Features:
- Higher project capacity: The controller is intended for more demanding compact applications than the lower PM50xx Pro configuration.
- Integrated machine interface: Onboard signals and configurable channels support local machine functions without a separate basic I/O layer.
- Structured Ethernet use: Two ports support a documented separation of engineering and operational traffic.
PM5092-T-2ETH 1SAP124700R0173 is suited to compact machines whose program, visualization or communication demand needs more growth margin within the AC500-eCo platform.
Actual capacity should be checked with the compiled project, enabled services, connection count and worst-case task activity rather than by model class alone.
Before release, verify the terminals, option boards, network design, firmware and recovery procedure against the final bill of materials.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB PM5092-T-2ETH 1SAP124700R0173 AC500-eCo V3 Pro CPU PLC Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB PM5092-T-2ETH 1SAP124700R0173 AC500-eCo V3 Pro CPU PLC Specs
General
- ManufacturerABB
- ModelPM5092-T-2ETH 1SAP124700R0173
- ConditionNew Original ready stock
- Product FamilyABB AC500-eCo V3
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Compiled project: Measure code, data and visualization use after final build.
- Connections: Include protocol sessions and diagnostic services in the load test.
- Growth reserve: Keep documented margin for approved machine changes.
- Evidence: Archive accepted resource and timing results.
- Port purpose: Assign each Ethernet interface one approved role.
- Segmentation: Keep control and service traffic in the documented architecture.
- Access: Restrict engineering and web services to authorized hosts.
- Recovery test: Verify communication returns correctly after link interruption.
- Source archive: Preserve the original application before conversion.
- Target device: Select the exact R0173 CPU in the project.
- Firmware set: Follow ABB requirements for every CPU in a mixed-revision application.
- Validation: Repeat I/O, task, network and machine-safety tests.