Features:
- Compact controller architecture: Local control and network duties are combined without requiring a separate basic I/O assembly.
- Dual-network planning: Two Ethernet connections let engineers document service and plant-network roles separately.
- Configurable expansion: Option-board positions allow the approved communication or local-function scope to be matched to the machine.
PM5082-T-2ETH 1SAP124600R0173 suits compact machines where controller, local I/O and Ethernet responsibilities must be coordinated in one AC500-eCo station.
Commissioning should separate network roles, document every option board and test the intended fast-channel functions with the connected devices.
A controlled replacement plan preserves the project archive, firmware record, terminal map, network settings and machine acceptance results.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB PM5082-T-2ETH 1SAP124600R0173 AC500-eCo V3 Pro CPU PLC Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB PM5082-T-2ETH 1SAP124600R0173 AC500-eCo V3 Pro CPU PLC Specs
General
- ManufacturerABB
- ModelPM5082-T-2ETH 1SAP124600R0173
- ConditionNew Original ready stock
- Product FamilyABB AC500-eCo V3
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Engineering baseline: Use Automation Builder 2.6.0 or later.
- Firmware floor: Keep BootFW and CPUFW at V3.6.x or later.
- Mixed hardware: Apply ABB firmware rules when earlier CPU revisions remain in one project.
- Recovery: Retain the validated archive and rollback procedure.
- Interface map: Assign each port a documented engineering or control duty.
- Address plan: Check subnets, gateways and duplicate addresses before startup.
- Switch path: Verify cabling and managed-switch settings with the final topology.
- Security: Enable only the services permitted by plant policy.
- Terminal set: Match the removable power and I/O terminals to the ordered scope.
- Option boards: Validate every board and slot against the exact CPU revision.
- Fast channels: Confirm counter, encoder or pulse duties in the approved design.
- Acceptance: Test local I/O and each expansion function independently.