PM5052-R-ETH 1SAP124100R0172

/ 4.9
1001 reviews | Need a Specific Revision?
PM5052-R-ETH 1SAP124100R0172: AC500-eCo CPU with relay outputs.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for PM5052-R-ETH 1SAP124100R0172
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PM5052-R-ETH 1SAP124100R0172

  • Manufacturer:
    ABB
  • Part Number:
    PM5052-R-ETH 1SAP124100R0172
  • Product Family:
    ABB AC500
  • Product Type:
    AC500-eCo CPU with relay outputs
  • Stock:
    1
  • ABB Article Number:
    1SAP124100R0172
  • Memory:
    4 MB
  • Integrated inputs:
    12 digital inputs, 24 V DC
  • Integrated outputs:
    6 relay outputs
  • Configurable channels:
    2 channels, 24 V DC
  • Ethernet interfaces:
    1
  • Weight:
    0.273 kg
  • Estimated shipping dimensions:
    8.2 x 13.5 x 7.4 cm
  • Tariff Code:
    85371091
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Relay Output Mapping Ethernet Commissioning I/O Expansion

Features:

  • AC500-eCo CPU with relay outputs for ABB AC500-eCo
  • Memory: 4 MB
  • Integrated inputs: 12 digital inputs, 24 V DC
The current ABB ordering configuration is PM5052-R-ETH 1SAP124100R0172, with 4 MB memory, twelve 24 V DC digital inputs, six relay outputs, two configurable channels, one Ethernet interface and three option slots.

Within an AC500-eCo installation, this processor combines controller execution, onboard digital I/O and Ethernet communication for compact distributed-automation applications.

Before installation, confirm relay-load ratings, 24 V DC field wiring, Ethernet addressing, option-module compatibility and the supported engineering-software and firmware versions.

Availability for PM5052-R-ETH 1SAP124100R0172 is subject to Apter Power stock and sourcing confirmation.
ABB PM5052-R-ETH AC500-eCo V3 Relay Processor Module Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

ABB PM5052-R-ETH 1SAP124100R0172 Specifications

General

  • ManufacturerABB
  • ModelPM5052-R-ETH 1SAP124100R0172
  • ConditionNew Original ready stock
  • Product FamilyABB AC500-eCo V3
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Output technology: Six integrated relay outputs are documented for this CPU.
  • Field load review: Verify the connected load against ABB relay-output ratings.
  • Channel assignment: Map every output in the AC500-eCo project before commissioning.
  • Network port: One integrated Ethernet interface is provided.
  • Address plan: Assign the controller address to match the plant network design.
  • Project check: Confirm the engineering project and firmware release before download.
  • Onboard I/O: Twelve digital inputs, six relay outputs, and two configurable channels are integrated.
  • Option capacity: Three option slots are available.
  • Expansion review: Select expansion hardware from the compatible AC500-eCo range.
Description
PM5052-R-ETH 1SAP124100R0172 is a compact ABB AC500-eCo V3 PLC CPU that combines processing, 12 digital inputs, six relay outputs, two configurable 24 V DC channels, one Ethernet interface, and three option-board slots in one module.

Its relay outputs suit compact machine and utility controls that must switch isolated loads without separate transistor output modules. The 7 MB maximum downloadable application size and expandable option slots support practical control, communication, and local I/O growth while keeping cabinet hardware focused.

Select revision 1 only after checking the Automation Builder target, relay contact ratings, inductive-load suppression, 24 V DC supply, option boards, and the validated project backup.
Alternative Names
PM5052-R-ETH 1SAP124100R0172 PM5052-R-ETH 1SAP124100R0172 ABB PM5052-R-ETH PM5052-R-ETH controller ABB AC500-eCo V3 PM5052-R-ETH
Technical notes
Deploy PM5052-R-ETH revision 1 only with an Automation Builder target that supports 1SAP124100R0172. This 24 V DC CPU provides 12 inputs, six relay outputs, one Ethernet port and three option slots; verify relay inrush, inductive-load suppression and the TA5212 terminal set before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When should PM5052-R-ETH be chosen instead of the transistor-output PM5052 version?
Choose PM5052-R-ETH only when the engineered AC or DC loads, isolation needs, inrush, and switching duty suit relay contacts; otherwise review the transistor version.
Can PM5052-R-ETH 1SAP124100R0172 replace the earlier R0072 revision without validation?
Do not assume a drop-in change. Confirm Automation Builder support, project target, fast-channel behavior, terminals, firmware, and the complete acceptance test.
Why can a PM5052-R-ETH relay click while the field device remains off?
Check field power, contact terminals, common wiring, fuse, load continuity, suppression components, and voltage at the device before replacing the CPU.
Which terminal set should be checked for PM5052-R-ETH installation?
Confirm an ABB-approved TA5212-TSCL or TA5212-TSPF set, the required connection technology, conductor sizes, and the actual package scope.
How should PM5052-R-ETH option boards be selected?
Match each board to the exact CPU revision, firmware and engineering version, slot availability, electrical interface, current demand, and application requirement.
What should be backed up before changing a PM5052-R-ETH CPU?
Save the validated project, firmware record, retained-data plan, Ethernet parameters, option-board settings, I/O map, and tested restoration procedure.
How should PM5052-R-ETH configurable fast channels be commissioned?
Verify channel mode, field reference, pulse parameters, connected load, project mapping, and safe-state behavior under controlled test conditions.