Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    ABB lists PM582 as Classic; Apter Power supports quotations, lifecycle planning, documentation, and system matching.

PM582

/ 4.9
1001 reviews | Need a Specific Revision?
ABB PM582 is a 512 kB AC500 processor with dual configurable serial interfaces, FBP, display, and memory-card support.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for PM582
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PM582

  • Manufacturer:
    ABB
  • Part Number:
    PM582
  • Product Family:
    ABB AC500
  • Product Type:
    AC500 Processor Module
  • Stock:
    1
  • Program Memory:
    512 kB
  • Supply Voltage:
    24 V DC
  • Serial Interfaces:
    2 configurable RS-232/485
  • FBP Interface:
    1
  • Display:
    Integrated
  • Memory Card:
    Supported
  • ABB Lifecycle:
    Classic
  • Weight:
    0.135 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Communication Plan Memory & Tasks Lifecycle Planning

Features:

  • 512 kB program capacity: Supports AC500 applications within the documented memory.
  • Two configurable serial ports: Each interface can be matched to the approved RS-232/485 role.
  • Fieldbus and recovery resources: FBP, display, and memory-card support aid system integration.
PM582 supplies the controller execution and communication resources for established AC500 applications that fit its 512 kB program capacity.

The exact project, serial-port modes, FieldBusPlug configuration, and expansion design determine whether a replacement will restore operation correctly.

Prepare a verified backup and commissioning checklist before exchange, especially when legacy serial devices or fieldbus nodes are production-critical.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
PM582 Manuals, Datasheets, and Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
PM582 AC500 Processor Module Specifications

General

  • ManufacturerABB
  • ModelPM582
  • ConditionNew Original ready stock
  • Product FamilyABB AC500
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Serial and fieldbus records

  • COM assignments: Document both port roles and protocols.
  • Electrical mode: Confirm RS-232 or RS-485 wiring.
  • FBP network: Save addressing and connected-node details.
  • Cables: Label connectors, shields, and termination.

Application-capacity review

  • Program size: Confirm the project fits 512 kB.
  • Cycle behavior: Record timing and task requirements.
  • Retained data: Preserve values required after restart.
  • Backup: Verify project and memory-card recovery.

Classic-product support strategy

  • Installed base: Record CPU, terminal base, and expansion modules.
  • Spares: Define tested hardware and documentation scope.
  • Compatibility: Compare firmware and project dependencies.
  • Modernization: Maintain a staged upgrade and rollback plan.
Description
PM582 is an ABB AC500 processor with 512 kB program memory, 24 V DC operation, two configurable RS-232/485 interfaces, an FBP interface, a local display, and memory-card support.

PM582 provides more program capacity than PM57x members while retaining the serial and fieldbus resources used in established AC500 architectures. ABB currently lists the product in its Classic lifecycle phase.

Before procuring PM582, verify the application size, terminal base, firmware and project versions, both serial-port configurations, FBP network, memory-card procedure, and installed expansion hardware.
Alternative Names
PM582 ABB PM582 PM 582 PM-582 ABB PM582 AC500 AC500 PM582
Technical notes
PM582 is a 512 kB AC500 processor with two configurable serial interfaces, FBP, display, and memory-card support. Verify project size, terminal base, and communications.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should PM582 be matched to an existing AC500 controller system?
Verify the exact CPU, terminal base, firmware, Automation Builder project, communication interfaces, expansion hardware, and 512 kB program capacity and serial/FBP resources.
What should be saved before replacing PM582?
Back up the verified application, retained data, communication parameters, firmware record, memory-card contents, I/O map, and commissioning results.
Why might PM582 remain out of run after installation?
Check the 24 V DC supply, terminal-base seating, compatible firmware, downloaded project, operating state, communication modules, and controller diagnostics.
How should PM582 serial communication be recommissioned?
Confirm RS-232 or RS-485 mode, protocol, baud rate, address, polarity, shielding, termination, and each connected device.
What should a buyer provide when requesting a PM582 quotation?
Include terminal base, project size, firmware, COM settings, FBP network, memory card, and expansion layout, full nameplate photos, quantity, required condition, destination, and requested delivery date.
Can PM582 replace another AC500 CPU without project review?
Do not assume interchangeability; compare memory, terminal base, interfaces, FBP use, firmware, expansion, and the approved control application.
How can engineers shorten PM582 commissioning time?
Prepare the verified project, label every connection, record network settings, define safe I/O tests, and keep the previous controller available for rollback.