPU.
Why should the CFC project revision be recorded before moving 6DD1610-0AH6?
The readable contents of 6DD1610-0AH6 do not by themselves identify the intended processor and station, so the matching CFC revision prevents a wrong program from being started.
How is 6DD1610-0AH6 distinguished from other MC500-series cards?
The full 6DD1610-0AH6 order number identifies MC510 with 8 MB FEPROM and 8 KB EEPROM rather than another capacity in the same card family.
What should be checked if a CPU does not start after installing 6DD1610-0AH6?
For 6DD1610-0AH6, verify the card seating, CPU550 or CPU551 assignment, operating-system compatibility and target project before rewriting the memory.