Features:
- One internal position loop compares the host command with encoder feedback.
- An analog output sends the calculated command value to the connected drive.
- Seven inputs and seven outputs coordinate motion-related field conditions.
Siemens 6FM1721-3AA20 converts host position commands and encoder feedback into one controlled-axis result.
Connector X4 supplies the actual-position signal used by 6FM1721-3AA20 for the position comparison.
The analog output and field I/O of 6FM1721-3AA20 connect the calculation to the drive and machine signals.
The Siemens 6FM1721-3AA20 WF 721 Single-Axis Positioning Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6FM1721-3AA20 WF 721 Single-Axis Positioning Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Command and Feedback Flow
- Host command: The SIMATIC program transfers the requested motion and parameter data to the module.
- Encoder feedback: X4 receives incremental pulses or serial position information from the measuring system.
- Internal comparison: The module calculates the position difference and motion response for one axis.
- Drive command: X3 sends the resulting -10 to +10 V analog command to the drive.
Actual-Position Interfaces
- Incremental input: Pulse feedback is accepted up to the documented 250 kHz limit.
- Serial input: A serial encoder can transfer position data at 125 kbit/s.
- Encoder supply: The internal 5 V path can feed the connected encoder within its current limit.
- Commissioning: Encoder type, direction, scaling, zero reference, and wiring must match the parameter set.
Machine Signals and Supply
- Channel count: The module provides seven digital inputs and seven digital outputs.
- X7 group: Six input/output channels and the external 24 V DC field supply use connector X7.
- Enable path: The documented control-enable signal is carried on the command interface.
- Output limit: Each digital output must remain within the specified 500 mA current boundary.
SIMATIC Addressing and Software
- Host exchange: Commands, parameters, status, and position data pass through the SIMATIC rack interface.
- Addressing: Module addresses must match the selected S5 or S7-400 hardware arrangement.
- Adapter use: The documented adapter casing is required where the target rack demands it.
- Backup scope: Preserve the PLC blocks, module parameters, addresses, encoder data, and machine interlocks.