Features:
- The integrated 2.4 GHz antenna provides an adjustable radio range for MOBY U data carriers.
- Multi-carrier processing identifies as many as 12 mobile data units inside the read field.
- RS422 host communication, a service port and synchronization use separate connection paths.
Siemens 6GT2501-0CA00 is the MOBY U SLG U92 read/write device with an RS422 controller interface.
Its configurable radio boundary lets the installed reader match the required detection zone instead of operating at one fixed distance.
Search and communication modes coordinate carrier discovery and data exchange, while synchronization organizes neighboring reader fields.
The Siemens 6GT2501-0CA00 MOBY U SLG U92 RS422 Read/Write Device may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GT2501-0CA00 MOBY U SLG U92 RS422 Read/Write Device Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Defining the usable radio zone
- Selectable Boundary: The limiting range can be set between 0.15 and 3 m.
- Step Size: Range changes are made in documented 0.5 m increments.
- Working Margin: Normal operation is planned at about 75 percent of the selected limiting distance.
- Motion Relation: Carrier speed, transfer size and time inside the configured field must be considered together.
Organizing several data units
- Field Population: Up to 12 mobile data units can be present in the reader zone.
- Search State: The reader scans the configured field before establishing an active transfer.
- Communication State: Data exchange begins after a carrier has been recognized.
- Timing Boundary: Recording all 12 units can require as much as two seconds.
Controlling neighboring radio fields
- Synchronization Group: The dedicated line coordinates as many as three readers.
- Cable Boundary: The synchronization route is documented for a maximum of 30 m.
- Unsynchronized Layout: Readers without synchronization require at least 6 m separation.
- Field Planning: Selected ranges and physical spacing are evaluated as one installation arrangement.
Separating control and service traffic
- Controller Path: The shielded RS422 link carries 3964R host communication.
- Automatic Rate: The main interface adapts within the supported 19.2 to 115.2 kbit/s range.
- Service Path: A separate RS232 connection supports commissioning at 19.2 kbit/s.
- External Inputs: Two digital inputs provide additional control signals to the reader.