Features:
- The 6SX7010-0FJ00 retrofit kit supplies an SLB board, matching connectors, and a Short Guide.
- Its optical interface provides separate SIMOLINK input and output connections for a serial fibre ring.
- The miniature-format SLB board installs through an ADB adapter inside SIMOREG DC-MASTER electronics.
The complete ordering reference groups the communication board with the fitting components needed for the retrofit configuration.
Incoming optical data passes through the SLB and continues from its output to the next SIMOLINK node.
Red, green, and yellow indicators separate board-power and optical-link checks at the installed option.
Apter Power assists with pricing and access to product documentation for Siemens 6SX7010-0FJ00 SLB SIMOLINK Board Retrofit Kit.
Siemens 6SX7010-0FJ00 SLB SIMOLINK Board Retrofit Kit Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
What the retrofit order supplies
- Option Board: The kit contains the SLB SIMOLINK miniature-format board.
- Connectors: The retrofit ordering form includes the connectors needed with the option board.
- Guide: A Short Guide accompanies the retrofit kit.
- Bare-Board Reference: The board by itself is identified as 6SE7090-0XX84-0FJ0.
How the optical ring passes through the board
- Incoming Link: The SIMOLINK input receives the optical data stream from the preceding node.
- Outgoing Link: The SIMOLINK output forwards the stream to the following node.
- Network Timing: Data transfer runs at 11 MBaud with no more than three clock cycles of delay.
- Distance Choice: Plastic and glass fibre have different permitted link lengths of 40 m and 300 m.
Board-stack and environmental boundaries
- Adapter Layer: An ADB adapter board is mandatory for the miniature-format SLB hardware.
- Cooling: The installed board relies on self-cooling rather than a dedicated fan.
- Climate: The specified operating climate is class 3K3 without condensation.
- Pollution Boundary: The mounting environment is limited to pollution degree 2.
Local checks available at the SLB option
- Red Indicator: The red LED participates in board and communication-state indication.
- Green Indicator: The green LED provides an additional operating-state cue.
- Yellow Indicator: The yellow LED completes the local three-colour status display.
- Power Check: The indicator review should be paired with checks of the internal 5 V and external 24 V supplies.