Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports EA1*B identification, documentation review and quotation.

EA1*B

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa EA1*B accepts a 4 to 20 mA two-wire transmitter loop, supplies the field transmitter and produces two isolated 1 to 5 V DC outputs. It is used to condition powered process signals for CENTUM control inputs.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for EA1*B
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for EA1*B

  • Manufacturer:
    Yokogawa
  • Part Number:
    EA1*B
  • Product Family:
    Yokogawa DCS system
  • Product Type:
    Two-Wire Transmitter Input Card
  • Stock:
    1
  • Input signal:
    4 to 20 mA DC, two-wire transmitter
  • Input resistance:
    250 Ω
  • Transmitter supply:
    25 to 28 V DC
  • Supply current limit:
    25 to 35 mA
  • Output signal:
    1 to 5 V DC, two outputs
  • Isolation:
    Input/output/power/ground isolated
  • Card supply:
    24 V DC ±10%
  • Maximum current consumption:
    80 mA
  • Operating temperature:
    0 to 50 °C
  • Relative humidity:
    5 to 90% RH, non-condensing
  • Style code:
    B
  • Allowable input current:
    40 mA DC
  • External input resistance limit:
    RL = (20 − minimum transmitter operating voltage) / 0.02 Ω
  • Input linearization:
    None
  • Output resistance:
    1 Ω maximum
  • Minimum output load:
    2 kΩ
  • Accuracy rating:
    Within ±0.1% of span
  • Second-output accuracy:
    ±0.2% deviation from output 1
  • Isolation resistance:
    100 MΩ at 500 V DC between signal and power circuits
  • Input-to-output withstand voltage:
    1,500 V AC for 1 minute
  • Output-to-power withstand voltage:
    500 V AC for 1 minute
  • Ambient-temperature effect:
    Maximum ±0.2% of span per 10 °C change
  • Supply-voltage effect:
    Maximum ±0.1% of span for 24 V DC ±10%
  • Mounting method:
    Special signal-conditioner nest through backboard connector
  • Process wiring:
    M4 screw terminals in the signal-conditioner nest
  • Weight:
    0.154 lbs (0.07 kg)
  • Estimated shipping dimensions:
    7.3 x 2.4 x 11.5 cm
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Monitoring Connectivity Protection

Features:

  • Powers and measures a two-wire 4 to 20 mA transmitter loop.
  • Converts the loop current into two isolated 1 to 5 V DC outputs.
  • Limits the field-supply current to protect the connected loop.
The B-style card includes an integral transmitter supply as part of its ordered function.

It combines loop excitation, current sensing and isolated voltage reproduction on one conditioner channel.

Field polarity and the absence of a competing external supply must be confirmed before connection.

Apter Power can review sourcing, documentation and system matching for EA1*B.
Verified resources for Yokogawa EA1*B: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Pressure and differential-pressure transmitters can be powered and conditioned for the control system.
  • Flow, level and analytical instruments using two-wire loops can feed dual voltage destinations.
  • Legacy CENTUM cabinets can maintain established transmitter wiring through an exact-style card exchange.
  • The 250 ohm input converts the 4 to 20 mA loop current into a measurable internal signal.
  • Two voltage outputs reproduce the same process variable for separate receiving circuits.
  • A current-limited transmitter supply supports the field device and restricts fault energy.
  • The field side is wired as a powered two-wire current loop.
  • System-side outputs use the documented 1 to 5 V DC connections.
  • Shield and return conductors should follow the installed cabinet grounding practice.
  • The built-in field supply is limited between 25 and 35 mA.
  • Galvanic isolation separates input, outputs, power and ground domains.
  • Loop polarity checks prevent reverse connection of the transmitter electronics.
Description
EA1*B combines loop power and signal conversion for a two-wire 4 to 20 mA transmitter. Its 250 ohm input develops the measurement voltage while the card supplies the connected field device from a protected 25 to 28 V DC source.

The conditioned value appears on two 1 to 5 V DC outputs, allowing one process variable to feed separate system destinations. Galvanic separation keeps the field loop, outputs, power and ground from sharing an unintended current path.

Transmitter current demand, polarity and cable shield termination must be verified before connection. The card cannot be substituted blindly for an externally powered current-input conditioner because its loop-supply function changes the wiring arrangement.
Alternative Names
EA1*B Yokogawa EA1*B EA1 Star B EA1STARB EA1B EA1*B Two-Wire Transmitter Input Card Yokogawa CENTUM Signal Conditioner Cards Yokogawa EA1*B Two-Wire Transmitter Input Card
Technical notes
Observe loop polarity on Yokogawa EA1*B and never parallel an external transmitter supply with the card's protected 25 to 28 V source.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does Yokogawa EA1*B energize a field transmitter?
It provides a protected 25 to 28 V DC loop supply with a 25 to 35 mA current limit.
What system signals are available from Yokogawa EA1*B?
Two isolated 1 to 5 V DC outputs represent the incoming 4 to 20 mA measurement.
Which process instruments are appropriate for Yokogawa EA1*B?
Two-wire pressure, flow, level and analytical transmitters are typical applications.
How is Yokogawa EA1*B supply availability checked without relying on a generic family code?
Use the full EA1*B style identity and confirm the present card and cabinet interface at quotation time.
What wiring conflict must be avoided when replacing Yokogawa EA1*B?
Do not leave an external loop supply connected in parallel with the card's integrated transmitter source.
What loop information should accompany a Yokogawa EA1*B enquiry?
Provide transmitter type, loop polarity, existing terminal map, quantity and destination.