Siemens 6ES7332-5RD00-0AB0 is an isolated four-channel SM 332 current output module for hazardous-area signals with diagnostics and PTB testing.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7332-5RD00-0AB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7332-5RD00-0AB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7332-5RD00-0AB0
  • Product Family:
    Siemens Simatic S7-300
  • Product Type:
    SM 332 Ex(i) Analog Output Module
  • Stock:
    1
  • Analog outputs:
    4 current outputs
  • Load voltage:
    24 V DC
  • Current ranges:
    0 to 20 mA; 4 to 20 mA
  • Resolution:
    15 bit
  • Current-output load:
    Maximum 500 Ohm
  • Shielded cable length:
    Maximum 200 m
  • Diagnostics:
    Yes
  • Hazardous-area marking:
    [EEx ib] IIC
  • PTB test number:
    Ex-96.D.2026X
  • Required front connector:
    20-pin
  • Weight:
    0.411 kg
  • Estimated shipping dimensions:
    13.1x15.1x5.1cm
  • Tariff Code:
    85389091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Hazardous Signals Current Loop Review Ordering Check

Features:

  • Ex(i) outputs: Four isolated current outputs are intended for hazardous-area signals.
  • Current ranges: Each channel supports 0 to 20 mA or 4 to 20 mA.
  • Diagnostics: Wire break, overrange, group error, and channel fault diagnostics are documented.

Use this SM 332 where an S7-300 station must send four current signals into documented Ex(i) circuits.

Engineering review must include entity parameters, gas group, field load, cable shielding, and the 20-pin connector.

Do not substitute another SM 332 only by appearance; verify 5RD00, PTB test number, and the hazardous-area markings.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Siemens 6ES7332-5RD00-0AB0 SM 332 Ex(i) Analog Output Module Manuals,Datasheets,Link

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Siemens 6ES7332-5RD00-0AB0 SM 332 Ex(i) Analog Output Module Specs

General

  • ManufacturerSiemens
  • Model6ES7332-5RD00-0AB0
  • ConditionNew Original ready stock
  • Product FamilySIMATIC S7-300

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Ex marking: Confirm the documented [EEx ib] IIC circuit requirement.
  • Entity values: Review Uo, Io, Po, Co, and Lo against the connected circuit.
  • Approvals: Verify the PTB and applicable site approval requirements.
  • Range: Select 0 to 20 mA or 4 to 20 mA as required.
  • Load: Keep the current load within the official 500 Ohm maximum.
  • Diagnostics: Plan how wire-break and channel-fault indications will be handled.
  • Lifecycle: Siemens lists PM410 and product cancellation since 2025-10-01.
  • Suffix: Confirm 5RD00 rather than a standard voltage/current SM 332.
  • Connector: Include the required 20-pin front connector only when specified.
Description

Siemens 6ES7332-5RD00-0AB0 is an isolated SM 332 analog output module with four current outputs for signals from hazardous areas.

6ES7332-5RD00-0AB0 provides 0 to 20 mA and 4 to 20 mA ranges, 15-bit resolution, diagnostics, Ex(i) protection, and PTB test identification.

Confirm 6ES7332-5RD00-0AB0 by its 5RD00 suffix, 20-pin connector, hazardous-area design, and Siemens PM410 canceled-product status.

Alternative Names
Siemens 6ES7332-5RD00-0AB0 SIMATIC S7-300 6ES7332-5RD00-0AB0 6ES7 332-5RD00-0AB0 6ES73325RD000AB0 6ES7332-5RD00-0AB0 SM 332 6ES7332-5RD00-0AB0 Ex(i) Module SM 332 Hazardous-Area Analog Output S7-300 4 AO Current Output Module
Technical notes
Siemens 6ES7332-5RD00-0AB0 is the SM 332 Ex(i) Analog Output Module with 4 current outputs. Verify the complete order code and documented interface before installation or substitution.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can 6ES7332-5RD00-0AB0 be replaced by a standard SM 332 analog output module?
No direct substitution should be assumed. The 5RD00 version is documented for Ex(i) current circuits, so intrinsic-safety parameters, approvals, wiring segregation, connector details, and the complete safety documentation must remain compatible.
How are field-device entity parameters checked against 6ES7332-5RD00-0AB0?
Compare the documented output parameters Uo, Io, Po, Co, and Lo with the complete hazardous-area loop, including the field device and cable. The review must be performed under the site intrinsic-safety procedure.
Which current range should be configured on 6ES7332-5RD00-0AB0 for fault-aware loops?
Choose only the range required by the approved loop design. A 4–20 mA loop can support live-zero monitoring, while the diagnostic strategy must also account for wire-break, overrange, group-error, and channel-fault indications.
What should be checked if a 6ES7332-5RD00-0AB0 loop cannot reach the commanded current?
Check the 24 V DC supply, loop continuity, terminal assignment, configured range, and the documented 500-ohm maximum current-output load. Then review channel diagnostics before changing the module.
What installation controls apply to the 20-pin connector for 6ES7332-5RD00-0AB0?
Use the correct 20-pin connector and preserve the approved separation, identification, shielding, and routing of intrinsically safe circuits. Installation changes must be reflected in the hazardous-area loop documentation.
Why should the PTB identification be verified on 6ES7332-5RD00-0AB0 before purchase?
The PTB test identification and [EEx ib] IIC marking help confirm that the offered unit matches the documented hazardous-area configuration. A similar SM 332 label is not sufficient evidence.
What is essential when sourcing 6ES7332-5RD00-0AB0 as a canceled hazardous-area spare?
Request clear photos of the full MLFB, Ex marking, PTB identification, connector area, and condition. Preserve the validated loop calculation and site approval record because a different suffix may require a new engineering assessment.

Product Browsing History