    Apter Power supports 7MF0340-1DM01-5AF2-Z A01+E01+H01 quotations, documentation, and exact configuration review.

7MF0340-1DM01-5AF2-Z A01+E01+H01

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 is a SITRANS P320 differential pressure transmitter that converts pressure or flow differential into a 4-20 mA HART signal.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 7MF0340-1DM01-5AF2-Z A01+E01+H01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 7MF0340-1DM01-5AF2-Z A01+E01+H01

  • Manufacturer:
    Siemens
  • Part Number:
    7MF0340-1DM01-5AF2-Z A01+E01+H01
  • Product Family:
    Siemens SITRANS / MultiRanger
  • Product Type:
    SITRANS P320 Differential Pressure Transmitter
  • Stock:
    1
  • Measurement Variable:
    Differential pressure and flow
  • Output Signal:
    4–20 mA with HART communication
  • Pressure Class:
    PN160
  • Maximum Measuring Span:
    60 mbar (24.11 inH2O)
  • Measuring Cell Fill Fluid:
    Silicone oil
  • Process Connection:
    Oval flange
  • Flange Fastening Thread:
    M10 for PN160
  • Process Diaphragm Material:
    Stainless steel 316L / 1.4404
  • Pressure Flange Material:
    Stainless steel 316L / 1.4408
  • Housing:
    Die-cast aluminum dual-chamber enclosure
  • Electrical Entries:
    2 x M20 x 1.5
  • Local Display:
    Included
  • Explosion Protection:
    Non-Ex version
  • External Operation:
    Push-button cover fitted
  • Mounting Bracket:
    Electrogalvanized steel
  • Weight:
    8.8185 lbs (4 kg)
  • Tariff Code:
    90262020
  • Country of origin:
    France
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Pressure Path HART Loop Process Assembly Housing Setup

Features:

  • SITRANS P320 converts differential pressure into a two-wire 4-20 mA signal.
  • HART communication shares the analog loop for configuration and device data.
  • A stainless-steel oval-flange process assembly applies pressure to the filled measuring cell.
The order code fixes the pressure class, span, wetted materials, display, housing and cable entries.

The local display and external push buttons provide on-device observation and setup.

Process sealing, manifold alignment and loop grounding belong to separate installation checks.

The Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 SITRANS P320 Differential Pressure Transmitter is listed as available from the original manufacturer (OEM).
Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 SITRANS P320 Differential Pressure Transmitter Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Following process pressure through the measuring assembly

  • High and low sides: The manifold routes each process pressure to its assigned oval-flange port.
  • Isolation diaphragms: Stainless-steel diaphragms separate the process medium from the cell fill fluid.
  • Filled cell: Silicone oil transfers the differential force to the sensing element.
  • Converted value: Electronics translate the measured difference into loop current and HART data.

Keeping analog measurement and digital communication on one pair

  • Loop supply: The control loop powers the transmitter and carries the 4–20 mA value.
  • Digital overlay: HART exchanges settings and diagnostics without replacing the analog current.
  • Control input: The receiving analog channel reads the current assigned to the measured differential pressure.
  • Commissioning check: Polarity, loop resistance, shielding and device address are verified together.

Matching flange hardware to the installed pressure connection

  • Pressure class: The PN160 configuration defines the mechanical pressure boundary.
  • Fastening thread: M10 flange hardware belongs to this configured pressure class.
  • Wetted material: 316L stainless steel is retained across the documented diaphragm and flange surfaces.
  • Manifold fit: Port spacing, seals and bolt engagement are checked before pressure is applied.

Separating field wiring from measurement electronics

  • Cable entries: Two M20 x 1.5 openings accept the documented glands or plugs.
  • Terminal chamber: Loop conductors terminate away from the sensing electronics.
  • Local indication: The fitted display presents the transmitter value at the device.
  • External control: Covered push buttons allow local operation while retaining the enclosure arrangement.
Description
Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 is the SITRANS P320 differential pressure transmitter configured for pressure or flow measurement through a 4-20 mA HART loop. The measuring cell converts the pressure difference at the two process ports into the electrical value used by the control system.

Across the oval-flange assembly, 7MF0340-1DM01-5AF2-Z A01+E01+H01 applies the differential pressure to a silicone-oil-filled measuring cell while stainless-steel diaphragms isolate the process media. The PN160 flange and M10 fastening configuration must agree with the manifold and mounting hardware before the process connections are tightened.

Signal power and HART communication share the two-wire loop of 7MF0340-1DM01-5AF2-Z A01+E01+H01. The local display presents the measured value at the transmitter, while HART carries parameter and diagnostic data over the same analog wiring without replacing the 4-20 mA process signal.

Two M20 x 1.5 cable entries route loop wiring into the dual-chamber enclosure of 7MF0340-1DM01-5AF2-Z A01+E01+H01. Separating the terminal compartment from the electronics and retaining the specified grounding, sealing, and mounting arrangement protects the measurement path during commissioning.
Alternative Names
7MF0340-1DM01-5AF2-Z A01+E01+H01 7MF03401DM015AF2ZA01E01H01 7MF 0340-1DM01-5AF2-Z A01+E01+H01 7MF0340 1DM01 5AF2 Z A01 E01 H01 Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 SITRANS P320 7MF0340-1DM01-5AF2-Z A01+E01+H01 7MF0340-1DM01-5AF2-Z+A01+E01+H01 7MF0340/1DM01/5AF2-Z A01+E01+H01
Technical notes
Before installation, verify the complete Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 order code, PN160 flange hardware, wetted materials, span, display, and cable-entry configuration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What causes Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 to show zero after the process is pressurized?
Check the Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 high- and low-side manifold valves, equalizing path, impulse lines, and configured zero before changing span settings.
Which manifold details must be verified before installing 7MF0340-1DM01-5AF2-Z A01+E01+H01?
Confirm the 7MF0340-1DM01-5AF2-Z A01+E01+H01 PN160 oval flange, M10 fastening thread, port spacing, seals, and 316L wetted-material requirement.
Can HART communication replace the analog input for Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01?
No. Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01 keeps its 4-20 mA process value on the loop while HART overlays configuration and diagnostic data.
Which records should be retained for 7MF0340-1DM01-5AF2-Z A01+E01+H01 commissioning?
Record the 7MF0340-1DM01-5AF2-Z A01+E01+H01 complete order code, calibrated range, damping, output direction, HART address, manifold orientation, and terminal wiring.
Why must every option code be checked when quoting Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01?
For Siemens 7MF0340-1DM01-5AF2-Z A01+E01+H01, the base code and A01, E01, and H01 options jointly define the supplied transmitter configuration.