Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    The exact EJA530E-JAS4N-02CDL/NF2 configuration remains subject to nameplate and sourcing verification.

EJA530E-JAS4N-02CDL/NF2

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa EJA530E-JAS4N-02CDL/NF2 is an A-capsule gauge-pressure configuration with a stainless housing and NF2 intrinsic-safety approval for direct pressure monitoring and control in compatible process service.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for EJA530E-JAS4N-02CDL/NF2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for EJA530E-JAS4N-02CDL/NF2

  • Manufacturer:
    Yokogawa
  • Part Number:
    EJA530E-JAS4N-02CDL/NF2
  • Product Family:
    Yokogawa DCS system
  • Product Type:
    Gauge Pressure Transmitter
  • Stock:
    1
  • Measurement / Function:
    direct gauge pressure
  • Output / Command Signal:
    4–20 mA DC with digital communication
  • Communication / Control Interface:
    HART 5/HART 7 protocol
  • Selected Span / Torque Class:
    10 to 200 kPa (1.45 to 29 psi)
  • Configurable Range / Travel:
    -100 to 200 kPa (-14.5 to 29 psi)
  • Process / Pneumatic Connection:
    1/2 NPT female process connection
  • Wetted / Service Materials:
    316L SST process connector with Hastelloy C-276 diaphragm
  • Bolting / Mechanical Interface:
    Not applicable to direct-mount construction
  • Installation Arrangement:
    Direct-mount pressure connection
  • Housing:
    ASTM CF-8M stainless steel amplifier housing
  • Electrical Connection:
    1/2 NPT female, two entries with 316 SST blind plug
  • Local Indicator:
    Digital indicator
  • Mounting Hardware:
    316 SST 2-inch pipe bracket
  • Ordering Options:
    The /NF2 suffix specifies NEPSI Ex ia IIC T4 Ga intrinsic-safety approval for HART/BRAIN protocol types.
  • Degree of Protection:
    IP66/IP67, Type 4X
  • Ambient Conditions:
    -40 to 85°C (-40 to 185°F), or -30 to 80°C with LCD
  • Process / Service Temperature:
    -40 to 120°C (-40 to 248°F)
  • Communication Load / I/O:
    a total loop-load range of 0 to 1290 Ω, with 250 to 600 Ω required for digital communication
  • Stability / Control Performance:
    Stability ±0.1% of URL for 10 years
  • Manufacturer Reference:
    Yokogawa GS 01C31F01-01EN
  • Tariff Code:
    9026201090
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Interoperability Protection Efficiency

Features:

  • The stainless-housing intrinsic-safety configuration uses the 10 to 200 kPa (1.45 to 29 psi) capsule, direct-mount pressure connection and 1/2 NPT female, two entries with 316 SST blind plug.
  • The stainless-housing intrinsic-safety configuration provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator.
  • The stainless-housing intrinsic-safety configuration combines 1/2 NPT female process connection, 316L SST process connector with Hastelloy C-276 diaphragm and 316 SST 2-inch pipe bracket.
The supplied EJA530E-JAS4N-02CDL/NF2 variant is distinguished by A capsule code, stainless amplifier housing and NEPSI intrinsic-safety approval.

It converts gauge pressure into a control-system signal and supports configuration or diagnostic access through HART 5/HART 7 protocol.

Match stainless housing, NF2 entity parameters or approval temperature limits to the existing assembly before wiring, pressurization or actuator movement.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA530E-JAS4N-02CDL/NF2: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • The stainless-housing intrinsic-safety configuration measures liquid, gas or steam line pressure through a direct process-mounted connection.
  • The stainless-housing intrinsic-safety configuration supports pump, compressor, vessel or header pressure monitoring in an engineered control loop.
  • The stainless-housing intrinsic-safety configuration provides a primary pressure variable and diagnostic status for process control or asset monitoring.
  • Configuration tools must recognize the EJA530E DPharp EJA Series device description and the selected HART 5/HART 7 protocol signal type.
  • The analog loop remains available to a compatible control input while digital variables use the same pair of conductors.
  • Host alarm handling must be mapped to the transmitter diagnostics without overriding the plant trip philosophy.
  • The enclosure provides IP66/IP67, Type 4X protection only with all covers and cable-entry hardware fully secured.
  • Pressure containment depends on the specified 1/2 NPT female process connection and the chemical suitability of 316L SST process connector with Hastelloy C-276 diaphragm.
  • The /NF2 option specifies NEPSI Ex ia IIC T4 Ga intrinsic-safety approval for HART/BRAIN protocol types.
  • The two-wire 4–20 mA DC with digital communication loop combines power and measurement transmission while retaining HART 5/HART 7 protocol parameter access.
  • Remote setup and self-diagnostics reduce unnecessary enclosure opening during routine service activities.
  • The selected digital indicator supports local confirmation without adding a separate panel instrument where applicable.
Description
EJA530E-JAS4N-02CDL/NF2 is an order-code-specific EJA530E gauge pressure transmitter. Its mechanical, electronic and option selections include A capsule code, stainless amplifier housing and NEPSI intrinsic-safety approval.

It converts gauge pressure into a control-system signal and supports configuration or diagnostic access through HART 5/HART 7 protocol. The configuration is intended for direct pressure monitoring on compatible liquid, gas or steam lines when the process and installation limits are satisfied.

Do not approve a substitute from appearance or family name alone. Check stainless housing, NF2 entity parameters or approval temperature limits, the process connection and the installed loop documentation.
Alternative Names
EJA530E-JAS4N-02CDL/NF2 Yokogawa EJA530E-JAS4N-02CDL/NF2 EJA530E JAS4N 02CDL NF2 EJA530E-JAS4N-02CDL-NF2 EJA530EJAS4N02CDLNF2 Yokogawa EJA530E Gauge Pressure Transmitter Yokogawa EJA530E-JAS4N-02CDL/NF2 Gauge Pressure Transmitter Yokogawa DPharp EJA EJA530E-JAS4N-02CDL/NF2
Technical notes
Treat the NF2 marking as an installation constraint: the barrier, entity parameters, wiring and ambient limits must match the exact intrinsic-safety certificate.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What housing material is selected in EJA530E-JAS4N-02CDL/NF2?
The C housing code specifies an ASTM CF-8M stainless steel amplifier housing, paired here with stainless entry hardware and the selected /NF2 approval.
Which environmental hardware must preserve the enclosure protection of EJA530E-JAS4N-02CDL/NF2?
Use certified 1/2 NPT cable glands and the supplied 316 SST blind plug correctly, and maintain approved seals so the enclosure and intrinsic-safety installation remain valid.
Which corrosive-area pressure service may justify EJA530E-JAS4N-02CDL/NF2?
It can suit direct gauge-pressure monitoring where the stainless housing and selected wetted materials are compatible with the atmosphere and process, subject to the /NF2 installation rules.
What material verification should be requested for EJA530E-JAS4N-02CDL/NF2 stock?
Request nameplate and housing photographs plus written confirmation of the CF-8M housing and 316 SST blind plug before accepting the offered configuration.
Why is an aluminum-housing transmitter not automatically equivalent to EJA530E-JAS4N-02CDL/NF2?
Housing material changes corrosion behavior, weight, grounding and site acceptance, and may also differ in cable-entry hardware or approval marking.
Which corrosion and area data should accompany an EJA530E-JAS4N-02CDL/NF2 inquiry?
Provide process fluid, ambient contaminants, area classification and cable-gland plan, then request GS 01C31F01-01EN and the applicable /NF2 certificate with the quote.