Technical specifications for 6GT2811-6AA10-2AA0

  • Manufacturer:
    Siemens
  • Part Number:
    6GT2811-6AA10-2AA0
  • Product Family:
    Siemens Simatic Net
  • Product Type:
    SIMATIC RF600 RF680R CMIIT UHF RFID Reader
  • Stock:
    1
  • Operating Frequency:
    920–925 MHz
  • RF Transmit Power:
    3–2000 mW
  • Radio Protocols:
    EPCglobal Class 1 Gen 2 V2; ISO/IEC 18000-62/-63
  • Maximum Radio Transfer Rate:
    400 kbit/s
  • External Antennas:
    4
  • Antenna Connection:
    RP-TNC
  • Communication Standards:
    Ethernet, PROFINET, OPC UA, EtherNet/IP and RS422
  • Ethernet Ports:
    2 x M12, 4-pin, D-coded
  • RS422 Port:
    M12, 8-pin
  • Digital Inputs / Outputs:
    4 / 4
  • I/O Connection:
    M12, 12-pin female
  • Supply Voltage:
    24 V DC nominal; 20–30 V DC range
  • Typical Current at 24 V:
    0.38 A
  • Protection Class:
    IP65
  • Operating Temperature:
    -25 to +55 °C
  • Antenna Cable Length:
    1–40 m
  • Status Display:
    Two LED rows with 8 and 9 LEDs
  • Weight:
    5.2911 lbs (2.4 kg)
  • Estimated shipping dimensions:
    25.8x25.8x8cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals RFID Processing Network Paths I/O Control Mounting Limits

Features:

  • Four external antenna connections let one reader serve several RF600 antenna positions.
  • Industrial Ethernet and RS422 provide separate routes for reader data and network integration.
  • Four digital inputs and four digital outputs exchange field states through a dedicated connector.
The RF680R CMIIT executes UHF tag reads and writes within the radio band assigned to this regional variant.

Network telegrams, serial communication and discrete control signals leave the reader through different M12 interfaces.

Status LEDs separate reader, antenna, network and I/O indications so the active path can be identified at the enclosure.

The Siemens 6GT2811-6AA10-2AA0 RF680R CMIIT RFID Reader may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GT2811-6AA10-2AA0 RF680R CMIIT RFID Reader Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Moving tag data through the reader

  • Air interface: RF600 transponders exchange EPCglobal or ISO/IEC data with the connected external antennas.
  • Multi-tag operation: The reader can identify more than one transponder during the same acquisition sequence.
  • Write timing: Write access takes longer per user-data byte than read access and should be allowed for in the command cycle.
  • Network result: Completed tag data is presented to the configured Ethernet, OPC UA, EtherNet/IP or RS422 path.

Separating Ethernet and serial communication

  • Ethernet pair: Two D-coded M12 ports carry the Industrial Ethernet connection and PROFINET functions.
  • OPC UA server: The integrated server exposes supported reader information through the Ethernet side.
  • RS422 route: The eight-pin M12 serial interface connects through a compatible communication module when that path is used.
  • Topology status: LLDP, DCP and Media Redundancy Protocol support network discovery and ring behavior on the Ethernet connection.

Keeping field commands separate from tag traffic

  • Input channels: Four digital inputs accept field states through the twelve-pin female M12 connector.
  • Output channels: Four digital outputs return reader-related control signals through that same dedicated I/O connection.
  • Port separation: Discrete signals do not share either of the D-coded Ethernet sockets or the RS422 connector.
  • Power reference: The I/O arrangement operates with the reader supplied from its specified 24 V DC input range.

Applying the enclosure and cable boundaries

  • Mounting methods: VESA 100, a 35 mm top-hat rail and the documented Siemens profile rails are supported with the matching hardware.
  • Metal clearance: The specified reader construction permits a zero-millimeter mounting distance from metal surfaces.
  • Antenna leads: External antenna cables are selected within the documented one-to-forty-meter range.
  • Cold start: At temperatures below -20 °C, the reader requires ten minutes of warm-up before normal operation.
Description
Within the SIMATIC RF600 identification system, Siemens 6GT2811-6AA10-2AA0 is an RF680R CMIIT UHF reader that turns transponder exchanges into data for connected automation networks. Four external antenna paths form the radio side of the reader while its wired interfaces deliver the resulting information to the control system.

Radio communication on 6GT2811-6AA10-2AA0 uses the 920–925 MHz CMIIT band and the EPCglobal Class 1 Gen 2 V2 or ISO/IEC 18000-62/-63 protocol path. The reader can process multiple tags, and its adjustable transmit power must be set together with the selected antennas and regional approval limits.

Two D-coded M12 Ethernet ports on 6GT2811-6AA10-2AA0 carry PROFINET, EtherNet/IP, TCP/IP and OPC UA traffic, whereas the eight-pin M12 connection provides the separate RS422 path. Four digital inputs and four digital outputs use their own twelve-pin M12 connector, keeping field control signals apart from RFID network traffic.

Power for 6GT2811-6AA10-2AA0 enters through the eight-pin 24 V DC supply connector. Its IP65 housing can be fixed by VESA 100 or the documented rail adapters, and operation below -20 °C requires the specified ten-minute warm-up before the reader handles normal traffic.
Alternative Names
6GT28116AA102AA0 6GT 2811-6AA10-2AA0 6GT2811 6AA10 2AA0 Siemens 6GT2811-6AA10-2AA0 SIMATIC RF600 6GT2811-6AA10-2AA0 RF680R CMIIT 6GT2811-6AA10-2AA0 6GT2811-6AA1O-2AA0 6GT281I-6AA10-2AA0
Technical notes
Siemens 6GT2811-6AA10-2AA0 is the CMIIT 920–925 MHz RF680R variant. Match external antennas, regional radio settings and the separate network and I/O connectors to this exact suffix.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How do I distinguish 6GT2811-6AA10-2AA0 from another RF680R regional version?
The 920–925 MHz CMIIT radio band and the full suffix identify 6GT2811-6AA10-2AA0; another regional RF680R order number is not the same configuration.
Which connector on 6GT2811-6AA10-2AA0 carries PROFINET rather than RS422?
PROFINET on 6GT2811-6AA10-2AA0 uses the two four-pin D-coded M12 Ethernet ports, while RS422 uses the separate eight-pin M12 connector.
Can the four field inputs of 6GT2811-6AA10-2AA0 share the Ethernet sockets?
No. The four inputs and four outputs of 6GT2811-6AA10-2AA0 use a dedicated twelve-pin M12 connector and remain separate from Ethernet traffic.
What must be allowed before 6GT2811-6AA10-2AA0 starts below -20 °C?
A ten-minute warm-up period is required for 6GT2811-6AA10-2AA0 below -20 °C before normal reader operation begins.
Where should external antennas be connected on 6GT2811-6AA10-2AA0?
Connect as many as four supported external antennas to the RP-TNC antenna points of 6GT2811-6AA10-2AA0 and keep each cable within the documented length range.
Why should the exact supply range be checked for 6GT2811-6AA10-2AA0?
Although rated at 24 V DC, 6GT2811-6AA10-2AA0 specifies a 20–30 V DC input range, so the eight-pin supply connection must stay inside that boundary.