Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, version checks, synchronization review, and PM862 package matching.

PM862K02 3BSE081636R1

/ 4.9
1001 reviews | Need a Specific Revision?
ABB PM862K02 3BSE081636R1 is a redundant 67 MHz, 32 MB AC 800M processor package with two PM862 CPUs, two TP830 baseplates, and link hardware.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for PM862K02 3BSE081636R1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PM862K02 3BSE081636R1

  • Manufacturer:
    ABB
  • Part Number:
    PM862K02 3BSE081636R1
  • Product Family:
    ABB Advant AC800M
  • Product Type:
    Redundant Processor Unit Kit
  • Stock:
    1
  • Article Number:
    3BSE081636R1
  • Package Configuration:
    Redundant K02 kit
  • Controller Version:
    PM862
  • Redundancy:
    Yes
  • High Integrity:
    No
  • Clock Frequency:
    67 MHz
  • Memory per CPU:
    32 MB
  • Application RAM per CPU:
    23.521 MB
  • Flash Storage:
    Yes
  • Processor Type:
    MPC866
  • Switch-Over Time:
    Maximum 10 ms
  • Power Supply:
    24 V DC (19.2-30 V DC)
  • Current per CPU:
    210 mA typical; 360 mA maximum
  • Typical Dissipation per CPU:
    5.1 W
  • Ethernet per CPU:
    2 channels
  • Serial Channels per CPU:
    2 RS-232C
  • CEX-Bus Capacity:
    12 communication modules
  • Software Baseline:
    800xA 6.0.2 or Compact Control Builder 6.0.0-1 and later
  • Official Kit Scope:
    2 PM862, 2 TP830, 2 TB807, TK850, TB851, 2 batteries; no license
  • Weight:
    2.7 kg
  • Estimated shipping dimensions:
    CPU dimensions (each): 11.9 x 18.6 x 13.5 cm.
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Pair Matching Version Baseline Sync Checks

Features:

  • Matched redundant package: The K02 order includes two CPUs, baseplates, terminators, link cables, and memory-backup batteries.
  • PM862 performance tier: Each controller provides the official 67 MHz and 32 MB resource profile.
  • Version-controlled deployment: ABB specifies a minimum 800xA or Compact Control Builder baseline for this processor generation.

PM862K02 serves AC 800M projects requiring PM862 controller redundancy and the matching K02 hardware bundle.

The two CPUs operate with the documented RCU and CEX links, while Ethernet, serial, communication, and I/O assignments remain project-specific.

A controlled replacement should preserve firmware, application files, CN1/CN2 settings, serial-port roles, CEX modules, I/O mapping, and redundancy acceptance records.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

ABB PM862K02 3BSE081636R1 Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

ABB PM862K02 3BSE081636R1 Redundant Processor Unit Kit Specs

General

  • ManufacturerABB
  • ModelPM862K02 3BSE081636R1
  • ConditionNew and factory sealed
  • Product FamilyAC 800M Controllers

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

PM862 redundant pair checks

  • CPU identity: Confirm two PM862 units with compatible hardware and firmware.
  • Baseplates: Verify both TP830 assemblies and installed terminations.
  • Cables: Match TK850 and TB851 to the approved cabinet layout.
  • Batteries: Inspect both memory-backup batteries under the maintenance plan.

Engineering release review

  • 800xA: Use release 6.0.2 or a supported later version.
  • Compact Builder: Use 6.0.0-1 or a supported later release.
  • Firmware: Match the project-approved controller firmware.
  • Project restore: Compile and validate the application in the approved environment.

Redundancy commissioning sequence

  • Primary state: Confirm the designated active controller and diagnostics.
  • Backup state: Verify synchronized backup status before service.
  • Communications: Test both network paths and connected interfaces.
  • Switchover: Record controlled failover and return-to-service results.
Description
ABB PM862K02 3BSE081636R1 is the redundant PM862 processor package. ABB lists two PM862 CPUs, two TP830 baseplates, two TB807 ModuleBus terminators, one TK850 CEX-bus cable, one TB851 RCU-Link cable, and two backup batteries; no license is included.

PM862K02 3BSE081636R1 provides 67 MHz processing and 32 MB RAM per CPU with flash storage, two Ethernet ports, two RS-232C ports, and support for controller redundancy in the documented AC 800M architecture.

Before ordering PM862K02 3BSE081636R1, verify System 800xA 6.0.2 or Compact Control Builder 6.0.0-1 and later, both controller labels, link hardware, firmware, I/O tree, and application backup.
Alternative Names
PM862K02 3BSE081636R1 PM862K02-3BSE081636R1 PM862K02 3BSE 081636 R1 PM862K023BSE081636R1 ABB PM862K02 3BSE081636R1 Asea Brown Boveri PM862K02 ABB AC 800M PM862K02 PM862K02 Redundant Processor Unit Kit
Technical notes
PM862K02 3BSE081636R1 is the redundant PM862 package for supported 800xA and Compact Control Builder releases. Match both CPUs, baseplates, terminators, cables, batteries, and firmware.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What project evidence is needed before selecting PM862K02 3BSE081636R1?
Provide the 800xA or Compact Control Builder release, firmware, application load, communication tree, I/O design, and redundancy requirement.
How does PM862K02 3BSE081636R1 differ from the PM862K01 package?
K02 is the documented redundant bundle with two CPUs and link hardware; K01 is the separate single-controller package.
What should be checked when receiving PM862K02 3BSE081636R1?
Verify two PM862 CPUs, two TP830 baseplates, two TB807 terminators, TK850, TB851, two batteries, and nameplate traceability.
Why might PM862K02 3BSE081636R1 remain in a non-synchronized state?
Check controller firmware, application state, RCU and CEX cabling, Control Network identity, diagnostics, and approved redundancy settings.
How should engineers migrate an older controller application to PM862K02 3BSE081636R1?
Confirm software support, compile the project, preserve communication and I/O configuration, validate backups, and perform a controlled factory or site test.
What installation records should accompany PM862K02 3BSE081636R1?
Keep cabinet drawings, power design, grounding, network addresses, serial assignments, cable routing, firmware, and failover test results.
What should procurement include in a PM862K02 3BSE081636R1 RFQ?
Send both installed nameplates, required package scope, software version, quantity, condition, destination, and delivery target.
What should be investigated if PM862K02 3BSE081636R1 loses communication after switchover?
Review both Ethernet paths, switch configuration, CN identities, communication-module status, application diagnostics, and redundancy event logs.