Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    For 6GK5722-1FC00-0AA0, Apter Power offers quotations, manuals and wireless-client selection support.

6GK5722-1FC00-0AA0

/ 4.9
1001 reviews | Need a Specific Revision?
An industrial wireless LAN client, Siemens 6GK5722-1FC00-0AA0 connects an Ethernet device to a wireless network through the SCALANCE W722-1 radio interface.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5722-1FC00-0AA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5722-1FC00-0AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5722-1FC00-0AA0
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE W722-1 IWLAN Client
  • Stock:
    1
  • Wireless Standards:
    IEEE 802.11a/b/g/h/n
  • Radio Bands:
    2.4 GHz and 5 GHz
  • Maximum Radio Data Rate:
    150 Mbit/s gross
  • Ethernet Port:
    1 RJ45; 10/100 Mbit/s
  • Antenna Connection:
    1 R-SMA female
  • Supply Voltage:
    24 V DC; 19.2–28.8 V DC
  • Current Consumption:
    0.15 A
  • Power Consumption:
    3.6 W typical
  • Protection Rating:
    IP20
  • Operating Temperature:
    0 to +55 °C
  • Storage Temperature:
    -40 to +85 °C
  • Relative Humidity:
    95% maximum at 25 °C; non-condensing
  • Mounting:
    35 mm DIN rail
  • Weight:
    0.5137 lbs (0.233 kg)
  • Estimated shipping dimensions:
    11.4×5×7.4cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Status LEDs Antenna Fitting Earth & Rail Restart Paths

Features:

  • The client supports iPCF and iPCF-MC communication functions.
  • The iPRP function is included in this iFeatures variant.
  • Network administration includes SNMP and Syslog support.
The wired and radio interfaces of 6GK5722-1FC00-0AA0 have different maximum data rates. A radio gross rate does not increase the speed rating of the attached Ethernet connection.

Management access to 6GK5722-1FC00-0AA0 supports authentication and encrypted administration methods. Management functions are separate from the client association used for network traffic.

The client configuration of 6GK5722-1FC00-0AA0 supports four manageable IP addresses. This setting is part of its client function, not a count of RJ45 sockets.

The Siemens 6GK5722-1FC00-0AA0 SCALANCE W722-1 IWLAN Client may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5722-1FC00-0AA0 SCALANCE W722-1 IWLAN Client Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Read power, Ethernet and radio states independently

  • L1 indication: The power indicator identifies whether the supply is present.
  • P1 indication: The Ethernet indicator distinguishes an established link from data activity.
  • R1 indication: Radio indication separates association from searching for a wireless connection.
  • F indication: The fault indicator also participates in startup and recovery states, so its flashing pattern matters.

Connect the radio path without twisting the antenna body

  • Connector choice: The antenna connects to the R-SMA socket designated R1 A1.
  • Tightening: Turn the connector screw cap when fitting an antenna rather than rotating the complete antenna.
  • Cabinet installation: An antenna installed outside the cabinet uses the appropriate antenna cable connection.
  • Placement: Antenna installation must follow the selected antenna and radio installation instructions.

Link the mounting arrangement to functional earth

  • Rail support: The enclosure clips onto a 35 mm DIN rail.
  • FE terminal: Functional earth connects at the supply connector rather than an Ethernet signal contact.
  • Earth lead: The earth connection to the rail must remain short; the installation limit is 150 mm.
  • Rail bonding: The mounting rail forms part of the functional-earth installation and must be bonded accordingly.

Separate restarting from restoring defaults

  • Normal restart: Restarting through management restarts the device without requesting factory-default restoration.
  • Unsaved changes: A reset-button restart can discard configuration changes that have not been saved.
  • Factory defaults: Restoring defaults overwrites the device configuration instead of merely restarting operation.
  • Firmware recovery: The bootloader provides a TFTP recovery path distinct from normal web management.
Description
Ethernet-to-radio connectivity is provided by the Siemens 6GK5722-1FC00-0AA0 SCALANCE W722-1 industrial wireless LAN client. Its RJ45 connection serves the wired side of the link, while the radio associates with a wireless access point; the device is not an access point itself.

Configuration of 6GK5722-1FC00-0AA0 is available through web-based management, a command-line interface and Siemens engineering tools. PROFINET IO diagnostics and network-management services provide different access paths to device information rather than additional physical Ethernet ports.

A separate DC connection supplies 6GK5722-1FC00-0AA0; operating power is not delivered through its Ethernet port. Functional earth is provided at the power connector, separating the protective installation connection from the Ethernet data path.

The regional execution of 6GK5722-1FC00-0AA0 is intended for use outside the USA and Israel. Radio operation remains subject to the approval and channel requirements of the country where the device is installed.
Alternative Names
6GK57221FC000AA0 6GK5722 1FC00 0AA0 6GK5 722-1FC00-0AA0 Siemens 6GK5722-1FC00-0AA0 6GK5722-1FC00-0AA0 SCALANCE W722-1 IWLAN Client 6GK5722-1FCOO-OAAO 6GK5722-IFC00-0AA0 SCALANCE W722-1 IWLAN Client 6GK5722-1FC00-0AA0
Technical notes
The Siemens 6GK5722-1FC00-0AA0 client variant provides iPCF, iPCF-MC and iPRP functions; its regional version excludes the USA and Israel.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Will 6GK5722-1FC00-0AA0 replace the access point in a wireless network?
No access-point mode is provided by 6GK5722-1FC00-0AA0; an appropriate access point is still required for its client connection.
Can an Ethernet PoE injector power 6GK5722-1FC00-0AA0?
A separate DC supply is required for 6GK5722-1FC00-0AA0. Its RJ45 interface does not provide a Power over Ethernet power-input function.
Where can a C-PLUG configuration module be inserted in 6GK5722-1FC00-0AA0?
Neither a C-PLUG nor a KEY-PLUG slot is provided on 6GK5722-1FC00-0AA0, so configuration transfer cannot rely on inserting either plug type.
Should a 150 Mbit/s radio setting produce a 150 Mbit/s wired link on 6GK5722-1FC00-0AA0?
The wired port of 6GK5722-1FC00-0AA0 remains a 10/100 Mbit/s interface. Wireless gross data rate and usable end-to-end throughput are not the same measurement.
Are wireless distribution links supported by 6GK5722-1FC00-0AA0?
WDS is not supported by 6GK5722-1FC00-0AA0; the client function must not be treated as a wireless distribution-system bridge.

Product Browsing History