Technical specifications for PM851K01 3BSE018168R1

  • Manufacturer:
    ABB
  • Part Number:
    PM851K01 3BSE018168R1
  • Product Family:
    ABB Advant AC800M
  • Product Type:
    Processor Unit Kit
  • Stock:
    1
  • Processor clock:
    24 MHz
  • Memory:
    PM851 CPU, TP830, TB850, TB807 and backup battery
  • Package contents:
    PM851/PM851A CPU, TP830, TB850, TB807 and backup battery
  • Software license:
    Not included
  • Weight:
    1.1 kg
  • Estimated shipping dimensions:
    13.5 x 11.9 x 18.6 cm
  • Tariff Code:
    85389091
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Project Fit Review Successor Planning Kit Receiving Check

Features:

  • Brownfield controller support: The exact legacy kit helps maintenance teams control an installed AC 800M configuration.
  • Package-level procurement: CPU and required base accessories are checked as one service item.
  • Successor-aware planning: ABB replacement information is treated as a migration decision requiring project validation.
PM851K01 purchasing starts with the running project and cabinet record, not only the CPU label.

A qualified offer should state which kit components are included and whether the unit is unused, refurbished or exchanged.

Engineering and lifecycle decisions are separated from the numeric data in Technical specifications.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

ABB PM851K01 3BSE018168R1 Processor Unit Kit Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

ABB PM851K01 3BSE018168R1 Processor Unit Kit Specs

General

  • ManufacturerABB
  • ModelPM851K01 3BSE018168R1
  • ConditionNew Original ready stock
  • Product FamilyAC 800M Processor Units

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Archive validation: Open the latest project in the correct engineering release.
  • Capacity evidence: Review real application loading and planned changes.
  • Hardware tree: Compare configured interfaces and I/O with the installed system.
  • Replacement scope: Treat the ABB successor as a new controlled baseline.
  • Toolchain: Check engineering-version and firmware support before the outage.
  • Acceptance plan: Define communication, I/O and process tests with rollback criteria.
  • Component labels: Match the CPU, base and terminators against the offer.
  • Battery status: Check presence, date and handling before installation.
  • License boundary: Keep hardware supply separate from software entitlement.
Description
The ABB PM851K01 3BSE018168R1 is a processor-unit kit used in earlier AC 800M controller installations and is supplied as a defined CPU, baseplate, terminator, and backup-battery package.

The ABB PM851K01 3BSE018168R1 is most relevant to brownfield maintenance where project size, engineering release, firmware, communication scope, and the original hardware tree are already known.

Before ordering ABB PM851K01 3BSE018168R1, confirm the installed CPU label, kit completeness, current project archive, supported replacement path, and whether the plant accepts migration to ABB's identified successor.
Alternative Names
PM851K01 3BSE018168R1 ABB PM851K01 3BSE018168R1 PM851K01 PM851K01-3BSE018168R1 3BSE018168R1 PM851 K01 AC 800M PM851K01
Technical notes
ABB marks this article as no longer for sale and identifies 3BSE066485R1 as the replacement. Treat migration as an engineered change, not a drop-in assumption.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can ABB PM851K01 be replaced by ABB's identified successor without converting the project?
Do not assume a direct swap. Review the engineering release, firmware, hardware tree, application conversion messages and site acceptance requirements first.
What evidence is needed to qualify ABB PM851K01 for an installed control cabinet?
Provide the CPU and base labels, project version, firmware record, connected communication hardware, I/O topology and clear photographs of the complete assembly.
Why might an ABB PM851K01 replacement start but leave field I/O unavailable?
Check the restored hardware tree, bus termination, module addressing, controller diagnostics, power and firmware compatibility before isolating a component.
How should a plant prepare a short outage for ABB PM851K01?
Validate the archive, document controller identity and connections, stage all kit parts, define rollback and obtain process-owner approval for the test sequence.
Can a used ABB PM851K01 be accepted only because it powers on?
No. Require traceable condition evidence and verify diagnostics, project loading, communication, I/O behavior and the site acceptance plan.
What should a trader clarify when quoting ABB PM851K01 as a complete kit?
List every included CPU, base, terminator, battery and plug item explicitly, plus condition and test evidence, so the buyer can identify shortages before shutdown.
How can engineers investigate repeated restart events involving ABB PM851K01?
Correlate controller logs with power quality, battery condition, base connections, firmware, communication loading and recent project changes before replacing hardware.

Product Browsing History