Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Quotations, product manuals, selection, and model matching for 6ES7513-1FL01-0AB0 are coordinated by Apter Power.

6ES7513-1FL01-0AB0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7513-1FL01-0AB0 is a SIMATIC S7-1500F CPU 1513F-1 PN that executes standard and fail-safe control programs while managing PROFINET I/O.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7513-1FL01-0AB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7513-1FL01-0AB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7513-1FL01-0AB0
  • Product Family:
    Siemens Simatic S7-1500
  • Product Type:
    SIMATIC S7-1500F CPU 1513F-1 PN Fail-Safe Central Processing Unit
  • Stock:
    1
  • Hardware status:
    FS03
  • Firmware version:
    V2.9
  • Program work memory:
    450 KB
  • Data work memory:
    1.5 MB
  • Load memory:
    SIMATIC Memory Card, up to 32 GB
  • Bit execution time:
    40 ns typical
  • Supply voltage:
    24 V DC
  • PROFINET interfaces:
    1
  • Ethernet ports:
    2 x RJ45 with integrated switch
  • PROFINET role:
    IO Controller and IO Device
  • Connectable IO devices:
    128 maximum on integrated controller
  • Integrated IO address area:
    8 KB inputs and 8 KB outputs
  • Modules per rack:
    32 maximum including CPU
  • PROFIsafe:
    V2.4 / V2.6
  • Engineering:
    STEP 7 TIA Portal V17 for firmware V2.9
  • Weight:
    1.1045 lbs (0.501 kg)
  • Estimated shipping dimensions:
    15.4x15x4.6cm
  • Tariff Code:
    85371091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Fail-Safe Execution PROFINET Services Memory Flow Rack Integration

Features:

  • The CPU executes standard and fail-safe control programs in the SIMATIC S7-1500F platform.
  • A two-port PROFINET interface operates as both IO Controller and IO Device.
  • Program, data, and removable load memory use separate storage areas.
The 6ES7513-1FL01-0AB0 processes the configured user program and safety program, then exchanges their I/O data through the central rack and PROFINET network.

The integrated switch connects two Ethernet segments without adding a separate CPU interface, while IRT and isochronous functions coordinate time-sensitive I/O updates.

A SIMATIC Memory Card is required because it stores the load memory from which the CPU transfers blocks into working memory.

The Siemens 6ES7513-1FL01-0AB0 SIMATIC S7-1500F CPU 1513F-1 PN Fail-Safe Central Processing Unit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7513-1FL01-0AB0 SIMATIC S7-1500F CPU 1513F-1 PN Fail-Safe Central Processing Unit Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Standard and safety logic share one CPU

  • F-program: The CPU executes certified fail-safe blocks alongside the standard user program.
  • PROFIsafe: Safety data is exchanged with configured fail-safe devices through the supported protocol versions.
  • Memory separation: Program and data areas remain separately allocated inside CPU work memory.
  • Engineering release: The configured firmware level determines the minimum compatible TIA Portal version.

One interface performs several network roles

  • IO Controller: The CPU cyclically exchanges process data with configured PROFINET devices.
  • IO Device: The same CPU can expose configured data to a higher-level controller.
  • Integrated switch: Two RJ45 ports join the PROFINET line within one CPU interface.
  • IRT operation: Isochronous real-time traffic synchronizes time-critical I/O updates with the user program.

How project data reaches execution memory

  • Memory Card: The required card holds the removable load-memory image for the CPU project.
  • Program area: Executable blocks are transferred into the dedicated program work memory.
  • Data area: Data blocks and runtime values use the larger data work-memory allocation.
  • Retentive data: Selected values remain stored across a power interruption within the available retentive allocation.

The CPU coordinates central and distributed I/O

  • Central modules: Backplane communication maps the installed rack modules into the CPU address space.
  • Distributed devices: PROFINET brings remote device data into the same configured process image.
  • Power budget: The CPU contributes power to the backplane, so the rack configuration must remain within the available supply.
  • Diagnostics: Module and network conditions are available through the display, engineering system, and web server.
Description
Siemens 6ES7513-1FL01-0AB0 is a SIMATIC S7-1500F CPU 1513F-1 PN that executes standard and fail-safe automation programs and acts as the integrated PROFINET IO controller for distributed devices.

Program and data work memory in 6ES7513-1FL01-0AB0 are allocated separately, while the required SIMATIC Memory Card provides the removable load-memory path used to store the project and CPU data.

The two RJ45 ports of 6ES7513-1FL01-0AB0 form one integrated PROFINET interface, allowing controller, device, IRT, and shared-device traffic to use the same managed connection while remaining part of the CPU configuration.

Installed in the central S7-1500 rack, 6ES7513-1FL01-0AB0 supplies backplane power to connected modules, maps their input and output data into the process image, and reports diagnostic conditions through the CPU display, engineering system, and web services.
Alternative Names
6ES75131FL010AB0 6ES 7513-1FL01-0AB0 6ES 7513 1FL01 0AB0 Siemens 6ES7513-1FL01-0AB0 6ES7513-1FL01-0AB0 CPU 1513F-1 PN 6ES7513-1FL01-0AB0 Fail-Safe CPU 6ES7513-1FLO1-0AB0 6ES7513-1FL01-OAB0
Technical notes
Siemens 6ES7513-1FL01-0AB0 combines fail-safe program execution with one two-port PROFINET interface and requires a SIMATIC Memory Card for load memory.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why will 6ES7513-1FL01-0AB0 not start without a memory card?
The SIMATIC Memory Card provides the required load memory for 6ES7513-1FL01-0AB0, so the CPU cannot use its project without the card.
Can both Ethernet sockets on 6ES7513-1FL01-0AB0 be configured as separate PROFINET interfaces?
No. The two RJ45 sockets on 6ES7513-1FL01-0AB0 are ports of one integrated PROFINET interface and switch.
What should be matched before loading an existing project into 6ES7513-1FL01-0AB0?
Confirm the hardware status, firmware release, TIA Portal support, and safety configuration for 6ES7513-1FL01-0AB0 before downloading the project.
How does 6ES7513-1FL01-0AB0 exchange data with fail-safe remote I/O?
The 6ES7513-1FL01-0AB0 carries safety telegrams through PROFIsafe over its configured PROFINET connection.
What rack limit matters when expanding around 6ES7513-1FL01-0AB0?
A central rack with 6ES7513-1FL01-0AB0 supports the CPU plus the documented maximum number of additional modules and must remain within the backplane power budget.