6ES7650-1AM30-6XX0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7650-1AM30-6XX0 is a PCS 7 marshalling terminal assembly that connects ten failsafe ET 200M relay outputs to field loads through fused Form C contacts.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7650-1AM30-6XX0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7650-1AM30-6XX0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7650-1AM30-6XX0
  • Product Family:
    Siemens Simatic PCS 7 System
  • Product Type:
    10-Channel Failsafe Relay Output Marshalling Terminal Assembly
  • Stock:
    1
  • Relay Output Channels:
    10
  • Contact Arrangement:
    Form C, NO / COM / NC
  • Compatible I/O Module:
    6ES7326-2BF10-0AB0, E-Stand 3 or higher
  • Power Input:
    21.6 to 28.8 V DC
  • Maximum Current, All Outputs On:
    0.820 A
  • Normal Current, All Outputs Off:
    0.575 A
  • Power Consumption:
    7 W
  • Module Fuse:
    1.0 A
  • Channel Fuse:
    0.10 A
  • Maximum Relay Current:
    5 A at 24 V DC or 120 to 230 V AC
  • Maximum Switched Power:
    150 W or 1250 VA
  • Conductor Range:
    0.205 to 2.08 mm²; 24 to 14 AWG
  • Mounting:
    35 mm DIN rail
  • Operating Temperature:
    -25 to 60 °C
  • Relative Humidity:
    5 to 95%, non-condensing
  • Functional Safety Level:
    SIL 2
  • DC Overvoltage Category:
    Category III, 150 V maximum
  • AC Overvoltage Category:
    Category II, 250 V maximum
  • Tariff Code:
    85371091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Power Distribution Relay Channels Voltage Grouping Module Cabling

Features:

  • Ten failsafe relay channels convert ET 200M digital outputs into Form C field contacts.
  • Two diode-ORed 24 V DC feeds supply the internal electronics and support monitored power continuity.
  • Module and channel fuses separate control-side power from individual field-load faults.
A compatible failsafe output module drives the relays of Siemens 6ES7650-1AM30-6XX0 through the dedicated MTA cable.

Each 6ES7650-1AM30-6XX0 channel then exposes normally open, common, and normally closed terminals to the field circuit.

Protection and common-voltage rules on 6ES7650-1AM30-6XX0 determine how the ten contacts may be grouped for AC or DC loads.

The Siemens 6ES7650-1AM30-6XX0 PCS 7 Ten-Channel Failsafe Relay Output Marshalling Terminal Assembly may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7650-1AM30-6XX0 PCS 7 Ten-Channel Failsafe Relay Output Marshalling Terminal Assembly Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Dual Supply and Internal Protection

  • Input A and B: Two 24 V DC sources enter through separate terminals and feed the electronics through diode isolation.
  • Power indication: Individual front LEDs show whether each documented supply path is present.
  • Module fuse: The 1.0 A fuse protects the module-level electronics supply.
  • Grounding point: The ground stud bonds the marshalling assembly to the required protective connection.

Control Signal to Field Contact

  • Module command: The failsafe ET 200M output module energizes the corresponding relay through the dedicated cable.
  • Contact set: Each channel provides normally open, common, and normally closed field terminals.
  • Channel fuse: A 0.10 A fuse separates an individual channel from the remaining relay group.
  • Load boundary: External branch protection remains required for the connected AC or DC field load.

Shared Load Rules for Ten Outputs

  • AC grouping: All AC channels in one assembly must use the same phase.
  • High DC grouping: DC circuits above 150 V must use one common voltage level across the assembly.
  • Lower DC mixing: Documented mixed DC levels are permitted only up to the stated 150 V boundary.
  • Category check: Wiring must satisfy the specified overvoltage category for the selected AC or DC load.

MTA to Failsafe I/O Connection

  • Supported module: The documented interface is the 6ES7326-2BF10-0AB0 failsafe output module at E-Stand 3 or later.
  • Cable choice: The specified 6ES7922 cable connects the marshalling assembly to the module connector.
  • Single or dual module: The MTA arrangement can connect the documented one- or two-module configuration.
  • Rail position: A 35 mm DIN rail supports the assembly while leaving fuse and terminal access available.
Description
Siemens 6ES7650-1AM30-6XX0 is a ten-channel failsafe relay-output marshalling terminal assembly for SIMATIC PCS 7 and ET 200M. It connects a compatible 6ES7326-2BF10-0AB0 digital output module to field circuits that require Form C relay contacts.

Two 24 V DC feeds enter 6ES7650-1AM30-6XX0 through separate A and B terminals and are diode-ORed for the internal electronics. Individual module and channel fuses separate the electronics supply from the switched field paths, while front indicators show the state of both incoming power sources.

Each channel on 6ES7650-1AM30-6XX0 presents normally open, common, and normally closed field terminals. The relay contacts can switch the documented AC or DC load only after external branch protection, conductor size, overvoltage category, and the shared-voltage restrictions for the ten-channel group have been checked.

Installed on a 35 mm rail, 6ES7650-1AM30-6XX0 uses dedicated cables to reach one or two failsafe output modules. Its power-monitor connector, ground stud, pluggable field terminals, and fused channel layout keep supply supervision, module wiring, and load wiring physically distinct.
Alternative Names
6ES76501AM306XX0 6ES7650 1AM30 6XX0 6ES7 650 1AM30 6XX0 Siemens 6ES7650-1AM30-6XX0 6ES7650-1AM30-6XX0 10-channel relay MTA PCS 7 relay MTA 6ES7650-1AM30-6XX0 6ES7650-1AM3O-6XXO 6ES76S0-1AM30-6XX0
Technical notes
Dual diode-ORed DC feeds and separately fused Form C channels let Siemens 6ES7650-1AM30-6XX0 isolate module power from field-load switching.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which ET 200M module connects to 6ES7650-1AM30-6XX0?
Siemens 6ES7650-1AM30-6XX0 is documented for the 6ES7326-2BF10-0AB0 failsafe output module at E-Stand 3 or higher.
Why are two power feeds provided on 6ES7650-1AM30-6XX0?
The A and B inputs of 6ES7650-1AM30-6XX0 are diode-ORed so one healthy 24 V DC path can continue feeding the internal electronics.
Can different AC phases be switched by one 6ES7650-1AM30-6XX0?
No. The ten AC channels of 6ES7650-1AM30-6XX0 must use the same phase to satisfy the documented grouping rule.
Why is external load protection still required for 6ES7650-1AM30-6XX0?
The internal fuses of 6ES7650-1AM30-6XX0 protect module and channel circuitry; the connected field branch still needs correctly rated protection.
What should be checked when one 6ES7650-1AM30-6XX0 output does not switch?
Check the 6ES7650-1AM30-6XX0 channel fuse, module command, NO/COM/NC terminal choice, field supply, and external branch protection.
How should 6ES7650-1AM30-6XX0 conductors be selected?
Use the documented 0.205 to 2.08 mm² conductor range for 6ES7650-1AM30-6XX0 and size the field wiring for the actual protected load.