Features:
- The spare-part scope is the IPD card rather than the complete SINAMICS S120 Motor Module.
- Its order assignment is tied to an air-cooled Motor Module in the 500–690 V class.
- The documented electronics arrangement secures the card at the Control Interface Module connection.
Selection begins with the installed Motor Module rating because the 900 kW and air-cooled attributes are part of this card's assignment.
The IPD board connects at X45 on the Control Interface Module and remains mechanically separate from the surrounding chassis power components.
Keeping the full 8AA0 suffix prevents the board-level spare from being confused with adjacent voltage, power or hardware assignments.
The Siemens 6SL3352-3AG38-8AA0 SINAMICS S120 Replacement IPD Card may be available for purchase and support from Apter Power.
Siemens 6SL3352-3AG38-8AA0 SINAMICS S120 Replacement IPD Card Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Position inside the electronics assembly
- Host Section: 6SL3352-3AG38-8AA0 belongs to the IPD-card position associated with the Control Interface Module.
- Board Connector: The electrical connection is made through X45 on the Control Interface Module.
- Mechanical Hold: Two retaining screws secure the IPD card before the surrounding electronics are handled.
- Assembly Boundary: The card remains a separate service item from both the Control Interface Module and complete Motor Module.
Documented access sequence
- Safe State: The drive line-up is disconnected and the power block area made accessible before card removal.
- Cover Access: The protective cover is removed to reach the electronics assembly.
- Fastener Release: The two IPD-card screws are taken out before the board is moved.
- Connector Release: The IPD card is then withdrawn from X45 rather than pulled with the Control Interface Module.
Restoring the board connection
- Reverse Sequence: Installation follows the documented removal steps in reverse order.
- Plug Seating: The X45 plug-in connection must be carefully established and checked for secure seating.
- Board Retention: Both IPD-card retaining points are restored before the protective cover is closed.
- Cable Protection: Signal cables remain clear of the surrounding power-block movement during reassembly.
Keeping the spare within its assignment
- Voltage Boundary: 6SL3352-3AG38-8AA0 is assigned to the 500–690 V Motor Module class.
- Power Boundary: The associated air-cooled Motor Module carries the 900 kW designation.
- Cooling Boundary: The official spare description specifies an air-cooled host assembly.
- Order-Code Check: All sections of 6SL3352-3AG38-8AA0 must match before treating the board as the required IPD spare.