    Apter Power provides quotations, manuals and control-board matching for Siemens C98043-A7001-L1 6RY1703-0AA00.

C98043-A7001-L1 6RY1703-0AA00

/ 4.9
1001 reviews | Need a Specific Revision?
The Siemens C98043-A7001-L1 6RY1703-0AA00 is the CUD1 control electronics board for SIMOREG DC-MASTER converter control and signal processing.
In Stock
Fast Shipping Available
Get a quick price for C98043-A7001-L1 6RY1703-0AA00
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for C98043-A7001-L1 6RY1703-0AA00

  • Manufacturer:
    Siemens
  • Part Number:
    C98043-A7001-L1 6RY1703-0AA00
  • Product Family:
    Siemens SIMOREG DC-MASTER
  • Product Type:
    CUD1 Control Electronics Board
  • Stock:
    1
  • Product State:
    A1 and A2 hardware
  • Supported Software:
    Version 1.xx and 2.xx
  • Main Analog Inputs:
    Terminals 4/5 and 6/7
  • Analog Outputs:
    Terminals 14 and 16
  • Real-Time Current Output:
    Terminal 12; 5 V at rated current
  • Serial Interface 1:
    X300; RS232 / RS485
  • Serial Interface 2:
    Terminals 56–60; RS485
  • Temperature Input:
    KTY84 or PTC
  • Parameter Storage:
    External EEPROM on A7009 through X109
  • Weight:
    0.5071 lbs (0.23 kg)
  • Estimated shipping dimensions:
    26.5×12.5×1.3cm
  • Tariff Code:
    85049099
  • Country of origin:
    Austria
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Analog Paths Serial Interfaces Memory Boundary Diagnostic Signals

Features:

  • Coordinates armature and field control in SIMOREG DC-MASTER.
  • Processes analog, serial and pulse-encoder signal paths.
  • Uses the external A7009 EEPROM for non-volatile parameters.
The CUD1 architecture places converter calculations and signal conversion on one control board.

Ground-referenced analog channels connect measured values and command inputs to the control processor.

Hardware version L1 belongs to product states A1/A2 and is paired with software generations 1.xx and 2.xx.

The Siemens C98043-A7001-L1 6RY1703-0AA00 CUD1 Control Electronics Board may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens C98043-A7001-L1 6RY1703-0AA00 CUD1 Control Electronics Manuals,Datasheets,LinkImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

How measured values enter and leave CUD1

  • Input 1: Terminals 4/5 feed the main setpoint or analog-select channel.
  • Input 2: Terminals 6/7 provide a second ground-referenced analog channel.
  • Outputs: Terminals 14 and 16 carry configurable analog values.
  • Current signal: Terminal 12 delivers 5 V at rated armature current.

Two independent communication routes

  • G-SST1: X300 supports the first RS232 or RS485 path.
  • G-SST2: Terminals 56–60 form the second RS485 path.
  • Reference: Each serial route includes its defined signal ground.
  • Separation: The two interfaces occupy different physical connection points.

Where non-volatile data is retained

  • Storage device: Parameter data resides in the EEPROM on A7009.
  • Board link: CUD1 reaches that memory through connector X109.
  • Power loss: Stored parameter and process data remain non-volatile.
  • Hardware rule: L1 hardware belongs to product states A1 and A2.

Fault checks associated with CUD1

  • F063: Verifies analog input and output compensation data.
  • F064: A hardware watchdog checks the firing-pulse calculation cycle.
  • F068: Monitors the main setpoint and analog measuring channels.
  • Saturation limit: Inputs above about 11.3 V can trigger F068.
Description
Siemens C98043-A7001-L1 6RY1703-0AA00 is the CUD1 control electronics board in the SIMOREG DC-MASTER platform. It performs open-loop and closed-loop control for the armature and field while coordinating the converter's measured values, command signals and firing-pulse calculations.

Analog processing on C98043-A7001-L1 6RY1703-0AA00 includes ground-referenced inputs at terminals 4/5 and 6/7, analog outputs at terminals 14 and 16, and a real-time armature-current signal at terminal 12. The terminal-12 output reaches 5 V when the rated armature current is present.

Two serial paths are available to C98043-A7001-L1 6RY1703-0AA00. The first operates through X300 for RS232 or RS485 communication, while the second uses terminals 56–60 as an RS485 interface. Pulse-encoder evaluation and KTY84/PTC motor-temperature sensing are integrated into the surrounding CUD1 signal structure.

Non-volatile parameter values are not stored on C98043-A7001-L1 6RY1703-0AA00 itself. They reside in the EEPROM on the A7009 rear-panel wiring assembly and communicate with CUD1 through X109; product states A1 and A2 require software versions 1.xx or 2.xx.
Alternative Names
C98043A7001L1 6RY17030AA00 C98043 A7001 L1 6RY1703 0AA00 Siemens C98043-A7001-L1 6RY1703-0AA00 Siemens 6RY1703-0AA00 CUD1 Board SIMOREG CUD1 C98043-A7001-L1 6RY17030AA00 Control Electronics C98043-A7001-L1 CUD1 Control Board C98O43-A7OO1-L1 6RY17O3-OAAOO
Technical notes
Siemens C98043-A7001-L1 6RY1703-0AA00 is the CUD1 processor board for product states A1/A2 and software versions 1.xx–2.xx.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which software versions belong with Siemens C98043-A7001-L1 6RY1703-0AA00?
Product states A1 and A2 with the L1 CUD1 board are limited to software versions 1.xx and 2.xx.
Where are parameters retained when Siemens C98043-A7001-L1 6RY1703-0AA00 loses power?
The non-volatile values are held in the EEPROM on A7009 and accessed from CUD1 through X109.
What should be checked when F068 appears with Siemens C98043-A7001-L1 6RY1703-0AA00?
Inspect the analog measuring circuits at terminals 4/5 and 6/7; input levels above about 11.3 V can saturate a channel.
How do the two serial routes differ on Siemens C98043-A7001-L1 6RY1703-0AA00?
G-SST1 is available at X300 as RS232/RS485, while G-SST2 uses terminals 56–60 as RS485.
Can Siemens C98043-A7001-L1 6RY1703-0AA00 be exchanged with the L2 hardware without checking software?
No. L1 is tied to software 1.xx–2.xx, whereas the L2 generation is associated with software 3.xx.
Which output gives a direct current-related signal on Siemens C98043-A7001-L1 6RY1703-0AA00?
Terminal 12 provides the real-time armature-current signal and reaches 5 V at rated current.