Features:
- An integrated 13.56 MHz antenna exchanges data with MOBY E mobile data storage units.
- The RS422 host path connects the reader to the SIMATIC interface module.
- The sealed polyamide assembly combines the antenna, electronics and field connector.
Siemens 6GT2301-0CA00 is the MOBY E SLG 72 read/write device for medium-range inductive identification.
The reader establishes the radio coupling zone at the data carrier and returns the transferred information through its wired interface.
Mechanical spacing from metal and other readers forms part of the installation boundary because both can alter the usable field.
The Siemens 6GT2301-0CA00 MOBY E SLG 72 Read/Write Device may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GT2301-0CA00 MOBY E SLG 72 Read/Write Device Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Positioning the mobile data unit
- Working Region: Normal communication is arranged within the documented 0 to 70 mm zone.
- Outer Boundary: The 100 mm limiting distance marks the edge of coupling rather than a normal operating target.
- Alignment: The integrated antenna face and the data carrier must remain inside the specified field geometry.
- Motion Check: Available dwell time depends on how long the mobile data unit remains in the usable zone.
Connecting the reader to the host
- Signal Path: RS422 carries reader data to the SIMATIC interface module at 19,200 baud.
- Reader Run: The specified 24 V and conductor condition permits up to 120 m between the two devices.
- Route Limit: The complete shielded data-cable path is documented for lengths up to 1,000 m.
- Voltage Check: Cable length and conductor size must preserve the required voltage at the reader terminals.
Protecting the antenna field
- Metal Boundary: Maintain the specified 40 mm metal-free area around the reader.
- Reader Separation: Adjacent units require more than 800 mm spacing.
- Fastening: Two M5 points secure the housing with tightening torque limited to 2 Nm.
- Connector Seal: The six-pin connection must be correctly assembled to preserve the enclosure boundary.
Allowing for startup and operation
- Supply Window: The reader operates from a 20 to 30 V DC source.
- Normal Demand: Typical current is 180 mA after startup.
- Startup Demand: A brief 700 mA current must be supported when power is applied.
- Field Assembly: The integrated electronics and antenna share the same supplied enclosure and connector path.